Megger PAT410 Portable Appliance Tester 1000-745
Megger PAT140 Portable Appliance Tester | |
Electrical Supply Range | 230V ±10 @ 50/60Hz |
Continuity Test (200mA) | |
Continuity Test Voltage | 9V AC ± 10% ± 0.1V (supply: 230V 50Hz) |
Continuity Resistance Accuracy | ±5% ± 3 digits (0 to 0.49Ω) ±5% ± 5 digits (0.5 to 0.99Ω) |
Continuity Resistance Resolution | 10mΩ (1 to 19.99Ω) |
Display Range | 0 to 19.99Ω |
Insulation Test (250V and 500V) | |
Insulation Resistance Accuracy (230V) | ±2% ±5 digits (0 to 19.99MΩ) ±5% ± 10 digits (20 to 99.99MΩ) |
Insulation Resistance Resolution | 0.01MΩ |
Display Range | 0 to 99.99MΩ |
Substitute Leakage Test | |
Test Voltage and Frequency | 40V AC ±10% nominal mains frequency |
Leakage Current Accuracy | ±5% ± 5 digits |
Leakage Current Resolution | 0.01mA |
Display Range | 0 to 19.99mA |
Differential Leakage Current | |
Test Voltage | Nominal mains 110/230V AC |
Test Frequency | Nominal mains 50/60Hz |
Differential Leakage Current Accuracy | ±5% ± 0.05mA (1.0mA to 9.99mA) ±5% ± 0.1mA (0.1mA to 0.99mA) |
Resolution | 0.01mA |
Display/Measurement Range | 0.10mA to 19.99mA |
Test Duration | User-selectable from 1 sec 10 sec to infinity |
Touch Current Test | |
Test Voltage and Frequency | Nominal mains supply |
Touch Current Accuracy | ±5% ± 5 digits |
Touch Current Resolution | 0.01mA |
Display | 0 to 10mA |
Operational Test | |
Test Voltage and Frequency | Nominal mains supply |
VA Rating | 230V 3700VA 110V 1800VA |
VA Accuracy | ±5% ± 10 digits (0 to 99VA) ±5% ± 50 digits (100VA to 999VA) ±5% ± 100 digits (1000VA to 3700VA) |
Resolution | 1VA (0 to 3700VA) |
Display Range | 0 to 3990VA |
Extension Lead Test | |
Tests Performed | Bond, insulation and polarity |
Polarity Test Voltage | 12V |
Polarity checks | Lead ok Live neutral S/C Live neutral reversed Live/neutral O/C |
Portable RCD Test | |
Test Voltage and Frequency | Nominal mains supply |
Test Current Accuracy | -8% to -2% (1/2 x I) +2 to +8% (1 x I, 5 x I) |
Trip Time Accuracy | ±1% ± 5 digits |
Trip Time Resolution | 0.1ms |
Display Range | 0 to 1999ms (1/2 x I) 0 to 300ms (1 x I) 0 to 40ms (5 x I) |
Fuse Test | |
Test Voltage | 3.3V |
Warning | Audible beep if fuse is OK |
Environmental | |
Operating Temperature | -10 to 50°C |
Storage Temperature | -20 to 60°C |
Humidity | 90% RH @ -10 to 30°C 75% RH @ +30 to 50°C |
Maximum Altitude | 2000m |
Ingress Protection | IP40 |
Other | |
Weight | 2.7kg |
Dimensions | 145 (H) x 255 (W) x 320mm (L) |
Safety | IEC 61010-1: CAT II 300V |
EMC | IEC 61326-1: 2006 IEC 61326-2-2: 2005 |
Description
For a limited time ISSWWW are offering you FREE quality PAT accessories with purchases of selected
PAT testers and PAT testing kits. Simply make your selection from the drop down box below to add your bundle.
*Choose from the following:
-
Option 1) Kewtech PATLOG1 PAT Register & a set of 500 PASS and 200 FAIL labels
-
Option 2) Seaward 270A076 110V PAT adapter
-
Option 3) Kewtech KT111 fully auto-ranging Multimeter
-
Option 4) Kewtech 103 Audible Socket Tester and a Kewtech R2 Socket Testing Adapter
Megger PAT450 PAT Tester
Overview:
Three new PAT testers with full database functionality based on the well received PAT300 series. The PAT 400 series introduces a new level of convenience and speed to PAT testing using onboard test results.
PAT410 perfect for those content to bond test solely at 200 mA, The smallest, lightest of the PAT400 series weighs only 2.7 kg.
PAT420 offers bond testing at all three currents, 200 mA, 10 A and 25 A and 230 V and 110 V operation. This tester is the choice of those who are full-time industrial or commercial PAT testers.
PAT450 in addition to the three bond test and 230 V and 110 V operation this tester offers 1.5 kV and 3.0 kV flash testing making the perfect tool for hire and repair workshops.
There is a legal requirement for any landlord, employer or owner of a place of work or public place, to ensure that all electrical equipment accessible by tenants, employees or the public is maintained in a safe condition, and an acceptable method of ensuring this is by routine electrical testing. This can be performed by electrical contractors, specialist PAT testing organisations, maintenance departments, or facilities management companies.
The PAT400 range is suitable for performing portable appliance testing in locations such as hotels, public houses, schools, colleges, nurseries, shops, offices, theatres, banks, restaurants, cafés, sports and leisure facilities, cinemas, factories and hair salons etc. where high volume testing requires that accurate records may be difficult to maintain, or aided by, on-board memory and download to management software. The PAT450 is particularly suitable for use in tool-hire shops where equipment is routinely tested prior to hire, or service workshops where deep disassembly is routine, and will perform a flash test in addition to standard PAT tests.
Key Features:
■ Vast on-board memory to keep you the job longer
■ Continuous operation, no need to stop and wait for the tester to cool down
■ Instant re-start as you move from room to room testing
■ Soft keys to speed you through the testing process
■ Full PAT testing including RCD testing
■ Most productive tester in its class
Features & Specification
Key Features | Memory function, Downloadable, Colour display, QWERTY Keyboard, Fast report generation, Automatic Test Sequences | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Megger | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
DeliveryUpdated January 2024
Please note, our cut-off time is 2:00pmOrders requiring calibrationWhilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery. Bank/Public HolidaysPredicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order. *UK Mainland (Revised March 2021)
Delivery SurchargesBecause of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
Offshore ServicesAll offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles. International deliveryInternational delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk ExportAll export inquiries should be directed to the export division before placement of order. If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
|