Martindale VI13800/2 Non Fused Voltage Indicator

£72.30
Martindale VI13800 Non Fused Voltage Indicator
Electrical
Nominal Voltage Range 50-600V AC/DC RMS
Nominal Voltage Threshold Indications 50, 100, 200, 400V DC/AC RMS
Voltage Threshold Tolerance Conforms to BS EN 61342-3:2010
Polarity and Voltage Indication ≥12V DC/AC RMS
AC/DC Voltage Detection Automatic
Range Detection Automatic
Response Time <0.1s
Frequency Range DC, 1-400Hz
Test Current <3.5mA at 600V DC/AC RMS
Duty Ratio 30s ON (operated) / 240s OFF (recovery)
Environmental
Temperature and Humidity (Operating and Storage) -10 to 55°C ≤ 85% RH
Altitude Up to 2000m
General
Power From circuit under test
Dimensions 205 (L) x 67 (W) x 27 (D)mm
Weight 130g
Includes Instructions
Safety
Conformity To BS EN 61243-3:2010 CAT IV 600V, CAT III 1000V
Class Class II, double insulation
Pollution Degree 2
IP Rating IP54
EMC BS EN 61326-1

Description

Martindale VI13800 Non Fused Voltage Indicator


The new VI13800 is identical to the industry standard VI13700 except that it doesn’t have a fuse. This is so that it will comply with BS EN61243-3 2010 which came into force in May 2013. This standard bans the use of fuses in 2 pole voltage indicators.

Key Features:

  • Industry standard voltage indicator
  • Same as VI13700 but with no fuse
  • Fully GS38 compliant
  • Heavy duty double insulated leads
  • Bright LEDs
  • Polarity Indication

Overview:

The VI13800 shows all the key safety characteristics of the older VI-13700/2. It has retractable prods, cable with an inner cover of a different colour to quickly identify damage cables and impedances at both ends to limit current flow if a lead should be broken, eg. by being sheared in a steel cabinet.

The standard relating to 2 pole voltage indicators is BS EN61243-3. All voltage indicators on the British & European market should comply. The latest version of the standard is BS EN61243-3:2010 and came fully in to force in May 2013.

The Martindale VI-13700 has been widely used for many years and as part of its design has always included a fuse in the probe to limit the current in the event of damage to the cable.

There is a technical argument that fuses in a voltage indicator can cause unreliability and any problem with the fuse could cause the voltage indicator not to indicate a hazardous voltage. In reality this risk is very small and correct proving procedures will identify the problem. None the less, because of this potential problem, BS EN61243-3 prohibits the use of fuses in 2 pole voltage indicators.

In order to fully comply with BS EN61243-3:2010 Martindale has released an updated version of VI-13700/2 with a model number of VI-13800. This new model has the fuse replaced by a high wattage resistor in the probe that will limit the current in the event of damage to the cable. This protection is superior to the protection offered by the fuse as the current that can flow under fault conditions is considerably less. The vast majority of competitor products have no protection built into the probe.

HSE Guidance note GS38 has not been revised for many years and therefore hasn’t kept pace with technology or international standards. It is due to be updated. The existing version of GS38 does not require fuses in a 2 pole voltage indicator built to a recognised standard such as BS EN61243-3.

Apart from the fuse/resistor in the probe everything else about the specification of VI-13700/2 & VI-13800 is identical, including the contrasting inner cable sheath to quickly identify cable damage.

In order to distinguish VI-13700/2 from VI-13800 the new model has the probe changed to all black instead of yellow. The probe is clearly marked “impedance protected” rather than showing a fuse rating. It is sealed and has no user replaceable parts.

There is no specific requirement to replace the VI13700 products which are in use. NB Proper proving procedures should always be used with any voltage indicator.

Features & Specification

More Information
Key Features GS38 Compliant, Current Test, LED Indicator, Indication of Polarity, Tests Up To 600v, Non-Fused
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Martindale
Short Description
Martindale VI13800 Non Fused Voltage Indicator
Electrical
Nominal Voltage Range 50-600V AC/DC RMS
Nominal Voltage Threshold Indications 50, 100, 200, 400V DC/AC RMS
Voltage Threshold Tolerance Conforms to BS EN 61342-3:2010
Polarity and Voltage Indication ≥12V DC/AC RMS
AC/DC Voltage Detection Automatic
Range Detection Automatic
Response Time <0.1s
Frequency Range DC, 1-400Hz
Test Current <3.5mA at 600V DC/AC RMS
Duty Ratio 30s ON (operated) / 240s OFF (recovery)
Environmental
Temperature and Humidity (Operating and Storage) -10 to 55°C ≤ 85% RH
Altitude Up to 2000m
General
Power From circuit under test
Dimensions 205 (L) x 67 (W) x 27 (D)mm
Weight 130g
Includes Instructions
Safety
Conformity To BS EN 61243-3:2010 CAT IV 600V, CAT III 1000V
Class Class II, double insulation
Pollution Degree 2
IP Rating IP54
EMC BS EN 61326-1

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA