Product Code: MEG1010-361
Available In 3-7 Days
The MTR105 is a dedicated rotating machine tester that brings Megger’s proven insulation resistance (IR) expertise together with advanced low resistance, capacitance, inductance, and rotation testing in one handheld instrument. It delivers a holistic view of motor health, enabling you to assess windings, connections, and overall condition with precision and confidence. Designed for production, service, and maintenance teams, the MTR105 supports fast, reliable decisions across your asset lifecycle.
Built on a unified test architecture, the MTR105 consolidates multiple core measurements:
This integrated approach reduces set‑up time, cuts the number of tools you carry, and streamlines workflows in the field or workshop.
Stable test voltages and four‑wire measurement techniques underpin consistent, repeatable readings. Temperature measurement and compensation keep IR results aligned to reference conditions, so trends are meaningful across seasons and sites. Clear, full‑colour graphics present values and trends at a glance, allowing you to validate pass/fail criteria and move decisively to the next task.
The MTR105 is designed to protect both operator and instrument. Fast live‑voltage detection inhibits tests if hazardous voltage is present, reducing the risk of damage when connected to energised circuits or across phases. User‑selectable test terminal lockout thresholds add another layer of control, while robust internal protection supports safe use in CAT III 600 V environments.
A tough, over‑moulded housing and IP54 environmental protection defend against dust, moisture, and daily knocks. Detachable, interchangeable leads adapt to different applications and maintain reliable connections. With onboard storage for up to 256 motors and simple USB download, you can capture, share, and analyse results as part of a connected maintenance ecosystem.
By unifying essential motor tests in a single instrument, the MTR105 helps you shorten diagnostics, standardise procedures, and improve asset reliability. Whether you are commissioning new equipment, verifying repairs, or conducting routine maintenance, the MTR105 provides the clarity, safety, and durability you need to work with confidence.
| Specifications - All quoted accuracies are at 20ºC (68ºF) | ||
| Insulation resistance | ||
| Volts | Accuracy | |
| 50 V | 10 GΩ ±2% ±2 digits ±4.0% per GΩ | |
| 100 V | 20 GΩ ±2% ±2 digits ±2.0% per GΩ | |
| 250 V | 50 GΩ ±2% ±2 digits ±0.8% per GΩ | |
| 500 V | 100 GΩ ±2% ±2 digits ±0.4% per GΩ | |
| 1000 V | 200 GΩ ±2% ±2 digits ±0.2% per GΩ | |
| Polarisation index (PI) | 10 min / 1 minute ratio | |
| Dielectric absorption ratio (DAR) | User configurable 15 s or 30 s t1 | |
| start time with t2 fixed at 60 s | ||
| Guard terminal performance |
<5% error at 500 kΩ parallel circuit resistance with 100 MΩ load
|
|
| Resolution | 0.1 kΩ | |
|
Short circuit/charge current
|
2 mA +0% -50% (IEC61557-2) | |
| Terminal voltage accuracy | -0% +2% ±2 V | |
| Test current |
1 mA at min. pass value of insulation to a max. of 2 mA
|
|
| Operation range | 0.10 MΩ to 1.0 GΩ (IEC61557-2) | |
| Leakage current display | 0.1 uA resolution 10% (±3 digits) | |
| Voltage display | ±3% ±2 digits ±0.5% of rated voltage | |
| Note | Above specifications only apply when high-quality silicone leads are being used - as supplied with the instrument. | |
| Continuity | ||
| Measurement | 0.01 Ω to 1 MΩ (0 to 1000 kΩ analogue scale) | |
| Accuracy | ±3% ±2 digits (0 to 99.9 Ω | |
| ±5% ±2 digits (100 Ω - 500 kΩ) | ||
| Test current | 200 mA (–0 mA +20 mA) (0.01 Ω - 4 Ω) | |
| Polarity | Single or Dual (factory default) polarity | |
| Lead resistance | Null up to 10 Ω | |
| Selectable current limit | 20 mA and 200 mA | |
| Capacitance | ||
| Range | 0.1 nF - 1 mF | |
| Accuracy | ±5.0% ±2 digits (1 nF - 10 μF) | |
| Voltmeter | ||
| Range | dc: 0 - 1000 V | |
| ac: 10 mV - 1000 V | ||
| TRMS sinusoidal (15 Hz - 400 Hz) | ||
| Accuracy | dc: ± 2% ±2 digits (0 - 1000 V) | |
| ac: ± 2% ±2 digits | ||
| (10 mV - 1000 V TRMS) | ||
| Frequency range | 15 - 400 Hz (50 mV - 1000 V) | |
| Frequency resolution | 0.1 Hz | |
| Frequency accuracy | ±0.5% ±1 digit | |
| Diode Test | Diode test accuracy: ±2% ±2 digits 0.01 V to 3.00 V | |
| Display range | 0.00 V to 3.00 V | |
| Temperature Measurement and Compensation | ||
| Thermocouple | Type T (Type K and Type J) | |
| Thermocouple range | -20 °C to 200 °C (4 °F - 392 °F) | |
| Instrument range | -20 °C to 1000 °C (4 °F - 1832 °F) | |
| Instrument resolution | 0.1 °C (0.18 °F) | |
| Instrument accuracy | ±1.0 °C ±20 digits (1.8 °F). (Basic accuracy stated assumes forward and reverse measurements.) | |
| DLRO Four-Wire Kelvin Low Resistance | ||
| Test current | 200 mA dc | |
| Range | 1 mΩ to 10 Ω | |
| Resolution | 0.01 mΩ | |
| Accuracy | ± 0.25% rdg. ± 10 digits, accuracy stated includes forward and reverse measurements. | |
| Inductance | ||
| Range | Accuracy | Test Frequency |
| 1 H | ±(0.7 % +(Lx/10000) % +5 digits) | 1 kHz |
| 200 mH | ±(1.0 % +(Lx/10000) % +5 digits) | 120 Hz |
| ±(0.7 % +(Lx/10000) % +5 digits) | 1 kHz | |
| 20 mH | ±(2.0 % +(Lx/10000) % +5 digits) | 120 Hz |
| ±(1.2 % +(Lx/10000) % +5 digits) | 1 kHz | |
| 2 mH | ±(2.0 % +(Lx/10000) % +5 digits) | 1 kHz only |
| Results Srorage | ||
| Storage capacity | 256 motor results (date / time stamped) | |
| Data download | USB Type A (USB Mass Storage Device) | |
| Power | ||
| Battery | 6 x IEC LR6 1.5 V Alkaline (AA), IEC FR6 1.5 V Lithium (LiFeS2 ), IEC HR6 1.2 V NiMH (rechargeable option). | |
| Battery life | 10 motors per (complete suite of tests at 100 V into 100 MΩ) IEC61557-2 - test cycle, 1200 insulation tests with duty cycle of 5 s testing on 25 sec standby @ 500 V into 0.5 MΩ. | |
| IEC61557-4 test cycle, 1200 continuity tests with duty cycle of 5 sec testing on 25 sec standby on 1 Ω resistance | ||
| Battery charging | Mains battery charger kit. | |
| Safety protection | IEC61010-1 CAT III 600 V | |
| EMC | Industrial IEC61326 | |
| Temperature coefficient | <0.1% per °C up to 1 GΩ | |
| Environment | ||
| Operating temperature range | -10 °C to 50 °C (14 °F to 122 °F) | |
| Storage temperature range | -25 °C to 65 °C (-13 °F to 149 °F) | |
| Humidity | 90% RH at 40 °C (104 °F) max. | |
| Calibration temperature | 20 °C (68 °F) | |
| Maximum altitude | 3000 m (9843 ft.) | |
| IP rating | IP54 | |
| Physical | ||
| Display | Full LCD colour screen with user-configurable backlight | |
| Languages | English, French, German and Spanish. | |
| Dimensions | 228 x 105 x 75 mm (8.98 x 4.1 x 2.95 in) | |
| Weight | 1.00 kg (2.2 lbs) | |
| Fuse | x2 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse, high break capacity HBC, 30 kA minimum. Glass fuses must not be installed. | |
| UK Mainland | Order by 2pm for Next Day Delivery* |
|---|---|
| Under £25.00 | £4.50 |
| Over £25.00 | FREE |
| UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
|---|---|
| Under £80.00 | £15.00 |
| Over £80.00 | FREE |