Megger MIT525 Diagnostic Tester 1001-939
Megger MIT525 | |
Electrical Specifications | |
Voltage Input Range | 85-265 V rms, 50/60 Hz, 60 VA |
Battery | 11.1 V, 5.2 A hour, meets IEC 62133:2003 |
Battery Life | Typical capacity 6 hours continuous at 5 kV with a 100 MΩ load |
Battery Charge Time | 2.5 hours from deep discharge, 2 hours normal discharge |
30 Min. Quick Charge | 1 hour operation at 5 kV, 100 MΩ |
Test Voltages | 250 V, 500 V, 1000 V, 2500 V, 5000 V |
User Defined Test Voltage | 100 V to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, |
Accuracy (23 °C): | ±5% to 1 TΩ, ±20% to 10 TΩ |
Guard | 2% error guarding 500 kΩ leakage with 100 MΩ load |
Display Range Analogue | 100 kΩ to 10 TΩ |
Display Range Digital | 10 kΩ to 10 TΩ |
Short Circuit Current | 3 mA nominal, max. power on all loads outperforming many 5 mA testers |
Insulation Alarm | 10 kΩ to 1 TΩ |
Capacitor Charge | <3 s/μF at 3 mA to 5 kV |
Capacitance Range (above 500V) | 10 nF to 25 μF (dependant on measurement voltage) |
Capacitance Accuracy | ±10% ±5 nF |
Voltage Output Accuracy (0 to 30°C) | +4%, -0%, ±10 V nominal test voltage at 1 GΩ |
Current Measurement Range | 0.01 nA to 6 mA |
Current Measurement Accuracy (23°C) | ±5% ±0.2 nA at all voltages |
Interference (Noise) Rejection | 1 mA per 250 V up to a maximum of 3mA |
Voltmeter Range | 30 V to 660 V ac or dc, 50/60 Hz |
Voltmeter Accuracy | ±3%, ±3 V |
Timer Range | Up to 99 minutes, 15 second minimum setting |
Memory Capacity | 5½ hours continuous logging every 5 s. or 33 logged PI tests or 350 logged IR tests |
Test Regimes | IR, IR(t), DAR, PI, SV, DD, ramp test |
Interface | USB type B (device) |
Real Time Output | USB, 1 reading/second (voltage, current and resistance) |
Environmental Conditions | |
Altitude | 3000 m, CAT rating maintained >2000 m* * Test leads connected |
Operating Temperature | -20 °C to 50 °C |
Storage Temperature | -25 °C to 65 °C |
Humidity | 90% RH non-condensing at 40 °C |
Ingress Protection | IP65 (lid closed), IP40 (lid open) |
General Specifications | |
Safety | Meets the requirements of IEC 61010-1, CATIV 600 V |
EMC | Meets the requirements of IEC61326-1 |
Dimensions | L 315 mm x W 285 mm x H 181 mm |
Weight | 4.5 kg |
Description
Megger MIT525 5Kv Diagnostic Insulation Resistance Tester
Megger MIT525 Comes Supplied With:
- User guide CD
- Power lead
- 3 m leadset x 3, medium insulated clips 1002-531
- 3 m leadset x 3, large insulated clips (MIT1025 only) 1002-534
- USB cable 25970-041
- PowerDB Lite software
key Features:
- 10 TΩ (5 kV) / 20 TΩ (10 kV) max. insulation resistance
- Timed IR plus PI and DAR diagnostic tests
- Operate with dead battery when on line power/mains
- Rapid charge Li-ion battery – up to 6 hrs continuous testing (5 kV)
- Dedicated voltmeter function (30 V to 660 V)
- CATIV 600 V safety rating
- Large LCD display with automatic backlight
- Noise filter – rejects up to 3 mA noise
- High altitude operation up to 3000 m
- Dielectric Discharge (DD), Step Voltage (SV) and ramp test functions
- Advanced memory with time/date stamp, on screen recall
- Real time clock
- Download of memory via isolated USB (type B) interface (USB cable to PC)
- PowerDB Lite asset management software
Features & Specification
Key Features | Manufacturer Certificate Included, Advanced memory, Measures up to 10 TΩ , PI, DAR, DD, SV and ramp test, 5 kV insulation resistance, Fast rechargeable batteries | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Megger | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
DeliveryUpdated January 2024
Please note, our cut-off time is 2:00pmOrders requiring calibrationWhilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery. Bank/Public HolidaysPredicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order. *UK Mainland (Revised March 2021)
Delivery SurchargesBecause of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
Offshore ServicesAll offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles. International deliveryInternational delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk ExportAll export inquiries should be directed to the export division before placement of order. If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
|