Martindale PSI4300 Non Contact Utility Phase Sequence Indicator
- Non-Contact
- Range 150-1000V 3 Phase AC
- LED Indication
- 15mA Battery Current Consumption
- Case Included
-
-
Information on the calibration of newly purchased equipment and what it means to you.
Calibration and its certification comes in varying forms on new equipment and in this section, we will break it down into the three areas that we use to classify calibration state at the point of purchase.
Manufacturers Calibration Certificate
This is a calibration certificate offered by the manufacturer supplied with the tester. This is also known as an end-of-line certificate or manufacturer’s certificate. These certificates vary depending on the manufacturer and product. They will not have your company's name on them and don’t always show proven test results.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
This instrument comes complete with the manufacturer's calibration certificate. Please be aware that these certificates are generic and may also be time-lapsed.
If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.Manufacturers Certificate of Conformity
A manufacturer's certificate of conformity is not a calibration certificate. It is merely a statement that the equipment has been produced to operate within its intended application, it has no traceable certificate or constitutes any defined results for accuracy before leaving the manufacturing process.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.Personalised traceable calibration certificate from isswww
This is a calibration certificate created by us at ISS. This certificate is fully traceable to national and international standards. The certificate will show your company's details, tester information, proven test results and the equipment used to carry out the test. Nearly 90% of all calibrations we do are done in-house in one of our many fully equipped laboratories. You can add this service to your order on the product page before you checkout.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
We are on occasion able to offer FREE calibration on certain products at their point of sale (newly purchased equipment only) please look out for the following badge on the product's page to take advantage of this free offer.
-
-
Martindale PSI4300 Non Contact Utility Phase Sequence Indicator
The Martindale PSI4300 is a unique phase rotation indicator that carries out the measurement via inductive crocodile clips. This method increases the safety of the user, whilst the bright green LEDs give a clear primary indication of anti-clockwise phase rotation.
The design of this phase rotation tester allows for use on both insulated or uninsulated conductors, and an "Enhanced Brightness" switch makes indication brighter in strong ambient light. A combination of both rotating LEDs and buzzer tones indicate clockwise or anti-clockwise rotation.
The Martindale PSI4300 Is Supplied With:
- 4 x AA Batteries
- Soft Carry Case
- Instruction Manual
Key Features:
- Measurement Principle - Static Induction
- Input Voltage - 150V - 1000V 3 Phase AC
- Frequency Range - 45 - 65Hz
- Operating Temperature & Humidity -10ºC to 50ºC, Max 80%
- Battery Current Consumption - 15mA
- Cable Length - Approx. 800mm
- Power Source - 1.5V x 4 AA / LR6 alkaline batteries
- Low Battery Warning - Power LED Flashes Below 4.6V DC Battery Voltage
- Safety Standard - EN 61010 CAT III 1000V, CAT IV 600V, EN 61326-1~
ISSWWW and Martindale Electric
Founded in 1928 and also owns Edgcumbe Instruments Metrohm® products, as well as the John
Drummond Engineers range of test lamps. They are a British owned company, based in Watford, just 5 minutes from junction 5 of the M1. Their product range helps electricians and maintenance engineers carry out portable appliance testing, check fixed wiring for 17th Edition and Part P testing, safely prove dead, and measure everything from light and sound levels to microwave leakage and power consumption.
We are proud to be able to offer Martindale's products and services and have done so for many years.
Key Features | Non-Contact, Range 150-1000V 3 Phase AC, LED Indication, 15mA Battery Current Consumption, Case Included | ||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||||||||||||||||||
Manufacturer | Martindale | ||||||||||||||||||||||||||||||||||||||||
Short Description | Martindale PSI4300 Non Contact Utility Phase Sequence Indicator
|
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA