Chauvin Arnoux Power Logger PEL113-C (with clamps and adapter) P01300003

Product Code: CHAPEL113-C

Price
£2079.00 ex. VAT £2494.80 inc. VAT

Available In 3-7 Days


Add To Favourites
Detailed Description

PEL113 STAND-ALONE UNIT

This listing is for the PEL113 power & energy logger WITH phase clamps and power adapter. Please see our listing here for the basic package without these included items.

Save money by controlling your energy consumption. To optimize your energy efficiency, reduce costs and improve the performance of your electrical systems, the simultaneous power and energy loggers in the PEL 110 Series are ideal tools.

Key Features:

  • Possibility of recordings covering several months
  • Breakdown of energy losses
  • Installation without cutting off the mains supply
  • Android application with motor diagnostics

From electricity generators through to consumers, the PEL power loggers are very simple to interface everywhere.

  • Renewable energies photovoltaic, wind, hydroelectric, thermal and thermo-dynamic
  • Process industries metallurgy, glassmaking, paper, chemicals, agri-food, etc.
  • Building construction and renovation housing, facilities, etc.
  • Public services/transport monitoring where the consumption is occurring (lighting, roads, motorways, tunnels, rail, etc.)
  • Datacenter monitoring and analysis of consumption

Comes Supplied With:

  • 1 carrying bag
  • 3x MA194-350 MiniFlex Sensors
  • Power adapter
  • 4 voltage cables
  • 4 crocodile clips
  • 1 set of inserts/ rings
  • 1 SD card
  • 1 SD Card-USB adapter
  • 1 USB cable
  • PEL TRANSFER PC software & User’s Manual downloadable from our website
  • 1 Quick Start Guide

ENERGY AUDITS 

  • Voluntary (ISO 50001, etc.) or mandatory operation aiming to reduce energy consumption: buildings, housing, infrastructure, equipment, etc.
  • Implementation of measurement campaigns focused on energy for comprehensive diagnosis of the electrical installation
  • Identification of the causes of overconsumption by the equipment or overbilling

PREVENTIVE AND PREDICTIVE MAINTENANCE

  • Industrial equipment monitoring 
  • Analysis of consumption due to the Air-conditioning, Ventilation and Heating systems
  • Sizing of a power factor correction cabinet
  • Redistribution of the loads on the electrical grid
  • + Motor diagnostics: measurement of a motor’s speeds, efficiency and torque without using mechanical sensors

Measurements and Functions:

VOLTAGE

  • RMS and DC measurements with 128 samples/cycle simultaneously on each phase
  • AC and/or DC voltage measurements up to 1,000 V
  • Current up to 10 kA AC, 5 kA DC (depending on the current sensor).
  • Active, reactive (N,D,Qf) and apparent power values
  • Active energy values
  • Fundamental active power values (Pf), balanced active power values (P+) and unbalance active power (Punb)
  • Motor measurements and characterisation

POWER/POWER FACTOR

  • Self-powered via the phase
  • Extensive measurement range by using voltage and current ratios
  • Breakdown of energy losses
  • The phase data: cos φ, tan Φ, power factor (PF)
  • Crest factor z THD calculation for currents and voltages
  • DC, 50 Hz, 60 Hz and 400 Hz measurements (Naval, etc.)
  • Recording of the measurements and calculation results on the SD card 
  • Automatic recognition of the type of sensor connected

PEL Transfer software

This application software can be used to set up the PEL 110s and process the energies. A mathematical algorithm applied to the power measurement campaigns automatically provides a breakdown of all the energy values, highlighting any losses detected. Users have everything they need to rank the priorities of their operations. Energy consumption reports can be generated very simply.

With PEL Transfer, you obtain the value of your electricity consumption in the local currency (€, £, $, etc. - 8 tariff ranges).

  • Flexible current sensor
  • IEC 61010 1000V CAT III et 600V CAT IV

MiniFlex® MA194 250 mm Current Clamps


Current clamps, MiniFlex® and AmpFlex® flexible current sensors are used to measure the current flowing in a cable without opening the circuit. They also insulate the user from dangerous voltages in the circuit.Measurement range 100 mA - 10 000 A 
Clamping diameter 70 mm
Dimensions (L x l x H) environ 130 x 80 x 18 mm
Cord 3 metres long
Weight approx. 110 g

MiniFlex® MA194 350 mm
Measurement range  100 mA - 10 000 A 
Clamping diameter 100 mm
Dimensions (L x W x H) approx. 170 x 110 x 18 mm
Cord 3 metres long
Weight approx. 120 g

Network Communication:

The PELs are equipped with a wide range of wired and wireless communication possibilities. The free PEL Transfer software interface allows you to monitor the data on a PC in real time.

Ethernet

When possible, the PELs can be connected together via an Ethernet-type wired link. The PEL Transfer software then takes control of all the instruments connected. The Ethernet link can be used at the same time as Wifi connections.

WiFi

The PELs offer 2 Wifi operating modes. They can be connected to the company’s IT network via a server. They can also be addressed directly by a PC or smartphone.

IRD DataView® Synch

A secure server is provided so that you can view your data from anywhere in the world.

USB

USB connections can be used to configure or download the data, as well as to take control of an instrument whatever the circumstances.

Choose your model:

Standard Version Kit Version
Chauvin Arnoux PEL113 Portable & Energy Logger 

4x Voltage Cables

4x Crocodile Clips

1x Set of Inserts/Rings

SD Card

SD Card-USB Adapter

USB Cable

PEL Transfer Software

Quick Start Guide

MA194-350 MiniFlex Sensors & Adapter

Technical Specification:

PEL112 PEL113 PEL115
Display None Quadruple digital display
Types of installations Single-phase, split-phase, three-phase with or without neutral, and many other specific configurations
Number of channels 3 voltage inputs, 3 current inputs (neutral current calculated) 4 voltage inputs, 4 current inputs
Measurements
Network frequencies DC, 50 Hz, 60 Hz and 400 Hz
Voltage (measurement ranges) 10.00 - 1,000 Vac / 100.00 – 1,000 Vdc
Current (see previous page) 5 mAac to 10 kAac / 50 mAdc to 5 kAdc
Calculated measurements
Ratio Up to 650,000 V / up to 25,000 A
Power (P, Pf, P+
, Punb, Qf, N, D, S)
10 W to 10 GW / 10 var to 10 Gvar / 10 VA to 10 GVA
Energy Up to 4 EWh / 4 EVAh / 4 Evarh (E = 1018)
Phase cos φ, tan Φ, PF
Harmonics THD
Additional functions
Phase order Yes
Min / Max Yes
Alarm Yes
Mounting Magnet Hook (Opt.)
Recording 
Acquisition rate / Aggregation period 5 measurements/s - 1 min to 60 min
Data storage SD card, 8 GB (up to 32 GB on SD-HC card)
Communication USB, Ethernet, Wifi (Access point and Hotspot), IRD Server DataView® Synch
Power supply 110 V - 250 V (+10 %, -15 %) at 50-60 Hz & 400 Hz Powered by the phase – 1,000 V AC/DC
Safety IEC 61010 600 V CAT IV and 1000 V CAT III IEC 61010 1000 V CAT IV
Mechanical Specifications 
Dimensions 256 x 125 x 37 mm without sensor 245 x 270 x 180 mm without sensor
Weight 900 g 950 g <3400 g
Casing IP54 IP67
Operating temperatures -20 °C to +50 °C 0 °C to +50 °C -20°C to +50 °C