Megger MIT 300/310 Series Insulation Continuity testers
Nominal Test Voltage MIT310, 310A, 320, 330: 1000V, 500V, 250V (DC)
MIT300: 500V, 250V (DC)
Measuring Range 10kΩ to 999MΩ on all ranges
Short Circuit Current 1.5mA nominal
Test Current on Load 1mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364)
Accuracy (at 20°C) MIT300, 310, 320, 330: ±3% ± 2 digits up to 10MΩ, ±5% up to 100MΩ, ±30% up to full scale
MIT310A: <2.5% of scale length (or 30% of reading 200kΩ to 10MΩ)
Continuity  
Measuring Range 0.01Ω to 99.9Ω (0-50Ω on analogue scale)
Open Circuit Voltage 5V ± 1V
Short Circuit Current MIT300, 310, 320, 330: 205mA + 10mA -5mA
MIT310A: 200-250mA
Continuity Accuracy MIT300, 310, 320, 330: ±3% ± 2 digits
MIT310A: ±2.5% of scale length (or 30% of reading 0.2 to 2kΩ)
Measuring Range 0-2/20/200/2kΩ
Open Circuit Voltage 1.5V ± 0.5V
Zero Offset Adjust MIT300, 310, 320, 330: 0 - 9Ω
MIT310A: 0 to 0.5Ω
Continuity Buzzer MIT300, 310: operates at <5Ω
MIT 320, 330: adjustable from 1Ω to 20Ω
MIT310A: operates at <5Ω
MIT300, 310, 320, 330: response time <20ms
MIT310: response time <100ms
Resistance Range (MIT320/330)  
Measuring Range 10Ω to 1MΩ
Open Circuit Voltage 5V
Short Circuit Current 1.5mA
Accuracy (at 20°C) ±5 ± 2 digits up to 100kΩ
Measuring Range (MIT310A) 0 to 2kΩ (refer to continuity)
Voltage Range  
Measuring Range 0 to 600V AC (50/60Hz) or DC
Accuracy (at 20°C) MIT310, 320, 330: DC or AC (50/60Hz): ±1% ± 2 digits
MIT310A: ±2.5% of scale length for 50/60Hz
Temperature Coefficient <0.1°C per °C on all ranges
Default Voltmeter  
MIT310, 320, 330 >25V AC or DC is applied display will operate as a voltmeter
MIT300 Beeps and flashes V on the display
MIT310A All modes including OFF
Test Inhibit If more than 50V is detected testing will be inhibited

Description

Megger MIT300 Insulation and Continuity Meter


The MIT300 series has applications in all aspects of domestic, commercial and industrial electrical contracting, building maintenance, testing, inspection
and servicing. Combining both Insulation testing and continuity testing, each instrument caters for all aspects of fixed wiring installations.
Further applications can be found in panel building, testing of motors, generators, switchgear and power tools, street lighting and low volume
manufacturing environments etc.

All the MIT300 (except MIT310A) range is supplied with a warranty upgradable free to a full 3 years.


Key Features:

  •   Extremely easy to use
  •   Tough rubber armoured case
  •   Self contained protective cover
  •   Live circuit warning
  •   Weatherproof to IP54
  •   Intelligent Safety System for protection.
 

Megger MIT300 Series Selection Chart


 

Features & Specification

More Information
Key Features Manufacturer Certificate Included, Resistance Measurement, Continuity Measurement
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Megger
Short Description
Megger MIT 300/310 Series Insulation Continuity testers
Nominal Test Voltage MIT310, 310A, 320, 330: 1000V, 500V, 250V (DC)
MIT300: 500V, 250V (DC)
Measuring Range 10kΩ to 999MΩ on all ranges
Short Circuit Current 1.5mA nominal
Test Current on Load 1mA at min. pass values of insulation (as specified in BS7671, HD 384 and IEC 364)
Accuracy (at 20°C) MIT300, 310, 320, 330: ±3% ± 2 digits up to 10MΩ, ±5% up to 100MΩ, ±30% up to full scale
MIT310A: <2.5% of scale length (or 30% of reading 200kΩ to 10MΩ)
Continuity  
Measuring Range 0.01Ω to 99.9Ω (0-50Ω on analogue scale)
Open Circuit Voltage 5V ± 1V
Short Circuit Current MIT300, 310, 320, 330: 205mA + 10mA -5mA
MIT310A: 200-250mA
Continuity Accuracy MIT300, 310, 320, 330: ±3% ± 2 digits
MIT310A: ±2.5% of scale length (or 30% of reading 0.2 to 2kΩ)
Measuring Range 0-2/20/200/2kΩ
Open Circuit Voltage 1.5V ± 0.5V
Zero Offset Adjust MIT300, 310, 320, 330: 0 - 9Ω
MIT310A: 0 to 0.5Ω
Continuity Buzzer MIT300, 310: operates at <5Ω
MIT 320, 330: adjustable from 1Ω to 20Ω
MIT310A: operates at <5Ω
MIT300, 310, 320, 330: response time <20ms
MIT310: response time <100ms
Resistance Range (MIT320/330)  
Measuring Range 10Ω to 1MΩ
Open Circuit Voltage 5V
Short Circuit Current 1.5mA
Accuracy (at 20°C) ±5 ± 2 digits up to 100kΩ
Measuring Range (MIT310A) 0 to 2kΩ (refer to continuity)
Voltage Range  
Measuring Range 0 to 600V AC (50/60Hz) or DC
Accuracy (at 20°C) MIT310, 320, 330: DC or AC (50/60Hz): ±1% ± 2 digits
MIT310A: ±2.5% of scale length for 50/60Hz
Temperature Coefficient <0.1°C per °C on all ranges
Default Voltmeter  
MIT310, 320, 330 >25V AC or DC is applied display will operate as a voltmeter
MIT300 Beeps and flashes V on the display
MIT310A All modes including OFF
Test Inhibit If more than 50V is detected testing will be inhibited

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA