Megger PAT410 Portable Appliance Tester 1000-745

£1,413.60
Megger PAT140 Portable Appliance Tester
Electrical Supply Range 230V ±10 @ 50/60Hz
Continuity Test (200mA)  
Continuity Test Voltage 9V AC ± 10% ± 0.1V
(supply: 230V 50Hz)
Continuity Resistance Accuracy ±5% ± 3 digits (0 to 0.49Ω)
±5% ± 5 digits (0.5 to 0.99Ω)
Continuity Resistance Resolution 10mΩ (1 to 19.99Ω)
Display Range 0 to 19.99Ω
Insulation Test (250V and 500V)  
Insulation Resistance Accuracy (230V) ±2% ±5 digits (0 to 19.99MΩ)
±5% ± 10 digits (20 to 99.99MΩ)
Insulation Resistance Resolution 0.01MΩ
Display Range 0 to 99.99MΩ
Substitute Leakage Test  
Test Voltage and Frequency 40V AC ±10% nominal mains frequency
Leakage Current Accuracy ±5% ± 5 digits
Leakage Current Resolution 0.01mA
Display Range 0 to 19.99mA
Differential Leakage Current  
Test Voltage Nominal mains 110/230V AC
Test Frequency Nominal mains 50/60Hz
Differential Leakage Current Accuracy ±5% ± 0.05mA (1.0mA to 9.99mA)
±5% ± 0.1mA (0.1mA to 0.99mA)
Resolution 0.01mA
Display/Measurement Range 0.10mA to 19.99mA
Test Duration User-selectable from 1 sec
10 sec to infinity
Touch Current Test  
Test Voltage and Frequency Nominal mains supply
Touch Current Accuracy ±5% ± 5 digits
Touch Current Resolution 0.01mA
Display 0 to 10mA
Operational Test  
Test Voltage and Frequency Nominal mains supply
VA Rating 230V 3700VA
110V 1800VA
VA Accuracy ±5% ± 10 digits (0 to 99VA)
±5% ± 50 digits (100VA to 999VA)
±5% ± 100 digits (1000VA to 3700VA)
Resolution 1VA (0 to 3700VA)
Display Range 0 to 3990VA
Extension Lead Test  
Tests Performed Bond, insulation and polarity
Polarity Test Voltage 12V
Polarity checks Lead ok
Live neutral S/C
Live neutral reversed
Live/neutral O/C
Portable RCD Test  
Test Voltage and Frequency Nominal mains supply
Test Current Accuracy -8% to -2% (1/2 x I)
+2 to +8% (1 x I, 5 x I)
Trip Time Accuracy ±1% ± 5 digits
Trip Time Resolution 0.1ms
Display Range 0 to 1999ms (1/2 x I)
0 to 300ms (1 x I)
0 to 40ms (5 x I)
Fuse Test  
Test Voltage 3.3V
Warning Audible beep if fuse is OK
Environmental  
Operating Temperature -10 to 50°C
Storage Temperature -20 to 60°C
Humidity 90% RH @ -10 to 30°C
75% RH @ +30 to 50°C
Maximum Altitude 2000m
Ingress Protection IP40
Other  
Weight 2.7kg
Dimensions 145 (H) x 255 (W) x 320mm (L)
Safety IEC 61010-1: CAT II 300V
EMC IEC 61326-1: 2006
IEC 61326-2-2: 2005

Description



For a limited time ISSWWW are offering you FREE quality PAT accessories with purchases of selected

PAT testers and PAT testing kits. Simply make your selection from the drop down box below to add your bundle.

     *Choose from the following:

  • Option 1)  Kewtech PATLOG1 PAT Register & a set of 500 PASS and 200 FAIL labels

  • Option 2)  Seaward 270A076 110V PAT adapter

  • Option 3)  Kewtech KT111 fully auto-ranging Multimeter

  • Option 4)  Kewtech 103 Audible Socket Tester and a Kewtech R2 Socket Testing Adapter




Megger PAT450 PAT Tester 

Overview:

Three new PAT testers with full database functionality based on the well received PAT300 series. The PAT 400 series introduces a new level of convenience and speed to PAT testing using onboard test results.

PAT410 perfect for those content to bond test solely at 200 mA, The smallest, lightest of the PAT400 series weighs only 2.7 kg.

PAT420 offers bond testing at all three currents, 200 mA, 10 A and 25 A and 230 V and 110 V operation. This tester is the choice of those who are full-time industrial or commercial PAT testers.

PAT450 in addition to the three bond test and 230 V and 110 V operation this tester offers 1.5 kV and 3.0 kV flash testing making the perfect tool for hire and repair workshops.

There is a legal requirement for any landlord, employer or owner of a place of work or public place, to ensure that all electrical equipment accessible by tenants, employees or the public is maintained in a safe condition, and an acceptable method of ensuring this is by routine electrical testing. This can be performed by electrical contractors, specialist PAT testing organisations, maintenance departments, or facilities management companies.

The PAT400 range is suitable for performing portable appliance testing in locations such as hotels, public houses, schools, colleges, nurseries, shops, offices, theatres, banks, restaurants, cafés, sports and leisure facilities, cinemas, factories and hair salons etc. where high volume testing requires that accurate records may be difficult to maintain, or aided by, on-board memory and download to management software. The PAT450 is particularly suitable for use in tool-hire shops where equipment is routinely tested prior to hire, or service workshops where deep disassembly is routine, and will perform a flash test in addition to standard PAT tests.

 

Key Features: 

■ Vast on-board memory to keep you the job longer
■ Continuous operation, no need to stop and wait for the tester to cool down
■ Instant re-start as you move from room to room testing
■ Soft keys to speed you through the testing process
■ Full PAT testing including RCD testing
■ Most productive tester in its class

 

Features & Specification

More Information
Key Features Memory function, Downloadable, Colour display, QWERTY Keyboard, Fast report generation, Automatic Test Sequences
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Megger
Short Description
Megger PAT140 Portable Appliance Tester
Electrical Supply Range 230V ±10 @ 50/60Hz
Continuity Test (200mA)  
Continuity Test Voltage 9V AC ± 10% ± 0.1V
(supply: 230V 50Hz)
Continuity Resistance Accuracy ±5% ± 3 digits (0 to 0.49Ω)
±5% ± 5 digits (0.5 to 0.99Ω)
Continuity Resistance Resolution 10mΩ (1 to 19.99Ω)
Display Range 0 to 19.99Ω
Insulation Test (250V and 500V)  
Insulation Resistance Accuracy (230V) ±2% ±5 digits (0 to 19.99MΩ)
±5% ± 10 digits (20 to 99.99MΩ)
Insulation Resistance Resolution 0.01MΩ
Display Range 0 to 99.99MΩ
Substitute Leakage Test  
Test Voltage and Frequency 40V AC ±10% nominal mains frequency
Leakage Current Accuracy ±5% ± 5 digits
Leakage Current Resolution 0.01mA
Display Range 0 to 19.99mA
Differential Leakage Current  
Test Voltage Nominal mains 110/230V AC
Test Frequency Nominal mains 50/60Hz
Differential Leakage Current Accuracy ±5% ± 0.05mA (1.0mA to 9.99mA)
±5% ± 0.1mA (0.1mA to 0.99mA)
Resolution 0.01mA
Display/Measurement Range 0.10mA to 19.99mA
Test Duration User-selectable from 1 sec
10 sec to infinity
Touch Current Test  
Test Voltage and Frequency Nominal mains supply
Touch Current Accuracy ±5% ± 5 digits
Touch Current Resolution 0.01mA
Display 0 to 10mA
Operational Test  
Test Voltage and Frequency Nominal mains supply
VA Rating 230V 3700VA
110V 1800VA
VA Accuracy ±5% ± 10 digits (0 to 99VA)
±5% ± 50 digits (100VA to 999VA)
±5% ± 100 digits (1000VA to 3700VA)
Resolution 1VA (0 to 3700VA)
Display Range 0 to 3990VA
Extension Lead Test  
Tests Performed Bond, insulation and polarity
Polarity Test Voltage 12V
Polarity checks Lead ok
Live neutral S/C
Live neutral reversed
Live/neutral O/C
Portable RCD Test  
Test Voltage and Frequency Nominal mains supply
Test Current Accuracy -8% to -2% (1/2 x I)
+2 to +8% (1 x I, 5 x I)
Trip Time Accuracy ±1% ± 5 digits
Trip Time Resolution 0.1ms
Display Range 0 to 1999ms (1/2 x I)
0 to 300ms (1 x I)
0 to 40ms (5 x I)
Fuse Test  
Test Voltage 3.3V
Warning Audible beep if fuse is OK
Environmental  
Operating Temperature -10 to 50°C
Storage Temperature -20 to 60°C
Humidity 90% RH @ -10 to 30°C
75% RH @ +30 to 50°C
Maximum Altitude 2000m
Ingress Protection IP40
Other  
Weight 2.7kg
Dimensions 145 (H) x 255 (W) x 320mm (L)
Safety IEC 61010-1: CAT II 300V
EMC IEC 61326-1: 2006
IEC 61326-2-2: 2005

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA