Chauvin Arnoux B102 Earth Leakage Clamp P01120083
- 112mm Maximum Conductor Size
- Jaw Opening 110mm
- Maximum 400A AC
-
-
-
We are confident that our prices are among the lowest you will find.
If you manage to find a lower price online please call us on 08000 224 060 or fill out the details below and we'll get back to you via email or phone.
Please note - We do not accept Price Match submissions against bidding and auction sites like Amazon and eBay.
This service is only available to .co.uk sites.
Chauvin Arnoux B102 Earth Leakage Clamp
The B102 clamp is designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currents on power circuits.
Key Features:
- differential or leakage current, from 500 µA
- currents up to 400 A max
- 2 measurement ranges: 1 mV/mA or 1 mV/A
- used on single or multi-phase systems, with phased or unphased currents, and on balanced or unbalanced circuits
- 110 mm jaw opening
- measurement of fault currents on 3-wire 3-phase circuits without a neutral using an artificial neural system
The only model in the B series, the B102 is designed to measure earth leakage currents caused by insulation faults.
It enables the fault to be located and diagnosed before failure occurs thus avoiding installation shutdown. It is designed specifically for locating low-current faults on
high-current circuits.
The B102 measures differential or leakage current from 500 μA upwards and may be used to measure currents up to 400 A in continuous use (400 A max.). The B102 has two measurement ranges, 1 mV/mA or 1 mV/A. As a leakage current detector, the B102 can be used on single or multiphase systems whether the currents are in or out of phase, balanced or unbalanced.
The B02 may be used simply as a high-precision clamp-on current probe. With its 115 mm jaw opening and dynamic measurement range from 500 μA to 400 A, the B102 is a versatile instrument, highly useful in the analysis of unbalanced circuits, leakage currents, and earth loop currents. When operated in conjunction with an artificial neutral, the B102 can also be used to measure fault currents on 3-phase circuits with no neutral.
isswww and Chauvin Arnoux
The Chauvin Arnoux Group of companies, incorporating the Metrix and Multimetrix brands are synonymous with the design and production of the finest quality products for the electrical testing industry, covering a diverse sector of the market for over 100 years. From their awarded Digiflex current sensors, universal testers, multimeters, network and power analysers, right up to laboratory instrumentation and beyond.
ISSWWW and Chauvin Arnoux have enjoyed a close working partnership for many years and we supply many of their products to trade and industry the world over.
Key Features | 112mm Maximum Conductor Size, Jaw Opening 110mm, Maximum 400A AC | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||||||||||||||
Manufacturer | Chauvin Arnoux | ||||||||||||||||||||||||||||||||||||
Short Description |
|
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA