Like most organisations we use cookies on our site, these allow us to improve your experience on our site, provides us with measurement and analytical data, and allows us to make use of the latest digital marketing capabilities - if you want to know more about cookies and how you can control them see our cookie policy here, if you are happy for us to use cookies then please click the button opposite.
The images provided are for illustrative purposes only. Please refer to product description.

Fluke 568 Ex Infrared Thermometer

The Fluke 568 Ex Intrinsically Safe Infrared Thermometer.

Next Day Delivery (subject to availability)

£1,019.00 exc. VAT £1,222.80 inc. VAT £1,462.80 inc. VAT
  • Includes Software
  • Measures -40 °C to 800 °C
  • Type K input
  • Probe included
  • Data transfer via USB
  • Emissivity adjustment
  • Intrinsically Safe
  • FreeDelivery
  • 30DayMoneyBack
Required Fields
  • Description
  • Features & Specification
  • Resources
  • Delivery

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in hazardous environments anywhere in the world

 

The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.

 

Fluke 568 Ex Comes Supplied With:

  • K-type thermocouple bead probe
  • Conductive IS hard carrying case
  • User’s manual

With a straight-forward user interface and soft-key menus, the Fluke 568 Ex makes even complex measurements easy. Quickly navigate and adjust emissivity, save data or turn on and off alarms, with just a few pushes of a button. All in a single intrinsically safe tool certified by major rating bodies from around the world.

 

With a rugged, easy-to-use, ergonomic design, the Fluke 568 can stand up to tough industrial, electrical, and mechanical environments.

  • Meets intrinsically safe certifications in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments from recognized safety agencies around the world
  • Measure -40 °C to 800 °C /-40 °F to 1472 °F
  • Conductive Case for carrying the IR thermometer safely into hazardous area
  • Easily access advanced features with the soft-key buttons and graphical display
  • Measure small objects from further away, with a distance-to-spot ratio of 50:1
  • Compatible with mini-connector K-type thermocouple (KTC) probe
  • Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table
  • Capture up to 99 points of data
  • Confidently troubleshoot equipment with ± 1 % measurement accuracy
  • Versatile interface with five languages from which to choose
  • Two-year warranty

About Intrinsically Safe Products

Products that appear on this website that are listed as or relate to a classification of intrinsic safety are titled and described according to our best understanding and/or interpretation of the complex and sometimes changing criteria governing such classification as set out by the Health and Safety Executive.

Please note that due to the volatile nature of the intended use of products in this category,  neither UK Test Instruments or Instrument Sales and Service can be held responsible for any incident that arises from the purchase or use of any product described within this web site. For more information please visit the health and Safety Executive website with specific regard to Hazardous Area Classification and Control of Ignition Sources.

 

Infrared temperature range -40°C to 800°C (-40°F to 1472°F)
Infrared accuracy < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple type-k input temperature range -270°C to 1372°C (-454°F to 2501°F)
Thermocouple type-k input accuracy < -40°C: ±(1°C + 0.2°/1°C)
≥ -40°C: ±1% or 1°C, whichever is greater < -40°F: ±(2°F + 0.2°/1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
D:S (distance to measurement spot size) 50:1
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable celsius and fahrenheit Yes
Power 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
Battery life 4 hours with laser and backlight on; 
100 hours with laser and backlight off, at 100% duty cycle
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-40°F to 140°F)
Bead thermocouple type-k range -40°C to 260°C (-40°F to 500°F)
Bead thermocouple type-k accuracy ±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F), 
typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring
calibration may on occasion miss dispatch that day, according to the complexity of the calibration. Be assured they will ship on the next dispatch
this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope 
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.


*UK Mainland (Temporarily revised June 2020)

Please note that regrettably, we have had to realign our delivery service options to those available from our carriers.
During the current situation surrounding the effects of the Coronavirus pandemic, logistics from every company are under immense pressure to deliver goods on time.
We have taken the decision to temporarily limit our services rather than let our customers down.
We hope you will understand our position on this and we apologise unreservedly for the inconvenience we know this will cause.
We look forward to restoring our full delivery service schedule just as soon as we are able.

Standard FREE 1-2 Day Courier Delivery – UK Mainland only - Zones A & B

Included in the price for all orders over £75.00 (exc vat). Sent using express courier, delivered within 1-2 working days from the date of your order, subject to availability.

 

Next Day Anytime Delivery (Excluding Saturday & Sunday) – UK Mainland only - Zones A & B
Sent by express courier, delivered next day (excluding weekends) from the date of your order, subject to availability.

 

Orders must be placed before 3:00pm for a qualifying next day delivery and a telephone number supplied, subject to availability.

New Postage Map Sept 2018>

Delivery Surcharges

Because of the high cost of carriage, we need to apply a surcharge on all deliveries made in the following regions bringing the carriage charges to:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 2 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International Delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk