AttributeValue
Voltage Range 50 ~ 1000v AC
Sensitivity Indicator will illuminate at 4mm distance of a 2.5mm conductor carrying 50v
Response Time Immediate
Intrinsically Safe Yes
Power Requirements 2 x Standard AAA alkaline batteries (supplied)
Relative Humidity 80% @ 30°C, 50% @ 40°C
Operating Temperature -20 ~ +50°C
Overvoltage CATIII 1000v AC
Dimensions 145(L) x 18(Ø)mm
Weight (Net) 0.04kg

Description

SAGAB Volt Stick LV50 Non-contact Voltage Tester ATEX Approved

 

This product could save your life!

Approved for use by many of the UK's leading utilities and infrastructure providers, the Volt Stick LV50 is a high sensitivity, intrinsically-safe version of our market-leading Volt Stick non-contact voltage checker.

Companies such as Shell, Network Rail, Cadent and many more have approved the Volt Stick LV50 as the exclusive safety checking device for their field engineers to test metallic surfaces, pipework and cables to be safe from potentially lethal voltages.

The Volt Stick LV50 is sensitive down to just 50v AC allowing for instant - and potentially life-saving - identification of spurious / unexpected live voltages in materials, devices or workspaces.

Used in a wide variety of hazardous and potentially explosive atmospheres - such as gas and petrochemical applications - the LV50 is both ATEX and IECEx approved to be intrinsically-safe.

Approvals: Ex ib IIB T3 Gb, IECEx ExV 16.0018. (Click here to Download Conformity Certificates)

 

What is ATEX Approval?

ATEX is the formal name given to the two European Directives for controlling explosive atmospheres. We take an in-depth look at ATEX Approval and its requirements for equipment in hazardous areas.
Click here to find out more about intrinsically-safe devices and ATEX approval.

Who uses the Volt Stick LV50?

As the only fully ATEX and IECEx-approved device of its kind, the unique Volt Stick LV50 is specified for use by engineers in many of the UK's leading utilities and services providers including Network Rail, National Grid and Cadent.

Features:

  • ATEX and IECEx approved voltage indicator for use in explosive atmospheres

  • Voltage indicator with safety handguard to avoid unintentional contact with live conductors

  • Voltage range 50 ~ 1000v AC

  • Fully insulated for safe use

  • Insulated for safe use

  • Fully approved to IECEX 61010-1, CATIII 1000v AC

  • CE approved

About Volt Stick

Over 30 years ago Volt Stick invented the original Volt Stick tester, the worlds first non-contact voltage tester, to quickly and easily check your work space for the presence of AC voltages.
Just the size of a pen, Volt Sticks provide a convenient safety tool which can instantly detect the presence of an AC voltage without the need to make physical contact with any potential conducting surfaces or materials.

Features & Specification

More Information
Key Features CATIII 1000VAC, Ex Rated, LED Indication, Up to 600V ac, Non-Contact, Intrinsically Safe
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Sagab
Short Description
Volt Stick LV50 Ex Rated
AttributeValue
Voltage Range 50 ~ 1000v AC
Sensitivity Indicator will illuminate at 4mm distance of a 2.5mm conductor carrying 50v
Response Time Immediate
Intrinsically Safe Yes
Power Requirements 2 x Standard AAA alkaline batteries (supplied)
Relative Humidity 80% @ 30°C, 50% @ 40°C
Operating Temperature -20 ~ +50°C
Overvoltage CATIII 1000v AC
Dimensions 145(L) x 18(Ø)mm
Weight (Net) 0.04kg

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA