Martindale TB118KITA Gas Engineer Electrical Safety Kit

£239.94
Martindale PD440S Proving Unit Specification
Output voltage 440V nominal
Output frequency 50Hz nominal
Output loading See datasheet
Temperature (Operating & Storage) -10°C to 40°C
Humidity (Operating & Storage) max. 70% R.H.
Altitude up to 2000m
Pollution Degree 2
Power 6 x 1.5V, AA alkaline batteries (IEC LR6, NEDA 15A)
Dimensions 150 x 80 x 35mm
Weight 350g approx. with batteries
Martindale VI13800 Non Fused Voltage Indicator
Electrical
Nominal Voltage Range 50-600V AC/DC RMS
Nominal Voltage Threshold Indications 50, 100, 200, 400V DC/AC RMS
Voltage Threshold Tolerance Conforms to BS EN 61342-3:2010
Polarity and Voltage Indication ≥12V DC/AC RMS
AC/DC Voltage Detection Automatic
Range Detection Automatic
Response Time <0.1s
Frequency Range DC, 1-400Hz
Test Current <3.5mA at 600V DC/AC RMS
Duty Ratio 30s ON (operated) / 240s OFF (recovery)
Environmental
Temperature and Humidity (Operating and Storage) -10 to 55°C ≤ 85% RH
Altitude Up to 2000m
General
Power From circuit under test
Dimensions 205 (L) x 67 (W) x 27 (D)mm
Weight 130g
Includes Instructions
Safety
Conformity To BS EN 61243-3:2010 CAT IV 600V, CAT III 1000V
Class Class II, double insulation
Pollution Degree 2
IP Rating IP54
EMC BS EN 61326-1
NEW

Description

Martindale TB118KITA Gas Engineer Electrical Safety Kit

The Gas Safe Register Technical Bulletin 118, originally published in January 2018, was amended in February 2023 becoming TB118a. The guidance is designed to keep service engineers safe from electrical hazards.

Martindale TB118KITA includes all the essential test tools for gas safety engineers to achieve compliance. The new kit combines easy-to-use tools for live voltage indication together with fused spur and mcb locking off devices in a high-quality soft carry case.

The all-in-one kit includes the VIPD138 voltage indicator & proving unit and the LOKKITGAS1 which enables gas service engineers to securely lock off circuits before carrying out work on appliances connected to the mains power supply. Locking off the supply is an essential step in safe isolation procedures as required by the Electricity at Work Regulations and Gas Safe Register Technical Bulletin TB118a.

TB118KITA Includes:

• PD440S 440V AC Proving Unit
• VI-13800 Industry Standard Voltage Indicator
• LOKFS1 Fused Spur Lock off device & lock Out Tag
• PAD10R Padlock with unique key
• LOK7, LOK10, LOK11 MCB locks
• TC68, TC69 Soft Carry Cases

Applications:

The Gas Safe Register’s Technical Bulletin 118 issued in January 2018 addressed test procedures to
keep service engineers safe from electrical hazards. On the 1st of February 2023, a new version of
the bulletin was issued, Technical Bulletin 118a which provides information and guidance which
relates to safe-to-touch and safe isolation procedures on single-phase supplies when carrying out gas
work.

ISSWWW and Martindale Electric

Founded in 1928 and also owns Edgcumbe Instruments Metrohm® products, as well as the John Drummond Engineers range of test lamps. They are a British-owned company, based in Watford, just 5 minutes from junction 5 of the M1. Their product range helps electricians and maintenance engineers carry out portable appliance testing, check fixed wiring for 17th Edition and Part P testing, safely prove dead, and measure everything from light and sound levels to microwave leakage and power consumption.

We are proud to be able to offer Martindale's products and services and have done so for many years. 

Features & Specification

More Information
Key Features TB118A Feb 2023 Compliant, Gas engineer's essential kit, Includes 4 lock-off devices, Voltage indicator & proving unit, Cases included
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Martindale
Short Description
Martindale PD440S Proving Unit Specification
Output voltage 440V nominal
Output frequency 50Hz nominal
Output loading See datasheet
Temperature (Operating & Storage) -10°C to 40°C
Humidity (Operating & Storage) max. 70% R.H.
Altitude up to 2000m
Pollution Degree 2
Power 6 x 1.5V, AA alkaline batteries (IEC LR6, NEDA 15A)
Dimensions 150 x 80 x 35mm
Weight 350g approx. with batteries
Martindale VI13800 Non Fused Voltage Indicator
Electrical
Nominal Voltage Range 50-600V AC/DC RMS
Nominal Voltage Threshold Indications 50, 100, 200, 400V DC/AC RMS
Voltage Threshold Tolerance Conforms to BS EN 61342-3:2010
Polarity and Voltage Indication ≥12V DC/AC RMS
AC/DC Voltage Detection Automatic
Range Detection Automatic
Response Time <0.1s
Frequency Range DC, 1-400Hz
Test Current <3.5mA at 600V DC/AC RMS
Duty Ratio 30s ON (operated) / 240s OFF (recovery)
Environmental
Temperature and Humidity (Operating and Storage) -10 to 55°C ≤ 85% RH
Altitude Up to 2000m
General
Power From circuit under test
Dimensions 205 (L) x 67 (W) x 27 (D)mm
Weight 130g
Includes Instructions
Safety
Conformity To BS EN 61243-3:2010 CAT IV 600V, CAT III 1000V
Class Class II, double insulation
Pollution Degree 2
IP Rating IP54
EMC BS EN 61326-1

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA