Like most organisations we use cookies on our site, these allow us to improve your experience on our site, provides us with measurement and analytical data, and allows us to make use of the latest digital marketing capabilities - if you want to know more about cookies and how you can control them see our cookie policy here, if you are happy for us to use cookies then please click the button opposite.
The images provided are for illustrative purposes only. Please refer to product description.

Megger MFT1735 Multifunction Tester

17th Edition Total Solutions Multifunction Tester with download and Bluetooth functionality, rechargeable batteries and earth spike set

Next Day Delivery (subject to availability)

£1,056.00 including VAT @ 20% £880.00 excluding VAT Regular Price: £1,782.00
  • Bluetooth Connectivity
  • Manufacturer Certificate Included
  • Phase Rotation Service
  • Earth Testing
  • Downloadable
  • Auto RCD
  • 2 Wire Loop test
  • Backlit LCD Display
  • Non Trip Loop Testing
  • Memory Function
  • FreeDelivery
  • 30DayMoneyBack
Required Fields
  • Description
  • Features & Specification
  • Resources
  • Delivery

 

Free Gift For Multifunction Testers

 

MFT1735 designed for testing low voltage electrical installations to BS 7671. It provides all the tests required to complete the necessary electrical certification for industrial, commercial and domestic fixed wiring installations. Supplied with rechargeable batteries and earth spike set.


Megger MFT1735 Comes Supplied With: 

  • Printed quick start guide Full user guide on CD 
  • Calibration certificate 
  • Switched probe SP5 (not with MFT1710) 
  • 1002-774 Neck strap - Megger embroidered 2001-509 
  • 3 Wire lead set with prods and clips 
  • 1001-991 SIA10 Socket interface adaptor UK to 3 x 4 mm (BS) 
  • 6220-810 SIA20 Socket interface adaptor UK to 3 x 4 mm (AU) 
  • 6220-828 Plug-in battery charger 2001-697. 
  • Rechargeable Batteries 
  • Earth spike set.


 

The MFT1700 series is a range of 3 instruments for testing low voltage electrical installations to BS7671. They provide all the tests required to complete the necessary electrical certification for industrial, commercial and domestic fixed wiring installations. 

The unique modern styling allows it to be operated while stood on the floor, a ladder-shelf or platform, hung around the neck or handheld. Dual TEST and LOCK buttons – one pair at each end – makes the testers easy to operate left or right handed. 

Quick to pick up and use, the controls are colour coded to make range selection easy and fast. They also reduce the chance of using the wrong function or range. The large crystal clear backlit display uses the patented Megger digital/analogue arc, providing indication of fluctuating readings while the dual digital readout shows precise values of key measurements simultaneously with the test parameters, such as the output voltage on insulation testing as well as the resistance value in MΩ.

Visible and audible safety warnings are paramount when testing high-energy systems and the MFT1700 series includes full input protection and safety warnings when a hazardous voltage is present. If live voltages exist on a circuit during insulation or continuity testing, the voltage is displayed on the screen.If this voltage exceeds a safe level, further testing is inhibited and a warning beep sounds.

The MFT1730 features internally rechargeable batteries and charger with a charge time of less than 4 hrs, so reducing the cost of ownership. Fully compliant with all requirements of IEC 60364 derived standards including VDE 0100 and BS 7671, the new MFT includes all the latest measurement technology in a lightweight

 

Key Features:

  • Two wire non trip loop testing for fast repeatable results

  • On-board data storage and Bluetooth® download

  • 3-terminal earth test for electrode resistance measurement

  • 3-phase RCD testing for industrial applications with no earth

  • Phase rotation indication for verification of rotating machinery

  • Large bright LCD display showing dual parameters - loop resistance and fault current, insulation resistance and test voltage

SPECIFICATIONS

Insulation test

Output voltage -0% +20% at rated load or less

Voltage display ±3% ±3 digits ±0.5% of rated voltage

Short circuit current 1.5 mA nominal test current

Test current on load 1 mA at min pass values of insulation

Measurement accuracy

1000 Volts 10 kΩ ~ 999 MΩ ±3% ±2 digits

500 Volts 10 kΩ ~ 500 MΩ ±3% ±2 digits

 >500 MΩ ±10% ±4 digits

250 Volts 10 kΩ ~ 250 MΩ ±3% ±2 digits

 >250 MΩ ±10% ±4 digits

100 Volts 10 kΩ ~ 100 MΩ ±3% ±2 digits

 >100 MΩ ±10% ±4 digits

Continuity / resistance

 0.01 Ω ~ 99.9 Ω ±2% ±2 digits

 100 Ω ~ 99.9 kΩ ±5% ±2 digits

Open circuit voltage 5 V ±1 V

Test current (0 Ω ~ 2 Ω) 205 mA ± 5 mA

 15 mA ±5 mA (user selectable)

 

Loop test

Live to earth supply 48 V ~ 280 V (45 Hz ~ 65 Hz)

Live to live supply 48 V ~ 500 V (45 Hz ~ 65 Hz)

L-N/L-L tests ±5% ±3 digits

L-E tests*

0.1 Ω ~ 39.9 Ω ±5% ±5 digits ± noise margin

40.0 Ω ~ 999 Ω ±10% ±5 digits

Display range 0.01 Ω ~ 999 Ω

Live to earth PFC range 20 kA

Live to live PSCC range 20 kA

Rcd tests

Supply up to 100 mA 48 V ~ 480 V (45 Hz ~ 65 Hz)

Supply up to 1 A 48 V ~ 280 V

RCD type Type AC, A, S

 Type B (pure dc)

No trip test (1/2xI) –10% ~ –0%

Trip test (1xI & 5xI) +0% ~ +10%

Ramp test

Touch voltage (0 ~ 253 V) +5% +15% ±0.5 V

Trip time ±1% ±1 ms

Trip current ±3%

Step increments

VAR (variable RCD selection) 10 mA ~ 50 mA 1 mA steps

 50 mA ~ 500 mA 5 mA steps

 500 mA ~ 1000 mA 10 mA steps

Supply measurement

Voltage 10 V ~ 600 V (15 ~ 400 Hz) True

 RMS

 ±3% ± 1 V ±2 digits

Phase rotation indication L1–L2–L3 & L1–L3–L2

Frequency 15 Hz ~ 99 Hz ±0.5% ±1 digit

 100 Hz ~ 400 Hz ±2.0% ±2 digits

Frequency resolution 0.1 Hz

Power

MFT1735: 1.2 V NiMH (rechargeable 6 cells supplied)

 Mains charger for on-board  re-charging (4 hours typical)

 12 V car charger (cigar lighter lead  - optional)

Earth test

Resolution 0.01 Ω

Current 0.45 mA or 4.5 mA

Noise rejection 20 V pk/pk (7 V rms).

Max probe resistances Rp & Rc

 100 kΩ @ 50 V

 5 kΩ @ 25 V

2 & 3 pole method (0.01 Ω ~ 1.999 kΩ)

 ±2.0% ±3 digits

ART method (1.00 Ω ~ 1.999 kΩ) ±5.0% ±3 digits**

Stakeless method (1.00 Ω ~ 199 Ω) ±7.0% ±3 digits**

Current (via optional clamp meter)

 ±5.0% ±3 digits.

Range 0.1 mA to 200 A ac

Resolution 0.1 mA

mV Sensor input

including temperature (third party module)

 ±1.0% ±2 digits

Range 0.0 mV to ±199.9 mV dc

Resolution 0.1 mV

Internal memory (MFT1735)

Capacity 1000 results

Bluetooth communication

Design standards

Safety

IEC 61010-1:2010

IEC 61010-30:2010

IEC 61010-031:2008

600 V Cat III / 300 V Cat IV (Max Phase to Phase 600 V)

IEC 61557:2007 parts 1 to 10

EMC

IEC61326 edition 2 location class B

For test environments see service data.

Environmental

Temperature (operational) -10 °C ~ +55 °C

Temperature (storage) -25 °C ~ +70 °C

Operating humidity 90% R.H. at +40 °C max

Max altitude 2000 m

Weight 1 kg (with batteries, excluding case)

Dimensions: 150 mm H x 85 mm W x 235 mm D

Moisture/dust ingress protection IP54

Calibration temperature: +20 °C

Temperature effects

Temperature coefficient: <0,1% per °C

Standard FREE 3-5 Day Courier Delivery – UK Mainland only - Zones A & B
Included in the price for all orders over £40.00 (exc vat). Sent using express courier, delivered within 3-5 working days from the date of your order, subject to availability.

Standard 1-2 Day Express Courier Delivery – UK Mainland only - Zones A & B
£4.50 for all all orders under £40.00 (exc vat). Sent by express courier, delivered within 1-2 working days from the date of your order, subject to availability.

Express Courier 1-2 Day Delivery – UK Mainland only - Zones A & B
£4.50 select at the checkout. Sent using express courier.

Next Day Delivery – UK Mainland only - Zones A & B
£8.00 select at the checkout. Sent using express courier, orders must be placed before 3pm for next day delivery, subject to availability.

Saturday Pre 12am - UK Mainland only - Zones A & B
£15.00 select at the checkout. Sent using express courier, orders must be placed before 3pm for Saturday delivery.

Orders must be placed before 3pm for next day delivery and a telephone number supplied, subject to availability.
Please note that predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope of our dispatch and therefore may incure additional days lead time to your order.

Orders requiring calibration. Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received late afternoon and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration. Be assured they will ship on the next dispatch, this in most cases should not add more than 24 hours to you delivery.

Delivery Surcharges
Because of the high cost of carriage we need to apply a surcharge on all deliveries made in the following regions bringing the carriage charges to:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands. 
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands.
  • Zone E - Northern Ireland
  • Zone F - Republic of Ireland

New Postage Map Sept 2018> 

International delivery

International delivery charges are automatically added to your order at the checkout; you can also use the guide below for a guide on prices. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

If no shipping option is available to your selected country please call us on +44 (0) 1603 406 148 to purchase your items.