Martindale MTL20 Test Lamp
Martindale MTL20 Test Lamp | |
Maximum Working Voltage | 500VAC, 750DC |
Nominal Voltage Threshold Indications | 50, 100, 200, 400V AC/DC |
Nominal Voltage Threshold Tolerance | Conforms to BS EN 61243-3:2010 |
Range Detection | Automatic |
Response Time | <0.1S |
Frequency Range | DC, 40-65Hz |
Switchable Load | Approx 8.8kΩ load |
Test Current | (switches operated): approx. 28mA at 240V AC rms, DC approx. 60mA at 500V AC rms, DC |
Duty Ratio | 30s ON (operated) / 240s OFF (recovery) |
Operating and Storage Temp | -10°C to 55°C |
Operating and Storage Humidity | ≤ 85% R.H. |
Altitude | Up to 2000m |
Pollution Degree | 2 |
IP Rating | IP64 |
Power | From Circuit Under Test |
Dimensions | 213(L) x 112(W) x 72(D) mm |
Weight | 350g approx |
Safety | Conforms to BS EN 61243-3 CAT IV 600V, CAT III 1000V. Class II, Double Insulation. |
EMC | Conforms to BS EN 61326-1. |
Description
Martindale MTL20 Test Lamp
The new Drummond MTL20 test lamp safe voltage indication from 50 - 500V AC / DC. In addition to the MTL10, the new model MTL20 incorporates two test buttons, one on the body of the unit and one on the probe. Simultaneous depression of both buttons enables the unit to draw a high current, allowing the user to differentiate between phantom voltages and hazardous persistent voltages. The robust design meets the recommendations of the Health and Safety Executive in their guidance notes on the electrician's test lamp (GS38) as well as complying with BS EN 61243-3 and BS EN 61010, CAT III 1000V and CAT IV 600V.
A unique feature of this new Drummond test lamp are the four distinctive bands of illumination, with a 360° viewing angle, providing indication of voltages above 50, 100, 200 & 400 volts, even in bright sunlight. This allows for accurate identification of potentially lethal voltages at 50V and enables the user to distinguish between 110V, 230V and phase to phase voltages in a 3 phase system.
Both the lamp housing and the probe have a finger shield and insulated probe tip with only 4mm of exposed metal. A two layer double insulated cable with white inner insulation gives a clear warning of abrasion that might compromise the user's safety, and is resistant against heat and oil. To enable use in most circumstances, a right angled probe tip is supplied in addition to the two straight tips. For maximum ease of use the right angled probes can be rotated through 90, 180 and 270 degrees.
ISSWWW and Martindale Electric
Founded in 1928 and also owns Edgcumbe Instruments Metrohm® products, as well as the John
Drummond Engineers range of test lamps. They are a British owned company, based in Watford, just 5 minutes from junction 5 of the M1. Their product range helps electricians and maintenance engineers carry out portable appliance testing, check fixed wiring for 17th Edition and Part P testing, safely prove dead, and measure everything from light and sound levels to microwave leakage and power consumption.We are proud to be able to offer Martindale's products and services and have done so for many years.
Features & Specification
Key Features | GS38 Compliant, LED Indicator, Indication of Polarity | ||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Product is currently unavailable – Click Here for related products | ||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Martindale | ||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
DeliveryUpdated January 2024
Please note, our cut-off time is 2:00pmOrders requiring calibrationWhilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery. Bank/Public HolidaysPredicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order. *UK Mainland (Revised March 2021)
Delivery SurchargesBecause of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
Offshore ServicesAll offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles. International deliveryInternational delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk ExportAll export inquiries should be directed to the export division before placement of order. If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
|