Megger MIT515 5kV Resistance Tester 1001-935
Megger MT515 Go No-go Insulation ResistanceTester | |
AC Voltage (Autoranging) | 90 to 264V rms, 47 to 63Hz |
Battery Charge Time | 2.5 hours deep discharge, 2 hours normal discharge |
Battery Life | 6 hours typical continuous Testing at 5kV with 100MΩ load |
Battery Type | 11.1V, 5.2Ah lithium ion batteries (rechargeable) Meets IEC 62133:2003 |
Electrical Specs | |
Test Voltages | 250V, 500V, 1000V, 2500V, 5000V, V lock |
Lock Test Voltage | 100 V lock to 1 kV in 10 V steps, 1 kV to 5 kV in 25 V steps, 5 kV to 15 kV in 25 V steps |
Resistance Range | 10 kΩ to 15 TΩ @ 5 kV, 10 kΩ to 20 TΩ @ 10 kV, 10 kΩ to 30 TΩ @ 15 kV |
Guard Terminal Performance | Guards out parallel leakage resistance down to 250 kΩ with a maximum additional resistance error of 1% with a 100 MΩ load |
Display | Analogue: 100kΩ to 10TΩ Digital: 10kΩ to max a above |
Short Circuit/Charge Current | 3mA @ 5kV, 10kV, 15kV |
Insulation Test | Alarm: 100kΩ to 10GΩ |
Capacitor Charge | <3 s/μF at 3 mA to 5 kV |
Capacitor Discharge | <120 ms/μF to discharge from 5000 V to 50 V <250 ms/μF to discharge from 10000 V to 50 V <3500 ms/μF to discharge from 15000 V to 50 V |
Capacitance Range (with voltage set above 500V) | 10 nF to 25 μF |
Capacitance Measurement Accuracy | ±10% ±5 nF |
Current Range | 0.01 nA to 6 mA |
Current Accuracy | ±5% ±0.2 nA at all voltages (23°C) |
Interference | 3 mA from 450 V to 5 kV |
Voltmeter Range | 30V to 660V AC or DC, 45 to 65Hz |
Voltmeter Accuracy | ±3%, ±3V |
Timer Range | Up to 99 minutes 59 second, 15 second minimum setting |
Test Modes | IR, IR(t), DAR, PI |
Real Time Output | 1Hz output reading (V, I, R) |
Environmental | |
Maximum Altitude | 3000m (5kV, 10kV) |
Operating Temperature Range | -20 °C to 50 °C |
Storage Temperature Range | -25 °C to 65 °C |
Humidity | 90% RH non-condensing at 40 °C |
IP Rating | IP65 (lid closed), IP40 (lid open) |
Safety | CAT IV 600 V to 3000 m altitude |
Description
Megger MIT515 Go No-go Insulation Resistance Tester
Megger MIT515 Comes Supplied With:
- User guide CD
- Power lead
- 3 m leadset x 3, medium insulated clips 1002-531
- 3 m leadset x 3, large insulated clips (MIT1025 only) 1002-534
Key Features:
- 10 TΩ (5 kV) / 20 TΩ (10 kV) max. insulation resistance
- Timed IR plus PI and DAR diagnostic tests
- Operate with dead battery when on line power/mains
- Rapid charge Li-ion battery – up to 6 hrs continuous testing (5 kV)
- Dedicated voltmeter function (30 V to 660 V)
- CATIV 600 V safety rating
- Large LCD display with automatic backlight
- Noise filter – rejects up to 3 mA noise
- High altitude operation up to 3000 m
Features & Specification
Key Features | Manufacturer Certificate Included, Measures up to 10 TΩ , 5 kV insulation resistance, Fast rechargeable batteries | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Megger | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
DeliveryUpdated January 2024
Please note, our cut-off time is 2:00pmOrders requiring calibrationWhilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery. Bank/Public HolidaysPredicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order. *UK Mainland (Revised March 2021)
Delivery SurchargesBecause of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
Offshore ServicesAll offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles. International deliveryInternational delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk ExportAll export inquiries should be directed to the export division before placement of order. If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
|