Chauvin Arnoux CA6550 10KV Insulation Tester P01139715
- Case Included
- Multiple Test Modes
- PC Report Generation
- Range 10 kΩ to 30 TΩ
- Storage of 80
- 000 measurements
- Test Voltages 40 V to 10/15 kV
- Windows® software included
-
-
Information on the calibration of newly purchased equipment and what it means to you.
Calibration and its certification comes in varying forms on new equipment and in this section, we will break it down into the three areas that we use to classify calibration state at the point of purchase.
Manufacturers Calibration Certificate
This is a calibration certificate offered by the manufacturer supplied with the tester. This is also known as an end-of-line certificate or manufacturer’s certificate. These certificates vary depending on the manufacturer and product. They will not have your company's name on them and don’t always show proven test results.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
This instrument comes complete with the manufacturer's calibration certificate. Please be aware that these certificates are generic and may also be time-lapsed.
If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.Manufacturers Certificate of Conformity
A manufacturer's certificate of conformity is not a calibration certificate. It is merely a statement that the equipment has been produced to operate within its intended application, it has no traceable certificate or constitutes any defined results for accuracy before leaving the manufacturing process.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.Personalised traceable calibration certificate from isswww
This is a calibration certificate created by us at ISS. This certificate is fully traceable to national and international standards. The certificate will show your company's details, tester information, proven test results and the equipment used to carry out the test. Nearly 90% of all calibrations we do are done in-house in one of our many fully equipped laboratories. You can add this service to your order on the product page before you checkout.
Where applicable we will include the following statement relating to the item/s on the products page under the heading *Important Calibration Information.
We are on occasion able to offer FREE calibration on certain products at their point of sale (newly purchased equipment only) please look out for the following badge on the product's page to take advantage of this free offer.
-
-
Chauvin Arnoux CA6550 10KV/15kV High Voltage Insulation Tester
Insulation Measurement at 15kV, a job for experts
With their test voltages of up to 10 kV/15 kV, the CA6550 and CA6555 megohmmeters are expert tools for testing insulation safely and accurately. As they comply with the most recent recommended practice while taking into account future developments, they are ideal for use on rotating equipment and machinery operating at 12 kV or even higher.
The multiple test modes mean that you can both assess the insulation in qualitative terms by non-destructive testing (“I-limit” and “early-break” modes) and use samples to investigate insulation ageing problems for preventive maintenance purposes (“burning” mode). The C.A 6550 and CA6555 offer quick, effective checking of test execution by displaying the evolution of the test in progress in graphic form.
Thanks to their large storage capacity, complete analysis of the test sessions performed on-site can be carried out with the DataView® software after transferring the data onto a PC.
Chauvin Arnoux CA6550 Comes Supplied With:
- CAT IV Accessory Bag
- 2x 3m Safety Leads
- 1 Guard Test Lead
- Mains Power Cord
- 3x Crocodile Clips
- USB/Optical Communication Cable
- User Guide
- DataView Software
Key Features:
- Wide measurement range from 10 kΩ to 30 TΩ
- Fixed or programmable test voltage from 40 V to 10/15 kV
- 5 mA charging current
- Large backlit LCD screen with digital display, bar graph and R(t)+u(t) , i(t) and i(u) graphs
- Automatic calculation of DAR / PI / DD /∆R (ppm/V) ratios
- Multiple test modes: voltage ramp and step with “burning”, “early break” and “I-limit” modes
- 3 filters to optimize measurement stability
- Calculation of R at a reference temperature
- Storage of 80,000 measurements and Real-time Clock
- Optically-isolated USB communication for transfer onto PC and report generation with the DataView® software
Key Applications:
Thanks to their large measurement range, extending up to 30 TΩ, the CA6550 and CA6555 meet the requirements of companies manufacturing cables, transformers, rotating machinery, and medium-voltage generators, as well as professionals in the Electricity Transmission and Distribution sector.
Insulation measurement at up to 10/15 kV
On LV/HV rotating machines, transformers, cables, high-voltage generators, overhead and underground electricity transmission and distribution networks, surge suppressors/spark arresters, measurement transducers, etc.
2 levels of diagnostics :
- “Go/No Go” test
- Qualitative measurement for preventive maintenance purposes:
- Test with programmable duration
Qualitative measurement:
Polarization Index (PI) ratio, dielectric absorption ratio (DAR) and dielectric discharge (DD) index for testing heterogeneous multi-layered insulation
Fixed voltage mode
Step, Ramp mode:
- Results independent of temperature, detection of insulant cracking and ageing
I-limit or dI/dt (early-break) trigger modes:
- Optimization of non-destructive tests (e.g. Varistor testing)
Burning mode (no triggering)
Selectable voltage from 40 V to 10,000 / 15,300 V
Graphic LCD display of R(t) + u(t), I(t), I(u) (useful for testing semi-conductors)
Storage of results for export onto a PC
- Using analysis software to process the measurement logs.
isswww and Chauvin Arnoux
The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with the design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond.
ISSWWW and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over.
Key Features | Case Included, Multiple Test Modes, PC Report Generation, Range 10 kΩ to 30 TΩ, Storage of 80,000 measurements, Test Voltages 40 V to 10/15 kV, Windows® software included | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Chauvin Arnoux | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
|
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA