Martindale DT175 Dual Input K Type Digital Thermometer

£107.94

Martindale DT175 Single Input K Type Digital Thermometer

Electrical
Temperature coefficient 0.1 x (applicable accuracy) per °C. (0°C to 18°C, 28°C to 50°C)
Temperature scale Celsius or Fahrenheit, user-selectable
Thermocouple type K
Measurement range -200°C to 1372°C. (-328°F to 1999°F)
Note Measurement range will be limited by the range of the thermocouple probe used.
Resolution 0.1° to 199.9°C/°F, 1° t 200°C/°F
Temperature accuracy
-200°C to -60°C ± (0.1% of rdg + 2°C)
-60°C to 1372°C ± (0.1% of rdg + 1°C)
-328°F to -76°F ± (0.1% of rdg + 4°F)
-76°F to 1999°F ± (0.1% of rdg + 2°F)
Input protection 24V DC or AC rms maximum input voltage on
any combination of input pins.
Input connector  Accepts standard miniature thermocouple connectors
(fl at blades spaced 7.9mm. center to center).
Supplied thermocouple probe 4-foot Type K thermocouple bead probe (tefl on tape insulated).
 Maximum insulation temperature: 260°C (500°F).
 Probe accuracy: ± 2.2°C or ± 0.75% of reading (whichever is
greater).
General
Display 3.5” digit LCD with a maximum reading of 1999
Measurement rate 2.5 times/second
Polarity  Automatic, positive implied, ‘-‘ for negative polarity indication
Overrange (OL) is displayed
Power  4 x 1.5V, AAA alkaline batteries (IEC LR03, NEDA 24A)
Battery life 200 hours typical with alkaline batteries
Low battery indication Low battery symbol is displayed
Auto power off After 30 minutes
Dimensions 160 mm (H) x 83 mm (W) x 38 mm (D)
Weight Approx. 240g, including batteries
Includes Type K bead thermocouple (x2 for DT175), 4 x 1.5V AAA
alkaline batteries and instructions
Environmental
Temperature & Humidity (Operating)  0°C to 50°C, <70% R.H
Temperature & Humidity (Storage)  -20°C to 60°C, 0 to 80% R.H., batteries removed
Altitude up to 2000m
Pollution degree 2
Safety
Corforms to BS EN 61010-1
Insulation Class II, double insulation
EMC
Conforms to BS EN 61326-1

Description

Martindale DT175 Dual Input K Type Digital Thermometer

The Martindale DT175 Dual-Channel Thermometer is a high-performance temperature measurement instrument that can work with type K thermocouples.

It is capable of measuring temperature in a variety of media with a basic accuracy of ±0.3% + 1˚C and a resolution of 0.1˚C / 1˚C. It is supplied with two thermocouples which have measurement ranges of 0 to 260˚C.

Differential measurement allows the user to see the difference between the input and output temperatures of various systems. Otherwise, the Martindale DT175 can check the real temperature from each probe and it is also possible to toggle between Celsius and Fahrenheit. The user has the option of min/max/average recording and performance is enhanced by the offset adjustment function. Results are shown on a backlit digital screen.

A stand is integrated into the Martindale DT175 for additional practicality and using the thermometer is easy thanks to the clearly-labelled buttons. Supplied accessories include two type K thermocouples, a protective holster, batteries and an instruction manual.

The Martindale DT175 Is Supplied With:

  • Martindale DT175 Single Input K Type Digital Thermometer
  • 2 x K Type Bead Thermocouple 
  • 4 x 1.5V AAA Alkaline Batteries
  • Instructions Manual

Key Features:

  • Differential pressure measurement
  • Displays Temperature in °C or °F
  • Maximum temperature range: -200˚C to 1372˚C
  • Temperature accuracy: ±1˚C
  • Temperature resolution: 0.1˚C / 1˚C
  • 2 x Type K probes supplied (0 to 260˚C)
  • Min/max/average recording
  • Measurement rate: 3 per second
  • 200-hour battery life

ISSWWW and Martindale Electric

Founded in 1928 and also owns Edgcumbe Instruments Metrohm® products, as well as the John
Drummond Engineers range of test lamps. They are a British owned company, based in Watford, just 5 minutes from junction 5 of the M1. Their product range helps electricians and maintenance engineers carry out portable appliance testing, check fixed wiring for 17th Edition and Part P testing, safely prove dead, and measure everything from light and sound levels to microwave leakage and power consumption.

We are proud to be able to offer Martindale's products and services and have done so for many years.

Features & Specification

More Information
Key Features -200°C to 1372°C, Type K Connection, Dual Input, Standard Probe Included, Displays Temperature in °C or °F
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Martindale
Short Description

Martindale DT175 Single Input K Type Digital Thermometer

Electrical
Temperature coefficient 0.1 x (applicable accuracy) per °C. (0°C to 18°C, 28°C to 50°C)
Temperature scale Celsius or Fahrenheit, user-selectable
Thermocouple type K
Measurement range -200°C to 1372°C. (-328°F to 1999°F)
Note Measurement range will be limited by the range of the thermocouple probe used.
Resolution 0.1° to 199.9°C/°F, 1° t 200°C/°F
Temperature accuracy
-200°C to -60°C ± (0.1% of rdg + 2°C)
-60°C to 1372°C ± (0.1% of rdg + 1°C)
-328°F to -76°F ± (0.1% of rdg + 4°F)
-76°F to 1999°F ± (0.1% of rdg + 2°F)
Input protection 24V DC or AC rms maximum input voltage on
any combination of input pins.
Input connector  Accepts standard miniature thermocouple connectors
(fl at blades spaced 7.9mm. center to center).
Supplied thermocouple probe 4-foot Type K thermocouple bead probe (tefl on tape insulated).
 Maximum insulation temperature: 260°C (500°F).
 Probe accuracy: ± 2.2°C or ± 0.75% of reading (whichever is
greater).
General
Display 3.5” digit LCD with a maximum reading of 1999
Measurement rate 2.5 times/second
Polarity  Automatic, positive implied, ‘-‘ for negative polarity indication
Overrange (OL) is displayed
Power  4 x 1.5V, AAA alkaline batteries (IEC LR03, NEDA 24A)
Battery life 200 hours typical with alkaline batteries
Low battery indication Low battery symbol is displayed
Auto power off After 30 minutes
Dimensions 160 mm (H) x 83 mm (W) x 38 mm (D)
Weight Approx. 240g, including batteries
Includes Type K bead thermocouple (x2 for DT175), 4 x 1.5V AAA
alkaline batteries and instructions
Environmental
Temperature & Humidity (Operating)  0°C to 50°C, <70% R.H
Temperature & Humidity (Storage)  -20°C to 60°C, 0 to 80% R.H., batteries removed
Altitude up to 2000m
Pollution degree 2
Safety
Corforms to BS EN 61010-1
Insulation Class II, double insulation
EMC
Conforms to BS EN 61326-1

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA