Megger PAT120 PAT Tester 1003-062
- Fast report generation
- Automatic Test Sequences
- Battery Powered
- Automatic Test Sequences
- Battery Powered
- Croc-clips and Probes Included
- Hand-held
- Hard Case Included
- Pass and Fail Labels Included
- Software Included
For a limited time ISSWWW are offering you FREE quality PAT accessories with purchases of selected
PAT testers and PAT testing kits. Simply make your selection from the drop down box below to add your bundle.
*Choose from the following:
-
Option 1) Kewtech PATLOG1 PAT Register & a set of 500 PASS and 200 FAIL labels
-
Option 2) Seaward 270A076 110V PAT adapter
-
Option 3) Kewtech KT111 fully auto-ranging Multimeter
-
Option 4) Kewtech 103 Audible Socket Tester and a Kewtech R2 Socket Testing Adapter
Megger PAT120 PAT Tester 1003-062
Hand-held battery operated portable appliance tester
Key Features:
- Simple tick or cross, pass or fail indication plus measurement
- Tough, rubber armoured with built-in front cover, hardened, scratch-proof display window
- Includes 250 V insulation and leakage testing for safe IT testing and surge protected devices
- Testing portable and fixed electrical equipment
- 10 mA and 30 mA portable RCD lead testing (PAT150)
- Adjustable PASS test limits (PAT150)
- Substitute and mains powered leakage testing (PAT150)
- Battery powered with rechargeable options
The PAT100 series of hand-held portable appliance testers enable simple, fast safety testing in all environments including offices, shops and business units. It is ideally suited to training organisations, easy to learn to use, tough and reliable yet with full functionality.
With rubber armoured cases and fitted with hardened, scratch proof glass, the PAT100s are exceptionally tough instruments, well able to cope with the treatment they will encounter on site or in the van. They are the perfect tester to carry just in case your customers ask "Could you just test..."
There are 3 testers in the range:
PAT120 simple PAT tester offer Class I, Class II and power and extension lead testing with fixed pass limits; because it has two insulation test voltages it can be used to test IT and surge protected equipment.
PAT150 full functionality PAT tester adds to the offering Portable RCD (PRCDs) testing at 10 mA and 30 mA, separate tests for continuity, insulation, mains powered leakage testing and SELV measurements using the quick test (QT) button, and can be used for testing fixed appliances.
PAT150R is a rechargeable version of the PAT150.
The PAT100 series of hand-held portable appliance testers enable simple, fast safety testing in all environments including offices,
shops and business units. It is ideally suited to training organisations with a very short learning curve and tough, reliable functionality.
With rubber armoured cases and fitted with hardened, scratch proof glass, the PAT100s are exceptionally tough instruments.
Battery powered operation makes the PAT100s perfect for those locations where an electrical supply is not available, inconvenient or
unsafe, especially building sites and warehouses. The PAT100 series conforms to all UK and European requirements for electrical safety testing.
Test groups
Test groups enable the correct sequence of tests to be performed automatically with minimum intervention by the user. This keeps
testing simple, reduces test times to a minimum and helps to prevent testing errors.
PAT120:
■ The PAT120 model has test groups available for Class I, Class II and Extension/Power leads.
■ Fixed PASS limits.
■ Insulation testing at 500 V (default) or 250 V can be selected at the start of the test.
■ Leakage testing uses a “Substitute Leakage” also known as the “Alternative” method to remove the need for a mains supply during test.
The PAT150:
■ The PAT150 has additional tests available for testing portable RCDs (PRCDs) of 10 mA and 30 mA.
■ Separate tests for continuity, insulation, mains powered leakage testing and SELV measurements can be made using the Quick Test (QT) button.
■ Test group pass limits and test duration can be configured by the user.
■ Bond lead resistance can be nulled to reduce measurement errors.
■ Live circuit measurement is available for testing the mains supply and socket polarity or electrical circuit voltage to 300 V ac.
■ Can be used for testing fixed appliances.Continuity test Used for measuring the proper bonding of all metal parts of a class I device to the protective conductor.
Key Features | Fast report generation, Automatic Test Sequences, Battery Powered | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Megger | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
|
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA
-
This Item:
£491.99
-
Fluke T6-1000 Electrical Tester with FieldSense
£275.94