Kewtech SMARTPAT PAT Tester

Product Code: KEWSMARTPAT

Price
£595.00 ex. VAT £714.00 inc. VAT

In Stock


Add To Favourites
Detailed Description

The SMARTPAT Wi-Fi controlled PAT tester stands out as the fastest PAT solution available.

This innovative tester is the world’s first Wi-Fi-enabled PAT tester, allowing for remote control via the free KEWPAT App on your smartphone or tablet. This feature streamlines the testing process, enabling users to conduct tests more efficiently and with greater ease.

In addition to its remote control capabilities, the SMARTPAT offers a comprehensive range of testing functions, ensuring that all necessary checks are performed swiftly and accurately. Its user-friendly interface and advanced features make it a top choice for professionals seeking to enhance their PAT testing procedures.

As well as covering all your basic requirements for Portable Appliance Testing, the SMARTPAT hosts a number of advanced features that mean you can be sure you have a PAT to test any appliance. The SMARTPAT has an added benefit of being able to conduct a run leakage test at 230V and 110V, a unique feature in the battery powered market to Kewtech. There is also an advanced function to perform 10mA and 30mA Portable RCD tests.

Key Features:

  • Performs Earth bond at 200mA (IT safe)
  • Battery operated - approx. 1400 tests
  • Converts into a full downloading PAT tester with the KEWPAT APP
  • Automatic test sequences - make your own with the KEWPAT APP
  • For fast data collection and results saving works in connection with the KEWPAT APP
  • PASS / FAIL – Green / Red screens
  • Appliance status pre-check
  • Quick check continuity
  • 5 second continuity
  • 250 V and 500 V insulation
  • Substitute leakage test
  • Selectable substitute leakage limits
  • Extension lead test
  • Test lead nulling
  • Back light
  • Extension lead adapter
  • Earth Continuity test lead with probe
    and croc clip
  • Carry bag with handle
  • Quick start guide

Kewtech SMARTPAT Comes Supplied With:

  • Extension lead adapter (EZYLEAD) 
  • Earth continuity test lead with probe and croc clip (EZYEARTH)
  • Mains Lead (EZYMAIN)
  • Carry bag with strap

Key Benefits:

  • Easy to use
  • Converts into a full downloading PAT Tester with the KEWPAT APP
  • Automatic test sequences - standard or make your own
  • Large clear display
  • Battery operated - approx. 1400 tests
  • IT safe with 200mA earth test 250V insulation option
  • PASS / FAIL – Green / Red screens
  • Run / leakage at supply voltage (110V or 230V)
  • Portable RCD tests 10mA & 30mA

Data Collection

Provides a very fast solution for logging your testing. Special drop down menus on the APP ensures quick appliance documentation enabling you to add basic information such as appliance and location, or more detailied logging such as make, model, serial number and special comments.

Testing

The APP controls the tester so you can use the standard auto-tests or make up your own. The test results are automatically included in the appliance record.

Risk Assessment

All appliances need a risk assessment. The APP has a risk assessment function that is designed to be optionally engaged during each test if required, leading to the desired frequency of re-test.

Cable Resistance

Class 1 equipment has a variable pass limit depending on the length of the mains lead. There is a simple cable calculator on the APP that can be easily engaged during testing.

Extra Functionality

The APP makes full use of your mobile device as it can take pictures, scan barcodes / QR codes and can also give you voice prompts.

The SMARTPAT in conjunction with the KEWPAT APP and the SimplyPats Manual+ software is the ultimate in PAT testing. It gives you control over your testing sequences, you can collect as much data as you need, including risk assessment, and provides an easy-to-use, yet sophisticated PC based product register. Modern technology making testing faster, easier and more robust

KEWPAT APP:

The SMARTPAT, together with the KEWPAT APP, covers all the functionality and more of a traditional downloading PAT tester.

The KEWPAT app, in conjunction with KEWTECH testers, changes the face of PAT testing by removing all the data logging leg work and allowing you to be more efficient with your testing. KEWPAT can be operated manually with any Kewtech PAT tester enabling fast manual documentation including appliance risk assessment, record documentation and covers your obligations for holding a product register.

The app has a large data storage for high volume testing to meet all your PAT testing needs. You can take a picture and add it to the product register, scan a barcode, and add your own logo to printed labels all in a matter of seconds. You can even produce a professional PDF report ready for email or print through the app. Alongside the SMARTPAT you can see the true power of the markets most efficient testing solution. By running the tester from the KEWPAT app you will have your results sent straight back to your app in a matter of seconds!

The KEWPAT app can also operate the KEW80L Bluetooth Printer which instantly prints your PASS/FAIL labels with a number of different designs to choose from, including barcodes and QR codes. Simply scan the QR or barcode label and the app will auto-populate with the appliance previously collected data for even faster testing on your return visits.

If you are looking for greater flexibility in managing your PAT testing data and want access to large number of PAT Test Reporting and Invoicing options, then SimplyPats Version 7 (Downloading Edition) can already import and export data to and from the KEWPAT App.

Key Benefits:

  • FREE to download on iOS and Android devices
  • Works with any tester for manual input of data
  • One-to-one Wi-Fi connection can be used to control the SMARTPAT
  • Works via Bluetooth to control KEW80L label printer
  • Data collection, Risk assessment, Cable calculator, Reporting, Record saving
  • Customisable Auto-tests

Key Features:

  • Turns your Kewtech SMARTPAT into a remotely operated downloading PAT Tester
  • Also a great option, in manual mode, for Kewtech EZYPAT or EZYPAT Plus users
  • Fast entry of the essential product information
  • Dropdown menus for customer, site, location and description
  • A tool to help you with appliance risk assessment and testing frequency
  • Save your records with any additional information
  • Add pictures to the product register
  • Scan barcodes/QR codes
  • Voice prompt help
  • Add your own logo to printed labels, if you wish using the KEW80L
  • Customer signature for sign off facility

Spares & Accessories:

ELII0PAT KIT 110v appliance adapter kit
ELKIT ELII0PAT kit plus 230v & 400v 16A adapters
EZYMAIN 110V 110v supply lead for the EZYPAT Plus and SMARTPAT
KEWSNAP 1 50 Snap tags with clips
KEWSNAP 2 50 Snap tags without clips for cable tie fixing
KEWPRINT Bluetooth label printer
KEWROLL 460 Labels for Kewprint
LR EARTH Long reach 65mm earth probe
PATLOG 1 A4 PAT testing log book / product register
PATLOG 3 A5 PAT testing log book / product register
250FAIL 250 appliance fail labels
500PASS 500 appliance pass labels
500VIS 500 appliance visual pass labels
KEWPAT APP Free Download from kewtechcorp.com

Protective Conductor Resistance Test
Measuring range  0.00 - 20.00 Ω (NULL value inc)*
Over-range indication > 20.00 Ω
Resolution 0.01Ω
Open-circuit voltage 5 V ±0.4 V DC
Measuring current 200 mA DC (nominal value)
Accuracy ±3%rdg ±5dgt
Mains Voltage
Display Range 30 - 270 V
Hi/Lo Indication < 30 V: No voltage indication; > 270 V: 270 V
Resolution & Accuracy 1 V & ±3%rdg ±5dgt
Insulation
Rated Voltage 250v 500v
Measuring Range 0.00 - 20.00 MΩ
Over-range Indication > 20.00 MΩ
Resolution 0.01 MΩ
No-load Voltage 250 V DC +20%, -0% 500 V DC +20%, -0%
Short-circuit Current 1.5 mA DC or less
Rated Current  1 -1.2 mA with a load of 0.25 MΩ 1 to 1.2 mA with a load of 0.5 MΩ
Accuracy ±2%rdg±3dgt
Sustitute Leakage
Measuring range 0.10 - 12.00 mA rms
Over-range indication > 12.00 mA
Resolution 0.01mA
Open-circuit voltage/ Freq 30 V ±5 V rms / 50 Hz ±5%
Measuring current 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
Accuracy ±3%rdg±5dgt
Insulation Test Between L & N
Open-circuit voltage 4.5 V ±0.5 V DC
Criteria of judgement 100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted.
Run Leakage (Item: Load current / Leakage current) EZYPAT Plus and SMARTPAT ONLY
Mains voltage range 100 - 253 V / 50 Hz
Measuring range 0.10 - 13.00 A rms 0.10 - 20.00 mA rms
Display range 0.00 - 13.00 A 0.00 - 20.00 mA
Over-range indication > 13.00 A > 20.00 mA
Resolution 0.01A / 0.01mA
Accuracy ±10%rdg ±5dgt / ±3%rdg ±5dvgt
Max. rating 3 kVA max., 15 sec. cont. / -
RCD Test SMARTPAT ONLY
Rated voltage 230 V - 15% to +10% / 50Hz
Rated current 10 mA / 30 mA
Test duration ×1: 0.0 ms - 500.0 ms / ×5: 0.0 ms - 40.0 ms
Test current accuracy 2% - 8%
Operating time accuracy ±2 ms ( 40 ms) ±8 ms (>40 ms)
UK Mainland Order by 2pm for Next Day Delivery*
Under £25.00 £4.50
Over £25.00 FREE

UK Highlands & Islands Order by 2pm for Next Day Delivery*
Under £80.00 £15.00
Over £80.00 FREE