Chauvin Arnoux CA895 Carbon Monoxide Detector P01651001Z
- Accuracy ± 5 ppm
- Backlit 2000-ct display
- Calibration Function
- Dual Mode Operation
- Range 0-1000 ppm
- Audible & Visual Indication
-
-
Information on the calibration of newly purchased equipment and what it means to you.
Calibration and its certification comes in varying forms on new equipment and in this section, we will break it down into the three areas that we use to classify calibration state at the point of purchase.
Manufacturers Calibration Certificate
This is a calibration certificate offered by the manufacturer supplied with the tester. This is also known as an end-of-line certificate or manufacturer’s certificate. These certificates vary depending on the manufacturer and product. They will not have your company's name on them and don’t always show proven test results.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
This instrument comes complete with the manufacturer's calibration certificate. Please be aware that these certificates are generic and may also be time-lapsed.
If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.Manufacturers Certificate of Conformity
A manufacturer's certificate of conformity is not a calibration certificate. It is merely a statement that the equipment has been produced to operate within its intended application, it has no traceable certificate or constitutes any defined results for accuracy before leaving the manufacturing process.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.Personalised traceable calibration certificate from isswww
This is a calibration certificate created by us at ISS. This certificate is fully traceable to national and international standards. The certificate will show your company's details, tester information, proven test results and the equipment used to carry out the test. Nearly 90% of all calibrations we do are done in-house in one of our many fully equipped laboratories. You can add this service to your order on the product page before you checkout.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
We are on occasion able to offer FREE calibration on certain products at their point of sale (newly purchased equipment only) please look out for the following badge on the product's page to take advantage of this free offer.
-
-
Chauvin Arnoux CA895 Carbon Monoxide Detector
In a compact casing protected by a shockproof sheath, the Physics Line C.A 895 CO-gas detector detects and measures carbon monoxide.
It has 2 measurement modes “normal” for the detection of a source of CO and “average” for precise measurement.
It incorporates an audible beeping sound upon detection, a similar principle to that found on a Geiger counter.
*Important Calibration Information:
Please note that due to additional stringent procedures required to calibrate natural gas equipment, calibration on this instrument may unfortunately incur a longer turnaround.
Whilst we are acutely aware that this is not always convenient, we kindly request that you allow approximately 5-7 additional working days for purchases including calibration.
We will endeavor to always improve upon this but feel it is important to let our customers know before the purchase is made.
Key Features:
- Hold and Maximum Functions
- Backlit 2000-ct display
- Protective shock-proof sheath
A closer look at Carbon Monoxide (CO).
- Carbon monoxide is a colorless, odorless, tasteless, and toxic gas produced by the incomplete combustion of carbonaceous materials: coal, paper, gasoline, diesel oil, gas, wood, etc.
- Lighter than air, it rapidly diffuses in the atmosphere leaving no way to detect it, which gives it its dangerous character.
Many sources of carbon monoxide can be found in the home:
Gas stoves
Fuel-fired furnaces and gas water heaters, chimneys;
Cigarette smoking: each smoked cigarette emits 50 mg of CO
To avoid dangerous levels of CO, it is important to maintain all combustion appliances in good working order: charcoal heaters, gas heaters, wood stoves, water heaters, gas stoves, and open chimneys; schedule chimney-sweeping and flare conduit cleaning at least once a year. One must ensure that there is adequate ventilation in rooms containing combustion installations (kitchen, garage, bathroom) and especially avoid blocking or crushing ventilation apertures.
CO concentration / human danger scale
De 0 to 1 ppm | normal level of CO in the air |
9 ppm | maximum level in a room with no harm to health |
50 ppm | maximum level bearable for continuous exposure during 8 hours |
200 ppm | mild headache, nausea, dizziness |
400 ppm | serious headache, life threatening after 3 hours |
800 ppm | death after 2 hours |
1,600 ppm | nausea in 20 minutes, death after 1 hour |
12,800 ppm | death within 1 to 3 minutes |
isswww and Chauvin Arnoux
The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with the design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond.
ISSWWW and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over.
De 0 to 1 ppm
Key Features | Accuracy ± 5 ppm, Backlit 2000-ct display, Calibration Function, Dual Mode Operation, Range 0-1000 ppm, Audible & Visual Indication | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||
Manufacturer | Chauvin Arnoux | ||||||||||||||
Short Description |
|
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA