Megger PAT350 Portable Appliance Tester 1000-743

£1,284.00
Megger PAT350 Partable Appliance Tester
Electrical Supply Range  
230V AC 230V AC ±10%
110V AC 110V AC ±10%
Supply Measurement  
Voltage ±2% ± 1V
Frequency ±1% ± 0.1Hz
Bond Test  
Open Circuit Voltage 9V AC ±10% ±0.1V (Supply: 230V 50Hz)
10A Bond Test Current 10A rms ±20% ±0.5A into 0.1Ω
25A Bond Test Current 25A rms ± 5% ± 0.5A into 0.1Ω
Earth Bond Resistance Accuracy ±5% ± 3 digits (0 to 0.49Ω)
±5% ± 5 digits (0.5 to .99Ω)
Earth Bond Resistance Resolution 10mΩ (0 to 1.99Ω)
Display Range 0 to 1.99Ω
Bond Test Nulling Up to 1.00Ω
Adjustable Test Duration User selectable from 1 sec to 20 sec
Continuity Test  
Note The continuity test is a DC test performed automatically
in both positive and negative directions. The average of
the two results is shown
Continuity Test Voltage 4.0V DC -0% +10% (open circuit)
Continuity Test Current 200mA -0% + 10% ± 5mA (into 2Ω load)
Continuity Resistance Accuracy ±5% ±3 digits (0 to 0.49Ω)
±5% ±5 digits (0.5 to .99Ω)
Continuity Resistance Resolution 10mΩ (1 to 19.99Ω)
Display Range 0 to 19.99Ω
Continuity Test Nulling Up to 9.99Ω
Test Duration User selectable from 1 sec to 20 sec
Insulation Test  
Insulation Test Voltage 250V DC -0%/+25% open circuit
500V DC -0%/+25% open circuit
(500V DC across 0.5MΩ)
Insulation Resistance Accuracy (230V) ±2% ±5 digits (0 to 19.99MΩ)
±5% ± 10 digits (20 to 99.99MΩ)
Insulation Resistance Accuracy (110V) ±5 ±5 digits (0 to 10MΩ)
Insulation Resistance Resolution 0.01MΩ (0.10 to 99.99MΩ)
Display Range 0 to 99.99MΩ
Test Duration User selectable from 1 sec to 1 minutes
Substitute Leakage Test  
Test Voltage 40V AC ±10%
Test Frequency Nominal mains 50/60Hz
Leakage Current Accuracy ±5% ± 5 digits
Leakage Current Resolution 0.01mA
Display Range 0 to 19.99mA
Test Duration User selectable from 1 sec to 1 minute
Reading corrected to 230V + 10% or 110V +10% AC
Differential Leakage Current  
Test Voltage Nominal mains 110V/230V AC
Test Frequency Nominal mains 50/60Hz
Differential Leakage Current Accuracy ±5% ± 5 digits
Differential Leakage Current Resolution 0.01mA
Display Range 0 to 19.99mA
Reading corrected to 230V +10 % or 110V + 10% AC
Touch Current Test  
Test Voltage Nominal mains 1150/230V AC
Test Frequency Nominal mains 50/60Hz
Touch Current Accuracy ±5% ±5 digits
Touch Current Resolution 0.01mA
Display Range 0 to 10mA
Test Duration User selectable from 1 sec to 5 sec
Reading corrected to 230V + 10% or 110V + 10% AC
Operational Test  
Test Voltage Nominal mains 110V/230V AC
Accuracy ±5% ±10 digits (0 to 99VA)
±5% ±50 digits (100 to 999VA)
±5% ±100 digits (1000 to 3700VA)
Resolution 1VA (0 to 3700VA)
Display Range 0 to 3.99KVA
Reading corrected to 230V or 110V AC
Results show load VA
Extension Lead Test  
Polartity Test Voltage 12V
Polarity Leak OK
Live neutral S/C
Live neutral reversed
Live/neutral O/C
Flash Test  
Flash Test Voltage 1500V AC nominal for class 1
3000V AC nominal for class 2
Flash Test Current <3.5mA short circuit @ 253V primary supply voltage
Flash Test Breakdown Current Accuracy ±5% ± 5 digits
Flash Test Breakdown Current Resolution 0.01mA
Display Range 0 to 3.0mA
Test Duration User-controlled
Portable RCD Test  
RCD Test Voltage Nominal mains 110/230V
RCD Test Frequency 50Hz
Test Current Accuracy -8% to -2% (1/2 x I)
±2% to +8^ (1 x 1,5 x I)
Trip Time Accuracy ±1% ±5 digits
Trip Time Resolution 0.1ms
Display Range 0 to 1999ms (1/2 x I)
0 to 300ms (1 x I)
0 to 40ms (5 x I)
Fuse Test  
Test Voltage 3.3V
Warning Audible Beep if fuse is ok

Description



For a limited time ISSWWW are offering you FREE quality PAT accessories with purchases of selected

PAT testers and PAT testing kits. Simply make your selection from the drop down box below to add your bundle.

     *Choose from the following:

  • Option 1)  Kewtech PATLOG1 PAT Register & a set of 500 PASS and 200 FAIL labels

  • Option 2)  Seaward 270A076 110V PAT adapter

  • Option 3)  Kewtech KT111 fully auto-ranging Multimeter

  • Option 4)  Kewtech 103 Audible Socket Tester and a Kewtech R2 Socket Testing Adapter




Megger PAT350 Portable Appliance tester

 

The PAT300 series will carry out all test requirements automatically with one button press.

PAT320 is the PAT tester if you need high productivity with a tough and easy to use instrument. If you are moving into PAT testing for the first time or you don’t want the complexity of database management, PAT320 is ideal for you.

PAT350 has additional flash test functions and is the ideal tester for high throughput requirements if you work in a tool hire company or a service centre.

The PAT300 series provides outstanding productivity with the capability to test record numbers of appliances per hour.

In addition to automatic testing, the ability to run each test individually is particularly well suited to service and repair organisations carrying out fault diagnostics.

 

Key Features:

  •   Simple manual or automatic testing
  •   230 V and 110 V operation
  •   Bond testing at 25 A,10 A and 200 mA
  •   Full colour display
  •   Tests portable RCDs and extension leads
  •   Outstanding productivity

 

Overview:

An easily portable desktop appliance tester for testing the safety of portable electrical equipment to meet health and safety regulations. The PAT300 series are fully featured testers with dedicated test buttons for direct access to tests. They are designed for customers who do not require the complexity of a fully configurable database of clients and results within the tester but do need a complete range of functions to allow automatic or manual testing of the widest range of electrical assets.

There are two products in the range - the PAT320 and the PAT350. The PAT350 is identical to the PAT320, with the addition of flash-test capability for use in environments such as manufacturing, production or tool-hire shops. Simple push-button operation make the PAT300s fast and intuitive in use. All regulatory test requirements are supported, including Class I and Class II, IEC power leads, extension leads and full tests for portable RCDs. An automatic mode is available for Class I and Class II testing. In automatic mode, the tests proceed sequentially through bond, insulation and operation, indicating a pass or fail at each test.

If a fail occurs, testing is stopped. When manual testing, each test is preceded by a selection screen where the test parameters are selected, such as bond test current, insulation test voltage or leakage test type. These diagnostic buttons provide direct access to any test individually, allowing single tests to be performed following repair or a suspect result. Accessories supplied with all models include a combined earth-bond and insulation test lead, an adaptor for testing extension leads, and a carry-case convenient product and lead storage.

 

Ideal Applications:

There is a legal requirement for any landlord, employer or owner of a place of work or public place, to ensure that all electrical equipment accessible by tenants, employees or the public is maintained in a safe condition, and an acceptable method of ensuring this is by routine electrical testing. This can be performed by electrical contractors, specialist PAT testing organisations, maintenance departments, or facilities management companies.

The PAT300 range is suitable for performing portable appliance testing in locations such as hotels, public houses, schools, colleges, nurseries, shops, offices, theatres, banks, restaurants, cafés, sports and leisure facilities, cinemas, factories and hair salons etc. The PAT350 is suitable for use in tool-hire shops where equipment is routinely tested prior to hire.

Features & Specification

More Information
Key Features Colour display, Test 110v appliances, Fast report generation, Automatic Test Sequences
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Megger
Short Description
Megger PAT350 Partable Appliance Tester
Electrical Supply Range  
230V AC 230V AC ±10%
110V AC 110V AC ±10%
Supply Measurement  
Voltage ±2% ± 1V
Frequency ±1% ± 0.1Hz
Bond Test  
Open Circuit Voltage 9V AC ±10% ±0.1V (Supply: 230V 50Hz)
10A Bond Test Current 10A rms ±20% ±0.5A into 0.1Ω
25A Bond Test Current 25A rms ± 5% ± 0.5A into 0.1Ω
Earth Bond Resistance Accuracy ±5% ± 3 digits (0 to 0.49Ω)
±5% ± 5 digits (0.5 to .99Ω)
Earth Bond Resistance Resolution 10mΩ (0 to 1.99Ω)
Display Range 0 to 1.99Ω
Bond Test Nulling Up to 1.00Ω
Adjustable Test Duration User selectable from 1 sec to 20 sec
Continuity Test  
Note The continuity test is a DC test performed automatically
in both positive and negative directions. The average of
the two results is shown
Continuity Test Voltage 4.0V DC -0% +10% (open circuit)
Continuity Test Current 200mA -0% + 10% ± 5mA (into 2Ω load)
Continuity Resistance Accuracy ±5% ±3 digits (0 to 0.49Ω)
±5% ±5 digits (0.5 to .99Ω)
Continuity Resistance Resolution 10mΩ (1 to 19.99Ω)
Display Range 0 to 19.99Ω
Continuity Test Nulling Up to 9.99Ω
Test Duration User selectable from 1 sec to 20 sec
Insulation Test  
Insulation Test Voltage 250V DC -0%/+25% open circuit
500V DC -0%/+25% open circuit
(500V DC across 0.5MΩ)
Insulation Resistance Accuracy (230V) ±2% ±5 digits (0 to 19.99MΩ)
±5% ± 10 digits (20 to 99.99MΩ)
Insulation Resistance Accuracy (110V) ±5 ±5 digits (0 to 10MΩ)
Insulation Resistance Resolution 0.01MΩ (0.10 to 99.99MΩ)
Display Range 0 to 99.99MΩ
Test Duration User selectable from 1 sec to 1 minutes
Substitute Leakage Test  
Test Voltage 40V AC ±10%
Test Frequency Nominal mains 50/60Hz
Leakage Current Accuracy ±5% ± 5 digits
Leakage Current Resolution 0.01mA
Display Range 0 to 19.99mA
Test Duration User selectable from 1 sec to 1 minute
Reading corrected to 230V + 10% or 110V +10% AC
Differential Leakage Current  
Test Voltage Nominal mains 110V/230V AC
Test Frequency Nominal mains 50/60Hz
Differential Leakage Current Accuracy ±5% ± 5 digits
Differential Leakage Current Resolution 0.01mA
Display Range 0 to 19.99mA
Reading corrected to 230V +10 % or 110V + 10% AC
Touch Current Test  
Test Voltage Nominal mains 1150/230V AC
Test Frequency Nominal mains 50/60Hz
Touch Current Accuracy ±5% ±5 digits
Touch Current Resolution 0.01mA
Display Range 0 to 10mA
Test Duration User selectable from 1 sec to 5 sec
Reading corrected to 230V + 10% or 110V + 10% AC
Operational Test  
Test Voltage Nominal mains 110V/230V AC
Accuracy ±5% ±10 digits (0 to 99VA)
±5% ±50 digits (100 to 999VA)
±5% ±100 digits (1000 to 3700VA)
Resolution 1VA (0 to 3700VA)
Display Range 0 to 3.99KVA
Reading corrected to 230V or 110V AC
Results show load VA
Extension Lead Test  
Polartity Test Voltage 12V
Polarity Leak OK
Live neutral S/C
Live neutral reversed
Live/neutral O/C
Flash Test  
Flash Test Voltage 1500V AC nominal for class 1
3000V AC nominal for class 2
Flash Test Current <3.5mA short circuit @ 253V primary supply voltage
Flash Test Breakdown Current Accuracy ±5% ± 5 digits
Flash Test Breakdown Current Resolution 0.01mA
Display Range 0 to 3.0mA
Test Duration User-controlled
Portable RCD Test  
RCD Test Voltage Nominal mains 110/230V
RCD Test Frequency 50Hz
Test Current Accuracy -8% to -2% (1/2 x I)
±2% to +8^ (1 x 1,5 x I)
Trip Time Accuracy ±1% ±5 digits
Trip Time Resolution 0.1ms
Display Range 0 to 1999ms (1/2 x I)
0 to 300ms (1 x I)
0 to 40ms (5 x I)
Fuse Test  
Test Voltage 3.3V
Warning Audible Beep if fuse is ok

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA