Megger DLRO10X 10A Downloadable Low Resistance Ohmmeter

£4,558.80
Megger DLRO10/DLRO10X Technical Specification 
  DLRO 10 DLRO 10X
Measurement
Mode  Manual, Auto, Continuous, Inductive  Manual, Auto, Continuous, Inductive, Undirectional
Control Fully Automatic  Fully Automatic/Manual 
Speed   <3s for forward & reverse current and to display average 
 Display  
 Measurement  4 1/2 digit seven segment LED  
 Range and Safety  LED indication Large backlit LCD 
 Test Method Single cycle reversing d.c. ratiometric measurement -average result display
 Test Current
 Accuracy  ±10% 
 Stability  <10 ppm per second 
 Maximum Lead Resistance  100 mΩ total for 10 A operation irrespective of battery
condition. 
 Voltmeter Input Impedance  > 200 kΩ
Hum Rejection  Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning will show if hum or noise exceeds this level.  
 Data Transfer  - Real Time or from storage via RS232 
 Storage  - 700 tests 
 Memo Field  - Up to 200 characters per test via integral alphanumeric keypad 
 Battery Capacity 7 Ah NiMH rechargeable  
 Battery Life  Typical 1000 x 10A Tests Before Recharge 
 Recharge Via external 90 V - 260 V 50/60 Hz charger or from 12 to 15 V dc supply  
 Standard Charging Rate 2.5 hours to 90% capacity, 4 hrs for full charge  
 Temperature  +5 ºC to +45 ºC (41 ºF to 113 ºF) at full specification
-10 ºC to +50 ºC (14 ºF to 122 ºF) at reduced accuracy 
Storage Co-Efficient   -30 ºC to +70 ºC (-22 ºF to 158 ºF) 
 Slow Charging <0.01% per ºC over range 5 ºC to 40 ºC (<0.006% per ºF from 4 1ºF to 104 ºF)  
 Humidity (MAX)  +10 ºC to +45 ºC (50 ºF to 113 ºF) 
 Altitude (MAX)  90% RH @ 40 ºC (104 ºF) non-condensing 
Safety   2000 m (6562 ft) to full safety specifications 
 EMC  In accordance with IEC61010-1 600 V Category III - only when DH6 leads are used.
In accordance with IEC61326-1 
 Dimensions  220 x 100 x 237 mm (8.6 x 4 x 9.5 in) 
 Weight  2.6 kg (5 3/4 lb.) including battery module 

Description

 

Megger DLRO10X 10A Low Resistance Ohmmeter (Downloadable) Complete with Test Leads


The DUCTER DLRO10X bring new standards to low resistance measurement. Both are fully automatic instruments, selecting the most suitable test current, up to 10 A dc to measure resistance from 0.1 µΩ to 2000 Ω on one of seven ranges. For users who desire more control over the measurement process, DLRO 10X uses a menu system controlled by a two-axis paddle to allow manual selection of the test current. DLRO10X also adds real-time download of results and on-board storage for later download to a PC.

Both instruments are built into a strong, lightweight case that is equally at home in the field or in the laboratory. Light enough to be worn around the neck, they are small enough to be taken into areas which were previously too small to access. DLRO 10 uses a large, bright 4-1/2-digit LED display while DLRO 10X has a large, backlit LCD display.

 

key Features:

• Accurate results in under three seconds 
• Auto current reversal cancels standing emfs 
• Fuse protected to 600 V 
• NiMH battery reduces weight 
• 250 mW power limit (with optional override) to avoid heating the test sample 
• Automatically detects continuity in potential and current connections 
• Visible warning of high voltages present at the terminals 
• Visible warning of current flowing in the test sample 
• Multiple operating modes including fully automatic 
• Alpha-numeric keypad for entering test notes 
• User setable high and low limits 
• Autoranging with Manual option
• Printer output and memory
• Downloadable Results


Resistance Ranges Full Scale Volts Test Current
 Full Scale   Resolution   Accuracy*   Resistive   Inductive   Resistive   Inductive
1.9999 mΩ 0.1 μΩ ±0.2% ±0.2μΩ 20 mV n/a 10 A n/a
19.999 mΩ 1 μΩ ±0.2% ±2 μΩ 20 mV 20 mV 1A 1A
199.99 mΩ 10 μΩ ±0.2% ±20 μΩ 20 mV 200 mV 100mA 1A
1.9999 Ω 100μΩ ±0.2% ±0.2 mΩ 20 mV 200 mV 10mA 100mA
19.999 Ω 1 mΩ ±0.2% ±2 mΩ 20 mV 200 mV 1mA 10mA
199.99 Ω 10 mΩ ±0.2% ±20 mΩ 20 mV 200 mV 100 μA 1mA
1999.9 Ω 100 mΩ ±0.2% ±0.2 Ω 200 mV 200 mV 100 μA 100 μA

Features & Specification

More Information
Key Features Multiple operating modes, Quick, accurate results, 0.1 µΩ to 2000 Ω, Storage and download functions, Small and weighs less than 15 kg
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Megger
Short Description
Megger DLRO10/DLRO10X Technical Specification 
  DLRO 10 DLRO 10X
Measurement
Mode  Manual, Auto, Continuous, Inductive  Manual, Auto, Continuous, Inductive, Undirectional
Control Fully Automatic  Fully Automatic/Manual 
Speed   <3s for forward & reverse current and to display average 
 Display  
 Measurement  4 1/2 digit seven segment LED  
 Range and Safety  LED indication Large backlit LCD 
 Test Method Single cycle reversing d.c. ratiometric measurement -average result display
 Test Current
 Accuracy  ±10% 
 Stability  <10 ppm per second 
 Maximum Lead Resistance  100 mΩ total for 10 A operation irrespective of battery
condition. 
 Voltmeter Input Impedance  > 200 kΩ
Hum Rejection  Less than 1% ±20 digits additional error with 100 mV peak 50/60 Hz. on the potential leads. Warning will show if hum or noise exceeds this level.  
 Data Transfer  - Real Time or from storage via RS232 
 Storage  - 700 tests 
 Memo Field  - Up to 200 characters per test via integral alphanumeric keypad 
 Battery Capacity 7 Ah NiMH rechargeable  
 Battery Life  Typical 1000 x 10A Tests Before Recharge 
 Recharge Via external 90 V - 260 V 50/60 Hz charger or from 12 to 15 V dc supply  
 Standard Charging Rate 2.5 hours to 90% capacity, 4 hrs for full charge  
 Temperature  +5 ºC to +45 ºC (41 ºF to 113 ºF) at full specification
-10 ºC to +50 ºC (14 ºF to 122 ºF) at reduced accuracy 
Storage Co-Efficient   -30 ºC to +70 ºC (-22 ºF to 158 ºF) 
 Slow Charging <0.01% per ºC over range 5 ºC to 40 ºC (<0.006% per ºF from 4 1ºF to 104 ºF)  
 Humidity (MAX)  +10 ºC to +45 ºC (50 ºF to 113 ºF) 
 Altitude (MAX)  90% RH @ 40 ºC (104 ºF) non-condensing 
Safety   2000 m (6562 ft) to full safety specifications 
 EMC  In accordance with IEC61010-1 600 V Category III - only when DH6 leads are used.
In accordance with IEC61326-1 
 Dimensions  220 x 100 x 237 mm (8.6 x 4 x 9.5 in) 
 Weight  2.6 kg (5 3/4 lb.) including battery module 

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA