Megger DLRO Low Resistance Ohmmeter Specifications
Physical 
Dimensions 228 x 105 x 75 mm
(8.98 x 4.1 x 2.95 in)
Display Full LCD colour screen with user-configurable backlight.
Weight 905 grams
Safety and Electrical Protection 
Safety rating CATIII 600 V / CATIV 300 V to
EN 61010, IEC 61010-031 : 2015,
IEC 61010-030.
Safety category rating valid to an altitude of 3000 m
Live voltage Active live voltage protection to
600 V between any test terminals
without blowing a fuse. Live voltage
warning on display and audible
when
>5 V is applied between any test
terminals. Fuse protected to 1000 V,
fuses are not user-changeable.
Test Current Output (Normal Resistance test mode)
Current ranges 2 A, 1 A, 100 mA, 10 mA and 1 mA
Maximum compliance output voltage 3.24 V (1 A mode) 2.2 V (2 A mode)
Current output accuracy Normal and inductive mode: ±10 %
Long lead test mode: +10 % -0%
at all battery conditions except
with low battery indication.
Thermal EMF/Seebeck effect compensation Yes, average of forward and reverse test current measurements.
Low Resistance Measurement 
Resistance measurement test modes Normal test mode, fast mΩ/long test lead mode and inductive test mode (resistance of inductive loads).
Overall resistance range 1 µΩ – 2000 Ω
Max resistance across C terminals 2 A with up to 1.1 Ω total resistance and 1 A with up to 3.2 Ω total resistance.
Basic accuracy Bi-directional test current mode: +/- 1% +/- 2 digits.
Uni-directional test current mode: +/- 1% +/- 10 digits.
Inductive mode or unidirectional mode will introduce an undefined error if an external EMF is present
Environment 
Noise immunity Less than 1% ±20 digits additional error with 80 mV peak 50/60 Hz with on-screen noise limit indicator.
Less than 1% ±20 digits additional error with 80 mV peak 400 Hz with on-screen noise limit indicator.
EMC IEC61326-1, industrial specification
IEC61326-2-2.
Dust and moisture ingress IP54 to IEC60529 in use
Altitude Operational to 3000m
Temperature Operational range 0 ºC to 50 ºC
Storage range -20 ºC to 50 ºC
Humidity Operational to 95 %
Storage to 90 %
Power Supply 
Power Supply  Rechargeable 6 x HR6 NiMH batteries with built-in fast
charge (also has the ability to use non-rechargeable alkaline AA batteries (LR6))
Battery charge time < 4 hours
Battery life >1000 bi-directional tests at 2 A auto into a 1 Ω load
Battery Charger Adapter 
Mains/line input voltage 100 to 240 V
Mains/line input frequency 47 to 63 Hz
Output 12 V DC 1.2 A 14.4 W max
Type Travel adaptor/interchangeable plug adaptor
Plug types Australia, USA, Europe and UK plugs
Connections 
Test terminals 4 X 4 mm shrouded sockets
Data USB (For firmware updates only), the user may update instrument firmware to latest version themselves
Battery charger 2.5 mm DC jack connector

Description

Megger DLRO2 low Resistance Ohmmeter 1012-280

 

Megger DLRO2 Comes Supplied With:

  • Megger DLRO2 Handheld Low Resistance Ohmmeter
  • 2m Kelvin Clip Test Lead Set (CAT IV 300 10A)
  • 2m Kelvin Probe Test Lead Set (CAT IV 300 10A)
  • 240V Charger Power Supply
  • 6x 1.2V NiMH AA 2000mAHR Batteries
  • USB Memory Stick (with User Guide)
  • Hanging Hook and Strap
  • Soft Pouch

 

Key Features:

  • New Difference Meter for quick data comparisons 
  • Use long leads at 1 A without compromising test speed 
  • Safely test the resistance of inductive loads at 1 A 
  • < 600 V active protection against inadvertent live connections without blowing a fuse 
  • Ideal for outdoor use with protection against dust and moisture to IP54 
  • Industry standard safety rated at CATIII 600 V/CATIV 300 V 

Get fast, accurate, repeatable measurements - even in noisy environments - with the DLRO2 hand-held 2 A low resistance ohmmeter. 

The DLRO2 can measure low resistance values across a wide range of applications, from railways and aircraft to industry components. This tough device comes with a brand new ‘difference’ meter that allows repetitive measurements to be easily compared with an initial reference measurement. The difference meter also translates the percentage difference to a needle/pointer movement, making the changes clear to see. 

If your applications require long test leads, then the DLRO2 can provide this without compromising test speed or safety. It has a dedicated long lead test to optimise the output, and this long test lead function is able to provide up to 1 A of test current into 4 ohms resistance. The DLRO2, with its optional cable reel test leads, is therefore ideal for testing wind turbine and avionic lightning protection applications. 

 

Resistance Measurement Ranges

Full-Scale Resistance Test Current Resolution Normal
Resistance Mode
Inductive Mode Long Test Lead
Mode (1 A only)
15000 µΩ 2.00 A 1 μΩ Yes     
120.00 mΩ 2.00 A 0.01 mΩ Yes     
1000.0 mΩ 2.00 A 0.1 mΩ Yes     
30.000 mΩ 1.00 A 0.001 mΩ Yes  Yes  Yes 
240.00 mΩ 1.00 A 0.01 mΩ Yes  Yes  Yes 
2200.0 mΩ 1.00 A 0.1 mΩ Yes  Yes  Yes 
300.00 mΩ 100 mA 0.01 mΩ Yes     
2500.0 mΩ 100 mA 0.1 mΩ Yes     
20.000 Ω 100 mA 0.001 Ω Yes  Yes   
3000.0 mΩ 10.0 mA 0.1 mΩ Yes     
24.000 Ω 10.0 mA 0.001 Ω Yes     
200.00 Ω 10.0 mA 0.01 Ω Yes  Yes   
30.000 Ω 1.00 mA 0.001 Ω Yes     
240.00 Ω 1.00 mA 0.01 Ω Yes     
2000.0 Ω 1.00 mA 0.1 Ω Yes  Yes   

 

ISSWWW and Megger

The extensive Megger product portfolio provides electrical test equipment for an exceptionally wide range of applications at any point of the electricity network. From small handheld low voltage equipment such as multifunction installation testers through to high voltage asset test equipment like insulation resistance testers, circuit breaker analysers, protection relay test systems to transformer condition measurement devices.

Megger designs and manufactures portable electrical test equipment in factories located in Germany, Sweden, the UK, and USA. Megger products help you install, improve efficiency, reduce cost and extend the life of you or your customers’ electrical assets.

Established in the late 1800s, the company has been designing and making test and measurement instruments that perform electrical measurements for preventative maintenance, troubleshooting and commissioning for decades. Megger products have supported customers all over the world to improve their facilities’ efficiency, reduce costs, extend the life of apparatus and through trending and analysis, anticipate equipment failure and future performance.
Being a brand synonymous with the industry and a cornerstone pioneer of many of today’s everyday items of test equipment, ISSWWW are proud to bring you Megger’s full range of equipment and services, now and into the future.

Features & Specification

More Information
Key Features Quick, accurate results, Large LCD Screen, Test Leads Included, Rated: IP54, Class: CATIII 600 V/CATIV 300 V , Test resistance of inductive loads at 1 A, Difference Meter for quick data comparisons
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Megger
Short Description
Megger DLRO Low Resistance Ohmmeter Specifications
Physical 
Dimensions 228 x 105 x 75 mm
(8.98 x 4.1 x 2.95 in)
Display Full LCD colour screen with user-configurable backlight.
Weight 905 grams
Safety and Electrical Protection 
Safety rating CATIII 600 V / CATIV 300 V to
EN 61010, IEC 61010-031 : 2015,
IEC 61010-030.
Safety category rating valid to an altitude of 3000 m
Live voltage Active live voltage protection to
600 V between any test terminals
without blowing a fuse. Live voltage
warning on display and audible
when
>5 V is applied between any test
terminals. Fuse protected to 1000 V,
fuses are not user-changeable.
Test Current Output (Normal Resistance test mode)
Current ranges 2 A, 1 A, 100 mA, 10 mA and 1 mA
Maximum compliance output voltage 3.24 V (1 A mode) 2.2 V (2 A mode)
Current output accuracy Normal and inductive mode: ±10 %
Long lead test mode: +10 % -0%
at all battery conditions except
with low battery indication.
Thermal EMF/Seebeck effect compensation Yes, average of forward and reverse test current measurements.
Low Resistance Measurement 
Resistance measurement test modes Normal test mode, fast mΩ/long test lead mode and inductive test mode (resistance of inductive loads).
Overall resistance range 1 µΩ – 2000 Ω
Max resistance across C terminals 2 A with up to 1.1 Ω total resistance and 1 A with up to 3.2 Ω total resistance.
Basic accuracy Bi-directional test current mode: +/- 1% +/- 2 digits.
Uni-directional test current mode: +/- 1% +/- 10 digits.
Inductive mode or unidirectional mode will introduce an undefined error if an external EMF is present
Environment 
Noise immunity Less than 1% ±20 digits additional error with 80 mV peak 50/60 Hz with on-screen noise limit indicator.
Less than 1% ±20 digits additional error with 80 mV peak 400 Hz with on-screen noise limit indicator.
EMC IEC61326-1, industrial specification
IEC61326-2-2.
Dust and moisture ingress IP54 to IEC60529 in use
Altitude Operational to 3000m
Temperature Operational range 0 ºC to 50 ºC
Storage range -20 ºC to 50 ºC
Humidity Operational to 95 %
Storage to 90 %
Power Supply 
Power Supply  Rechargeable 6 x HR6 NiMH batteries with built-in fast
charge (also has the ability to use non-rechargeable alkaline AA batteries (LR6))
Battery charge time < 4 hours
Battery life >1000 bi-directional tests at 2 A auto into a 1 Ω load
Battery Charger Adapter 
Mains/line input voltage 100 to 240 V
Mains/line input frequency 47 to 63 Hz
Output 12 V DC 1.2 A 14.4 W max
Type Travel adaptor/interchangeable plug adaptor
Plug types Australia, USA, Europe and UK plugs
Connections 
Test terminals 4 X 4 mm shrouded sockets
Data USB (For firmware updates only), the user may update instrument firmware to latest version themselves
Battery charger 2.5 mm DC jack connector

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA