TPI 770 Carbon Monoxide Monitor
- Audio/Visual indication
- Hand-held
- Multiple gas detection
- Instant response
- Audio/Visual indication
- Hand-held
- Multiple Gas Detection
-
-
Information on the calibration of newly purchased equipment and what it means to you.
Calibration and its certification comes in varying forms on new equipment and in this section, we will break it down into the three areas that we use to classify calibration state at the point of purchase.
Manufacturers Calibration Certificate
This is a calibration certificate offered by the manufacturer supplied with the tester. This is also known as an end-of-line certificate or manufacturer’s certificate. These certificates vary depending on the manufacturer and product. They will not have your company's name on them and don’t always show proven test results.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
This instrument comes complete with the manufacturer's calibration certificate. Please be aware that these certificates are generic and may also be time-lapsed.
If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.Manufacturers Certificate of Conformity
A manufacturer's certificate of conformity is not a calibration certificate. It is merely a statement that the equipment has been produced to operate within its intended application, it has no traceable certificate or constitutes any defined results for accuracy before leaving the manufacturing process.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.Personalised traceable calibration certificate from isswww
This is a calibration certificate created by us at ISS. This certificate is fully traceable to national and international standards. The certificate will show your company's details, tester information, proven test results and the equipment used to carry out the test. Nearly 90% of all calibrations we do are done in-house in one of our many fully equipped laboratories. You can add this service to your order on the product page before you checkout.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
We are on occasion able to offer FREE calibration on certain products at their point of sale (newly purchased equipment only) please look out for the following badge on the product's page to take advantage of this free offer.
-
-
TPI 770 Carbon Monoxide Monitor
The 770 CO Single Gas Monitor is a state-of- the-art Carbon Monoxide Instrument designed to measure Carbon Monoxide in ambient air and to perform a carbon monoxide build up test . It has a measurement range of 0 to 999 ppm (parts per million) and displays the readings in 1ppm increments.
The unit features a personal audible and visual alarm, which is factory set at 30ppm CO but can be changed in the field to keep current with government legislation.
The detector uses an advanced electrochemical sensor that measures Carbon Monoxide and should not be used for any other purpose.
*Important Calibration Information:
Please note that due to additional stringent procedures required to calibrate natural gas equipment, calibration on this instrument may unfortunately incur a longer turnaround.
Whilst we are acutely aware that this is not always convenient, we kindly request that you allow approximately 5-7 additional working days for purchases including calibration.
We will endeavor to always improve upon this but feel it is important to let our customers know before the purchase is made.
Key Features:
- Maximum reading hold
- Elapsed time and manual zero
- The audible alarm may be switched on and off as required
- Battery changing is made easy by use of a simple slide off battery compartment cover
Don’t expose yourself to Carbon Monoxide
- 9ppm: The maximum allowable concentration for short term exposure in a living area according to ASHRAE
- 50ppm: The Federal OSHA standard for continuous exposure in any eight hour period.
- 200ppm*: Maximum concentration allowable any time according to OSHA. Slight headaches, fatigue, dizziness, nausea after 2-3 hours.
- 400ppm*: Frontal headaches within 1-2 hours, life threatening after 3 hours. Maximum allowable limit in flue gas according to EPA and AGA.
- 800ppm*: Headache, dizziness, nausea, and convulsions with 45 minutes. Unconsciousness within 2 hours. Death within 2-3 minutes.
- 1600ppm*: Headache, dizziness, and nausea within 20 minutes. Death within 1 hour.
- 3200ppm*: Headache, dizziness, and nausea within 5-10 minutes. Death within 30 minutes.
- 6400ppm*: Headache, dizziness, and nausea within 1-2 minutes. Death within 10-15 minutes.
- 12800ppm*: Death within 1-3 minutes.
About TPI Europe
Since 1997, TPI has been striving to offer the latest technology at the most affordable price to technicians, contractors, engineers and others seeking value based test and measurement instruments. Our mission is to become the leading independent manufacturer and supplier of low cost high performance industrial instrumentation.
Headquartered in the heart of the “Silicon Forest” in Beaverton, Oregon, TPI combines innovation, performance, customer service and high-value in products which include: Vibration, Combustion, Pressure (manometers), Temperature, Combustible gas, Digital Multimeters, Clamp Meters, IAQ, specialty test and measurement instruments, and a wide range of accessories.
Key Features | Audio/Visual indication, Hand-held, Multiple gas detection, Instant response | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | |||||||||||||||||||||||||||||||||
Manufacturer | TPI Test Products International | |||||||||||||||||||||||||||||||||
Short Description |
|
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA