Megger DCM1500S Solar Clamp Meter 1013-357
Megger DCM1500s Technical Specifications | |
Display count | 6,000 counts. |
Overrange display | « OL » or « -OL » |
Measurement frequency | 3 times per second |
Maximum Conductor Size of JAW | 42 mm diameter |
Dimensions (W x H x D) | 62 x 254 x 41 mm |
Weight (approx.) | 480 g (including battery) |
Low Batteries Indication | If battery voltage drops below the operating voltage, will flash. |
Power requirements | AA size battery x 2 (R6, LR6, 15D, 15A) |
Battery life | Approximately 200 hours (based on Alkaline batteries without using the backlight). |
Environmental Conditions | |
Indoor Use Only | |
Pollution degree | 2 |
Maximum Operating Altitude | 2,000 m (6562 ft) |
Operating Temperature & Relative Humidity | -10 °C ~ 10 °C, -10 °C ~ 30 °C, ≤80 % RH. 30 °C ~ 40 °C, ≤75 % RH. 40 °C ~ 50 °C, ≤45 % RH. |
Storage temperature | -20 to +60 °C, 0 to 80 % RH. (batteries not fitted) |
Vibration | Random Vibration per MIL-PRF-28800F Class 2 |
Drop Protection | 1.2 m (4 ft) drop to hardwood on concrete floor |
Safety | EN 61010-1, EN 61010-2-032, EN 61010-2-033 for CAT III 1000 V, CAT IV 600 V, EN 61326-1 |
DC mV | |||
Range | OL Reading | Resolution | Accuracy |
600.0 mV | 660.0 mV | 0.1 mV | ± (0.7% + 5D) |
DC Voltage | |||
Range | OL Reading | Resolution | Accuracy |
600.0 V | 660.0 V | 0.1 V | ± (0.7% + 2D) |
1000 V | 1100 V | 1 V | |
AC Voltage | |||
Range | OL Reading | Resolution | Accuracy |
600.0 V | 660.0 V | 0.1 V | ± (1.0% + 5D) |
1000 V | 1100 V | 1 V | |
PV DC Voltage (using PVHV1 or PVHV2 lead set) | |||
Range | OL Reading | Resolution | Accuracy |
600.0 V | 660.0 V | 0.1 V | ± (2.0% + 5D) |
2000 V | 2200 V | 1 V | |
PV AC Voltage (using PVHV1 or PVHV2 lead set) | |||
Range | OL Reading | Resolution | Accuracy |
600.0 V | 660.0 V | 0.1 V | ± (2.0% + 5D) |
1500 V | 1600 V | 1 V | |
AC/DC µA | |||
Range | OL Reading | Resolution | Accuracy |
400.0 µA | 440.0 µA | 0.1 µA | ± (1.0% + 3D) |
4000 µA | 4400 µA | 1 µA | |
AC/DC Current | |||
Range | OL Reading | Resolution | Accuracy |
60.00 A | 66.00 A | 0.01 A | ± (2.0% + 5D) |
600.0 A | 660.0 A | 0.1 A | |
1500 A | 1550 A | 1 A | |
Frequency | |||
Range | OL Reading | Resolution | Accuracy |
100.00 Hz | 100.00 Hz | 0.01 Hz | ± (0.3% + 3D) |
1000.0 Hz | 1000.0 Hz | 0.1 Hz | |
10.000 kHz | 10.000 kHz | 0.001 kHz | |
Resistance | |||
Range | OL Reading | Resolution | Accuracy |
600.0 Ω | 660.0 Ω | 0.1 Ω | ± (0.9% + 5D) |
6.000 kΩ | 6.600 kΩ | 0.001 kΩ | ± (0.9% + 2D) |
60.00 kΩ | 66.00 kΩ | 0.01 kΩ | |
600.0 kΩ | 660.0 kΩ | 0.1 kΩ | |
Diode | |||
Range | OL Reading | Resolution | Accuracy |
1.500 V | 1.550 V | 0.001 V | ± (0.9% + 2D) |
Capacitance | |||
Range | OL Reading | Resolution | Accuracy |
100.0 µF | 110.0 µF | 0.1 µF | ± (1.9% + 2D) |
1000 µF | 1100 µF | 1 µF | |
Temperature | |||
Range | OL Reading | Resolution | Accuracy |
-40.0 °C – 400.0 °C | 440.0 °C | 0.1 °C | ± (1% + 20D) |
-40.0 °F – 752.0 °F | 824.0 °F | 0.1 °F | ± (1% + 36D) |
Description
Megger DCM1500S Solar Clamp Meter 1013-357
Ideal for use in the installation, maintenance, monitoring and testing of photovoltaic systems as well standard AC or DC electrical equipment.
The DC current measurement can also be used in applications including battery monitoring, automotive, charging and load circuits, electric vehicle servicing, lift maintenance, UPS commissioning, servicing and maintenance, electro-plating plants and welding equipment servicing as well as domestic power generation from solar panels and wind-turbines.
Megger DCM1500S Comes Supplied With:
- DCM 4mm Lead Set (Inc. Probes and Crocodile Clips)
- 1013-358TP-90 Thermocouple Probe
- 1013-364PVHV1 Lead (4mm Plugs)
- 1013-362PVHV2 Lead (MC4PV Plugs)
- 1013-363Hard Carry Case
Key Features:
- 2000 V DC
- TRMS 1500 V AC
- 1500 A AC/DC
- Smart Hold
- Auto ranging
- MIN/MAX Hold
- Inrush Current
- Megger Link app compatible
- CAT IV 600V / CAT III 1000V
- Data logger
- PV test leads with MC4PV
Additional Features:
- 6,000 counts digital display
- Large white LED backlit display
- True RMS reading on ACA/ACV
- AC/DC μA Range
- Resistance, Diode, Capacitance & Frequency measurement
- °C/°F temperature function
- Inrush current
- DCA ZERO
- Torch light on trigger push
- Data Logging up to 1000 records
- Manual save mode
- Auto Power off
Description:
Measuring up to 2000 V DC and 1500 V AC (using the PVHV Leads), as well as 1500A AC or DC, the DCM1500S is ideal for use in the installation, maintenance, monitoring and testing of photovoltaic systems as well standard AC or DC electrical equipment. The meter is supplied with both standard 4mm leads as well as the new PVHV1 (4mm) and PVHV2 (MC4PV) HV lead sets.
It has a large clear backlit display and an automatic torch in the jaw to assist use in poorly lit areas. Using the free Megger Link App, the measurement value can be remotely monitored on a smart device using the built-in Bluetooth®. This will give a live trend graph and offer the ability to sample and log the values for later analysis. The smart data-hold expands the standard hold function by giving the operator an audible warning if the “held” reading increases by 50 counts or above.
Min/Max hold provides the ability to measure the maximum and minimum values over a period of time, with each value selectable in turn. Other features include a High Frequency Rejection Filter, inrush current measurement, internal data logging, a non-contact volt seek mode and manual DC Amp zeroing
In addition to voltage and current measurement the DCM1500S has the ability to measure Resistance, Diode, Capacitance, temperature and Frequency.The DCM1500S is safety rated to IEC 61010-1 and IEC/EN61010-2-033 CAT IV 600V, and CAT III 1000V
Applications:
The DCM1500S is designed to be used on electrical systems and equipment, including Solar/Photovoltaic installations where, there is a need to measure current, volts, resistance and frequency. It is therefore intended for use while installing, maintaining, fault-finding or monitoring those systems.
The tactile barrier below the jaws of the instrument ensures a safe working distance for the operator’s hand when measuring current on live uninsulated conductors, although additional personal protection must still be used. The Smart Hold allows increases in measurements to be monitored with an audible tone. The Max/Min and In-rush modes enable maximum load currents from equipment to be identified such as start-up currents to motors and heaters.
isswww and Megger
The extensive Megger product portfolio provides electrical test equipment for an exceptionally wide range of applications at any point of the electricity network. From small handheld low voltage equipment such as multifunction installation testers through to high voltage asset test equipment like insulation resistance testers, circuit breaker analysers, protection relay test systems to transformer condition measurement devices.
Megger designs and manufactures portable electrical test equipment in factories located in Germany, Sweden, the UK, and USA. Megger products help you install, improve efficiency, reduce cost and extend the life of you or your customers’ electrical assets.
Established in the late 1800s, the company has been designing and making test and measurement instruments that perform electrical measurements for preventative maintenance, troubleshooting and commissioning for decades. Megger products have supported customers all over the world to improve their facilities’ efficiency, reduce costs, extend the life of apparatus and through trending and analysis, anticipate equipment failure and future performance.
Being a brand synonymous with the industry and a cornerstone pioneer of many of today’s everyday items of test equipment, ISSWWW are proud to bring you Megger’s full range of equipment and services, now and into the future.
Features & Specification
Key Features | MeterLink™ Connectivity | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manufacturer | Megger | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Stock Status | Next Day Delivery (subject to availability) |
Delivery
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA