Martindale VI13800/2 Non Fused Voltage Indicator
- GS38 Compliant
- Current Test
- LED Indicator
- Indication of Polarity
- Tests Up To 600v
- Non-Fused
- Continuity Measurement
- Current Test
- GS38 Compliant
- Indication of Polarity
- LED Indication
- Non-Fused
- Tests up to 600v
-
-
Information on the calibration of newly purchased equipment and what it means to you.
Calibration and its certification comes in varying forms on new equipment and in this section, we will break it down into the three areas that we use to classify calibration state at the point of purchase.
Manufacturers Calibration Certificate
This is a calibration certificate offered by the manufacturer supplied with the tester. This is also known as an end-of-line certificate or manufacturer’s certificate. These certificates vary depending on the manufacturer and product. They will not have your company's name on them and don’t always show proven test results.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
This instrument comes complete with the manufacturer's calibration certificate. Please be aware that these certificates are generic and may also be time-lapsed.
If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.Manufacturers Certificate of Conformity
A manufacturer's certificate of conformity is not a calibration certificate. It is merely a statement that the equipment has been produced to operate within its intended application, it has no traceable certificate or constitutes any defined results for accuracy before leaving the manufacturing process.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.Personalised traceable calibration certificate from isswww
This is a calibration certificate created by us at ISS. This certificate is fully traceable to national and international standards. The certificate will show your company's details, tester information, proven test results and the equipment used to carry out the test. Nearly 90% of all calibrations we do are done in-house in one of our many fully equipped laboratories. You can add this service to your order on the product page before you checkout.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
We are on occasion able to offer FREE calibration on certain products at their point of sale (newly purchased equipment only) please look out for the following badge on the product's page to take advantage of this free offer.
-
-
Martindale VI13800 Non Fused Voltage Indicator
The new VI13800 is identical to the industry standard VI13700 except that it doesn’t have a fuse. This is so that it will comply with BS EN61243-3 2010 which came into force in May 2013. This standard bans the use of fuses in 2 pole voltage indicators.
Key Features:
- Industry standard voltage indicator
- Same as VI13700 but with no fuse
- Fully GS38 compliant
- Heavy duty double insulated leads
- Bright LEDs
- Polarity Indication
The VI13800 shows all the key safety characteristics of the older VI-13700/2. It has retractable prods, cable with an inner cover of a different colour to quickly identify damage cables and impedances at both ends to limit current flow if a lead should be broken, eg. by being sheared in a steel cabinet.
The standard relating to 2 pole voltage indicators is BS EN61243-3. All voltage indicators on the British & European market should comply. The latest version of the standard is BS EN61243-3:2010 and came fully in to force in May 2013.
The Martindale VI-13700 has been widely used for many years and as part of its design has always included a fuse in the probe to limit the current in the event of damage to the cable.
There is a technical argument that fuses in a voltage indicator can cause unreliability and any problem with the fuse could cause the voltage indicator not to indicate a hazardous voltage. In reality this risk is very small and correct proving procedures will identify the problem. None the less, because of this potential problem, BS EN61243-3 prohibits the use of fuses in 2 pole voltage indicators.
In order to fully comply with BS EN61243-3:2010 Martindale has released an updated version of VI-13700/2 with a model number of VI-13800. This new model has the fuse replaced by a high wattage resistor in the probe that will limit the current in the event of damage to the cable. This protection is superior to the protection offered by the fuse as the current that can flow under fault conditions is considerably less. The vast majority of competitor products have no protection built into the probe.
HSE Guidance note GS38 has not been revised for many years and therefore hasn’t kept pace with technology or international standards. It is due to be updated. The existing version of GS38 does not require fuses in a 2 pole voltage indicator built to a recognised standard such as BS EN61243-3.
Apart from the fuse/resistor in the probe everything else about the specification of VI-13700/2 & VI-13800 is identical, including the contrasting inner cable sheath to quickly identify cable damage.
In order to distinguish VI-13700/2 from VI-13800 the new model has the probe changed to all black instead of yellow. The probe is clearly marked “impedance protected” rather than showing a fuse rating. It is sealed and has no user replaceable parts.
There is no specific requirement to replace the VI13700 products which are in use. NB Proper proving procedures should always be used with any voltage indicator.
Key Features | GS38 Compliant, Current Test, LED Indicator, Indication of Polarity, Tests Up To 600v, Non-Fused | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Martindale | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
Updated January 2024
Please note, our cut-off time is 2:00pmOrders requiring calibrationWhilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery. Bank/Public HolidaysPredicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order. *UK Mainland (Revised March 2021)
Delivery SurchargesBecause of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
Offshore ServicesAll offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles. International deliveryInternational delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk ExportAll export inquiries should be directed to the export division before placement of order. If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
|