Testo 310 Flue Gas Analyser With Printer 0563 3110

£562.80
Temperature - TC Type K (NiCr-Ni)

Measuring range

-20 to +100 °C

Accuracy

±1 °C

Resolution

0.1 °C

Reaction time

< 50 s

Temperature (ambient temperature)

Temperature - TC Type J (Fe-CuNi)

Measuring range

0 to +400 °C

Accuracy

±1 °C (0 to +100 °C)

±1.5 % of mv (> 100 °C)

Resolution

0.1 °C

Reaction time

< 50 s

Temperature (flue gas)

Flue gas O₂

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

30 s

Flue gas Draught

Measuring range

-20 to +20 hPa

Accuracy

±0.03 hPa (-3.00 to +3.00 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.01 hPa

Flue gas degree of effectivity, Eta (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max (Display range)

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 40 s

Pressure measurement

Measuring range

-40 to +40 hPa

Accuracy

±0.5 hPa

Resolution

0.1 hPa

Flue gas CO (without H₂-compensation)

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time t₉₀

60 s

Ambient CO

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time

60 s

General technical data

Dimensions

201 x 83 x 44 mm

Operating temperature

-5 to +45 °C

Display type

LCD

Display function

Backlit 2-line display

Power supply

Battery: 1500 mAh, mains unit 5V/1A

Storage temperature

-20 to +50 °C

Weight

(with probe) Approx. 700 g

Description

Testo 310 Flue Gas Analyser With Printer 0563 3110

The Testo 310 Flue Gas Analyser combines simple functions with a high level of measurement accuracy, and is perfect for all basic measurements on heating systems. Long battery lifetimes of up to 10 hours guarantee high availability. It’s easy handling and compact design make the testo 310 a robust tool for daily work – even when things get rough.

With its capability to perform both basic or more complex combustion analysis, perform maintenance or safety checks, or confirm boiler efficiency, the fully featured testo 310 residential combustion analyser is ready to provide accurate analysis. The stainless steel probe and cone-stop is perfect for residential, and boiler efficiency applications. Simple top-of-display icons show you the current measurement functions. After only 30 seconds, the 310 is ready to test. With five different fuels to select from (Natural Gas, Propane, Fuel Oil 2%, Biomass 5%, Wood 20%), it provides the flexibility you need for all your residential combustion analysis applications.


Measures:

  • O2, CO (with built-in NOx filter), CO2
  • Undiluted CO (CO air free)
  • Ambient CO
  • Draft & Pressure
  • Temperature (flue & ambient)
  • Combustion/flue gas efficiency & excess air


The Testo 310 Printer Kit Comes Supplied With:

  • Testo 310 Flue Gas Analyser
  • Testo IR Printer
  • 2 Thermal Printer Rolls
  • Rechargeable Battery
  • USB Mains Cable
  • Silicon Hose for Pressure
  • 5 x Filters
  • Calibration Protocol
  • 180mm Probe with Cone
  • Spare Pressure Plugs
  • Hard Case


Applications:

 

Draught measurement in the flue gas duct

Draught measurement is actually a differential pressure measurement. This differential pressure occurs between two sub-areas as a result of a difference in temperature. This is turn generates a flow to compensate. In the case of flue gas systems, the difference in pressure is an indicator of the “chimney flue draught”. This is measured between the flue gas and ambient air at the measurement orifice at the core of the flue gas flow.

To ensure the flue gases are safely transported through the chimney there must be a differential pressure (chimney flue draught) for boiler systems that work with low pressure.
If the draught is permanently too high, the average flue gas temperature increases and therefore flue gas loss. The level of efficiency drops. If the draught is permanently too low, oxygen may be lacking during combustion, resulting in soot and carbon monoxide. This will also cause a drop in the level of efficiency.

Ambient CO measurement in the heated environment

Carbon monoxide (CO) is a colourless, odourless and taste-free gas, but also poisonous. It is produced during the incomplete combustion of substances containing carbon (oil, gas, and solid fuels, etc.). If CO manages to get into the bloodstream through the lungs, it combines with haemoglobin thus preventing oxygen from being transported in the blood; this in turn will result in death through suffocation. This is why it is necessary to regularly check CO emissions at the combustion points of heating systems, and places often frequented by people (in our case, where the combustion systems for hot water generation are), and in the surrounding areas.

Measuring the flue gas parameters of the burner (CO, O2, and temperature, etc.)

The flue gas measurement for a heating system helps to establish the pollutants released with the flue gas (e.g. carbon monoxide CO) and the heating energy lost with the warm flue gas. In some countries, flue gas measurement is a legal requirement. It primarily has two objectives:

1. Ensuring the atmosphere is contaminated as little as possible by pollutants; and

2. energy is used as efficiently as possible.

Stipulated pollutant quantities per flue gas volume and energy losses must never be exceeded.

Measurement in terms of results required by law takes place during standard operation (every performance primarily using the appliance). Using a Lambda probe (single hole or multi-hole probe), the measurement is taken at the centre of flow in the connecting pipe (in the centre of the pipe cross-section, not at the edge) between the boiler and chimney/flue. The measured values are recorded by the flue gas analyzer and can be logged either for print out or transfer to a PC at a later stage.

Measurement is taken by the installer at commissioning, and if necessary four weeks later by the flue gas inspector/chimney sweep, and then at regular intervals by the authorised service engineer.

Measuring pressure on burners (nozzle pressure, gas flow pressure, etc.)

Standard readings taken during services of domestic heating systems include checking the gas pressure on the burners. This involves measuring the gas flow pressure and gas resting pressure. The flow pressure, also called supplied pressure, refers to the gas pressure of the flowing gas and resting pressure of the static gas. If the flow pressure for gas boilers is slightly outside the 18 to 25 mbar range, adjustments must not be made and the boiler must not be put into operation. If put into operation nonetheless, the burner will not be able to function properly, and explosions will occur when setting the flame and ultimately malfunctions; the burner will therefore fail and the heating system will shut down.


ISSWWW and Testo

Testo Limited was established in 1983 as the UK subsidiary of testo and is based in Alton, Hampshire where they supply a full range of test equipment across the UK and Ireland. They are a key supplier to the Facility Management and Industrial Maintenance Sectors where they are able to provide the full range of instruments which are critical to the effective and efficient maintenance of premises, and allow compliance with all key regulations.

Testo have many innovative products to their portfolio with a modern attractive design. Aesthetic appeal isn't something usually attributed to test equipment but Testo really breaks the mould. Coupled with their pedigree as a worldwide manufacturer and supplier with a proven track record, we are confident in supplying and recommending Testo products without reservation.

Features & Specification

More Information
Key Features O2 CO (with built-in NOx filter) CO2, -20 to +20 hPa, 0 to 4000 ppm, Backlit 2-line display, Temperature (flue & ambient)
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Testo
Short Description
Temperature - TC Type K (NiCr-Ni)

Measuring range

-20 to +100 °C

Accuracy

±1 °C

Resolution

0.1 °C

Reaction time

< 50 s

Temperature (ambient temperature)

Temperature - TC Type J (Fe-CuNi)

Measuring range

0 to +400 °C

Accuracy

±1 °C (0 to +100 °C)

±1.5 % of mv (> 100 °C)

Resolution

0.1 °C

Reaction time

< 50 s

Temperature (flue gas)

Flue gas O₂

Measuring range

0 to 21 Vol.%

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

30 s

Flue gas Draught

Measuring range

-20 to +20 hPa

Accuracy

±0.03 hPa (-3.00 to +3.00 hPa)

±1.5 % of mv (Remaining Range)

Resolution

0.01 hPa

Flue gas degree of effectivity, Eta (calculated)

Measuring range

0 to 120 %

Resolution

0.1 %

Flue gas loss (calculated)

Measuring range

0 to 99.9 %

Resolution

0.1 %

Flue gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max (Display range)

Accuracy

±0.2 Vol.%

Resolution

0.1 Vol.%

Reaction time t₉₀

< 40 s

Pressure measurement

Measuring range

-40 to +40 hPa

Accuracy

±0.5 hPa

Resolution

0.1 hPa

Flue gas CO (without H₂-compensation)

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time t₉₀

60 s

Ambient CO

Measuring range

0 to 4000 ppm

Accuracy

±20 ppm (0 to 400 ppm)

±5 % of mv (401 to 2000 ppm)

±10 % of mv (2001 to 4000 ppm)

Resolution

1 ppm

Reaction time

60 s

General technical data

Dimensions

201 x 83 x 44 mm

Operating temperature

-5 to +45 °C

Display type

LCD

Display function

Backlit 2-line display

Power supply

Battery: 1500 mAh, mains unit 5V/1A

Storage temperature

-20 to +50 °C

Weight

(with probe) Approx. 700 g

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA