Megger DET4TD2 Ground Resistance Tester
Megger DET4TD2 Earth Resistance Tester | |
Ingress Protection | IP54 |
C Spike, P Stake and Noise Check | Automatic |
Noise Rejection | 40V Peak to Peak |
2-Wire, 3-Wire, 4-Wire Tests | Yes, with no shorting links required |
Instrument Output | Voltage: ± 25V or ± 50V at 128Hz Current: 4.5mA or 0.45mA |
Resistance Range | 0.01Ω to 20kΩ |
Earth Voltage Range | 0 to 100V |
Resistance Accuracy | 2P measurements: 2% ±3 digits 3P measurements: 2% ±3 digits 4P measurements: 2% ±3 digits |
Maximum Probe Resistance | Rp limit: 100 kΩ (50 V output voltage) Rc limit: 100 kΩ (50 V output voltage) Limits reduced to 50 kΩ for 25 V output voltage Limits reduced to 5 kΩ for 0.01 Ω resolution |
Ground Voltage Range | 0 to 100V AC |
Ground Voltage Accuracy | 2% ± 2V |
Display | 3 1/2 high contrast liquid crystal |
Battery Type | 8 x AA (LR6) NiMH Rechargeable Cells |
Operating Temperature Range | -15 to +55 ºC / 5 ºF to 131 ºF |
Storage Temperature Range | -40 to +70ºC / -40 ºF to 158 ºF |
Safety | Complies with the requirements of IEC61010-1 100 V CAT IV between terminal pairs.* * The CAT IV 100 V is dependant on the use of a leadset of at least this rating, for example the optional two wire leadset part number 1001-858. |
EMC | In accordance with IEC61326-1 |
Standards Compliance | Complies with the requirements of KEMA K85B. Complies with the following parts of EN61557, “Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures”. Part 1 - General requirements Part 5 - Resistance to earth |
Dimensions | 203 x 148 x 78 mm (8 x 5.8 x 3 inches) |
Weight | 1 kg (2.2lb) |
Description
Megger DET4TD2 Ground Resistance Tester 1000-347
The DET4 contractor series includes:
• DET4TD2: Dry-cell battery powered basic 4-terminal tester
• DET4TR2: Rechargeable battery powered basic 4-terminal tester
• DET4TC2: Dry-cell battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability
• DET4TCR2: Rechargeable battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability
Key Features:
• 2, 3 and 4 point testing
• Stakeless (clamp-on) testing capability
• ART (Attached Rod Technique) capability
• Multiple, user selectable test frequencies
• Resistance measurement range to 200 kΩ
• IP54 rated
• Warning indicators prevent test failure
• Simple one button operation
• Included leads, stakes, calibration certificate and rugged carry case
The DET4TD, DET4TC and DET4TCR replace the DET5/4R and DET5/4D.
Features & Specification
Key Features | Manufacturer Certificate Included, Earth Spikes Included, 2 pole testing, 3 pole testing, 4 pole testing, One Button Operation, Ground Loop Resistance | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer | Megger | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
Product Stock Status |
Next Day Delivery (subject to availability) |
DeliveryUpdated January 2024
Please note, our cut-off time is 2:00pmOrders requiring calibrationWhilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery. Bank/Public HolidaysPredicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order. *UK Mainland (Revised March 2021)
Delivery SurchargesBecause of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
Offshore ServicesAll offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles. International deliveryInternational delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk ExportAll export inquiries should be directed to the export division before placement of order. If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
|