Beha-Amprobe 15XP-B Multimeter

£82.74
Amprobe 15XP-B Multimeter
DC Voltage  
Ranges 200mV, 2V, 20V, 200V, 1000V
Accuracy ±(0.5% rdg + 1 digit)
AC Voltage (45 to 500Hz)  
Ranges 200mV (45 to 100Hz)
2V, 20V, 200V, 750V
Accuracy ±(1.5% rdg + 5 digits)
Resolution 100μV
Input Impedance 400mV>100MΩ
4V: 10MΩ
40V to 1000V: 9.1MΩ
AC/DC Current  
Ranges 200μA, 2000μA, 20mA, 200mA
2A
Accuracy ±(1.0% rdg + 2 digits)
±(2.5% rdg + 3 digits)
Resolution 0.1μA
Input Protection 2A/1000V fast blow ceramic fuse 6.3mm x 32mm on A input
Resistance  
Ranges 200Ω 2kΩ, 20kΩ, 200kΩ, 2MΩ
2000MΩ
Accuracy ±(1.0% rdg + 4 digits)
±(5.0% rdg - 10 digits) + 20 digits
Resolution 100mΩ
Open Circuit Voltage -0.45V DC typical, (-1.2V DC on 200Ω range)
Continuity  
Audible Indication Less than 25Ω
Response Time 100ms
Diode Test  
Test Current 1.2mA (approx)
Accuracy ±(1.5% rdg + 3 digits)
Resolution 1mV
Open Circuit Voltage 3.0V DC typical
Logic Test  
Logic Trheshold 1 (High) 2.8V ± 0.8V
Logic Threshold 0 (Low) 0.8V ± 0.5V
Test Voltage TTL 5V DC
Frequency Range 20MHz
Pulse Width 25ns min
Duty Cycle Limits >30% and <70%
Indication 40ms beep a Logic 0 (low)
Non-Contact Voltage Detector  
Range 70V to 600V AC (50 to 60Hz)
Indicator Beeper + red LED indicators
General Specs  
Display 3 ½ digit LCD with max reading of 1999
Polarity Automatic, positive implied, negative polarity indication
Overrange OL or -OL is displayed
Zero Automatic
Low Battery Indication Symbol displayed when battery voltage drops below operating level
Auto Power Off Approx 10 minutes
Measurement Rate 2 times per second, nominal
Operating Environment 0 to 50°C at 70% RH
Storage Temperature -20 to 60°C, 0 to 80% RH with battery removed
Accuracy Stated accuracy at 23°C ± 5°C, <75% relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per °C (0 to 18°C, 28 to 50°C)
Altitude 2000m
Power Single standard 9V battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life 200 hours typical with carbon zinc
Dimensions (H x W x D) 155 x 72 x 32mm (6.1 x 2.83 x 1.26 inches)
Weight Approx 210g (0.46lbs) including battery
Warranty 1 year

Description

Beha-Amprobe 15XP-B Multimeter

 

Beha-Amprobe 15XP-B Comes Supplied With:

  • Magnetic holster (Magne-Grip™)
  • Shielded 4mm Test Leads
  • User Manual
 

Key Features:

  • The 15XP-B is the right choice for electronics engineers, technicians and field service
  • Autoranging display for faster measurements
  • Integrated Measurement Memory (Data Hold)
  • Auto power-off
  • TTL logic test for digital circuits
  • Non-contact voltage detection (NCV)
  • Automatic and manual range selection
  • Integrated tilt stand for easy bench use
  • Diode test for component level troubleshooting
  • Data hold freezes display to “hold" measurement reading
  • 600V AC / 600V DC—highest voltage rating in this size of meter
  • Special 2000 MΩ measurement range 
  • Voltage, current and resistance measurement
  • Acoustic Continuity Test
  • Shock-proof and impact-resistant thanks to standard protective holster

 

 

Features & Specification

More Information
Key Features Measures resistance, Measures frequency, AC/DC voltage, AC/DC current, Backlit Display, Auto and Manual Range, Data Hold Min/Max
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Amprobe
Short Description
Amprobe 15XP-B Multimeter
DC Voltage  
Ranges 200mV, 2V, 20V, 200V, 1000V
Accuracy ±(0.5% rdg + 1 digit)
AC Voltage (45 to 500Hz)  
Ranges 200mV (45 to 100Hz)
2V, 20V, 200V, 750V
Accuracy ±(1.5% rdg + 5 digits)
Resolution 100μV
Input Impedance 400mV>100MΩ
4V: 10MΩ
40V to 1000V: 9.1MΩ
AC/DC Current  
Ranges 200μA, 2000μA, 20mA, 200mA
2A
Accuracy ±(1.0% rdg + 2 digits)
±(2.5% rdg + 3 digits)
Resolution 0.1μA
Input Protection 2A/1000V fast blow ceramic fuse 6.3mm x 32mm on A input
Resistance  
Ranges 200Ω 2kΩ, 20kΩ, 200kΩ, 2MΩ
2000MΩ
Accuracy ±(1.0% rdg + 4 digits)
±(5.0% rdg - 10 digits) + 20 digits
Resolution 100mΩ
Open Circuit Voltage -0.45V DC typical, (-1.2V DC on 200Ω range)
Continuity  
Audible Indication Less than 25Ω
Response Time 100ms
Diode Test  
Test Current 1.2mA (approx)
Accuracy ±(1.5% rdg + 3 digits)
Resolution 1mV
Open Circuit Voltage 3.0V DC typical
Logic Test  
Logic Trheshold 1 (High) 2.8V ± 0.8V
Logic Threshold 0 (Low) 0.8V ± 0.5V
Test Voltage TTL 5V DC
Frequency Range 20MHz
Pulse Width 25ns min
Duty Cycle Limits >30% and <70%
Indication 40ms beep a Logic 0 (low)
Non-Contact Voltage Detector  
Range 70V to 600V AC (50 to 60Hz)
Indicator Beeper + red LED indicators
General Specs  
Display 3 ½ digit LCD with max reading of 1999
Polarity Automatic, positive implied, negative polarity indication
Overrange OL or -OL is displayed
Zero Automatic
Low Battery Indication Symbol displayed when battery voltage drops below operating level
Auto Power Off Approx 10 minutes
Measurement Rate 2 times per second, nominal
Operating Environment 0 to 50°C at 70% RH
Storage Temperature -20 to 60°C, 0 to 80% RH with battery removed
Accuracy Stated accuracy at 23°C ± 5°C, <75% relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per °C (0 to 18°C, 28 to 50°C)
Altitude 2000m
Power Single standard 9V battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life 200 hours typical with carbon zinc
Dimensions (H x W x D) 155 x 72 x 32mm (6.1 x 2.83 x 1.26 inches)
Weight Approx 210g (0.46lbs) including battery
Warranty 1 year

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA