Kewtech Kew-mate 2012RA Digital Multimeter With AC/DC Clamp Sensor

£148.32
Kewtech 2012RA Technical Specification
DC V 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±1.0%rdg±3dgt
AC V 6.000/60.00/600.0V (Input impedance: approx.10MΩ)
±1.5%rdg±5dgt (45 - 400Hz)
DC A 60.00/120.0A
±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A)
AC A 60.00/120.0A
±2.0%rdg±5dgt (45 - 65Hz)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±1.0%rdg±5dgt (600Ω/6/60/600kΩ)
±2.0%rdg±5dgt (6MΩ)
±3.0%rdg±5dgt (60MΩ)
Continuity buzzer Buzzer sounds below 35±25Ω
Diode test 2.000V±3.0%rdg±5dgt Open-loop voltage: approx. 2.7V
Capacitance 400.0nF/4.000/40.00µF
±2.5%rdg±10dgt
Frequency (AC A)
99.99/400.0Hz ±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (400Hz)
(AC V)
99.99/999.9Hz/9.999/99.99/300.0kHz ±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz)
(Input sensitivity
Current: more than 6A
Voltage: more than 6V [- 10kHz]/more than 20V [10k - 300kHz])
Conductor size Ø12mm max.
Applicable standards IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581(RoHS)
Power source R03 (AAA)(1.5V) × 2
* Continuous measuring time:
DCV: approx. 150hours, ACA: approx. 25hours
(Auto power save: approx. 15 minutes)
Dimensions 128 (L) × 92 (W) × 27 (D) mm
Weight 220g approx. (including batteries)
Included Accessories R03 (AAA) × 2, Instruction manual
Optional Accessories 9107 (Carrying case [Soft])
NEW

Description

Kewtech 2012RA Digital Multimeter With AC/DC Clamp Sensor

The Kyoritsu 2012RA is a TRMS digital multimeter that can measure both voltage and current. Compact and easy to use, this traditional style multimeter is supplied with a 12mm AC/DC clamp sensor. The Kyoritsu 2012RA can measure AC and DC voltage up to 600V, as well as resistance up to 60MΩ. Currents, both AC and DC, can also be measured up to 120A, in which the true RMS function can be applied to achieve greater accuracy across non-sinusoidal waveforms. Measured values can be held using the data-hold function.

The 2012RA model features an auto-power save function, the ability to perform a diode test, as well as measuring capacitance up to 40μF.  A continuity buzzer, which provides an audible warning below 35Ω, is also present on the meter. The Kyoritsu 2012RA includes an AC/DC clamp sensor, batteries and an instruction manual.
Because the 2012RA supports true RMS measurements, it is particularly good at providing accurate measurements in the presence of harmonics. Therefore, this meter is perfectly suited for work with photovoltaic installations, inverters, fluorescent lamps, and UPS's. All these functionalities together make for a very versatile multimeter.

Testing parameters:

  • True RMS measurements.
  • AC and DC voltage up to 600V.
  • AC and DC current up to 120A.
  • Resistance up to 60MΩ.
  • Continuity test buzzer (warns below 35Ω).
  • Capacitance up to 40μF.
  • Diode test function.
  • Auto-power save.

Key Features:

  • Innovative Multimeters with current measurements up to 120A AC/DC
  • Unique Open Jaw technology for AC/DC current measurements
  • Very compact and as reliable as a traditional full-size multimeter
  • Pocket size and heavy-duty design.
  • Increased cable strength with new rubber protection
  • Test probe can be fixed to the holster.
  • Can measure AC/DC current and voltage.
  • With test lead cap to protect from short circuit accidents.
  • The open jaws are thin, and perfect for clamping wires even in tight spaces.

Applications:

  • Everyday multimeters for technicians, the Kewmates are designed for electrical and electronic testing in field service and all applications where extra features, such as AC/DC current measurements up to 60/100/120A, simplify working.
  • Ideal for electrical and electronic troubleshooting in residential, commercial and industrial installations.
  • Thanks to the open clamp sensor, Kewmates are perfect for reading currents in tight spaces where a normal clamp meter would be unsafe or too big to use such as sub-distribution boards, consumer units, final circuits, connection boxes, control panels or simply where the wires are too short.
  • Optimized for measuring the output of a solar panel in photovoltaic installations.
  • DC current measurements permit electrical testing and servicing of cars, electric forklifts, small electric cars or trolleys for cleaning, DC motor adjustable speed controllers, golf cars and trolleys, small electric cars and chairlifts for the disabled, work platforms, UPS's, electric scooters and bikes, etc.

Application Examples:

Product Comparison Chart:

The Kew-mate comes in three variations, choose the correct model for you from the table below.

  2000A 2001A 2012RA
DC V 340.0mV/3.400/34.00/340.0/600V (Input impedance: 10MΩ)
±1.5%rdg±4dgt
600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±1.0%rdg±3dgt
AC V 3.400/34.00/340.0/600V (Input impedance: 10MΩ)
±1.5%rdg±5dg (50 - 400Hz)
6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±1.5%rdg±5dgt (45 - 400Hz)
DC A 60.0A
±2.0%rdg±5dgt
100.0A
±2.0%rdg±5dgt
60.00/120.0A
±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A)
AC A 60.0A
±2.0%rdg±5dg (50/60Hz)
100.0A
±2.0%rdg±5dg (50/60Hz)
60.00/120.0A
±2.0%rdg±5dgt (45 - 65Hz)
Ω 340.0Ω/3.400/34.00/340.0kΩ/3.400/34.00MΩ
±1.0%rdg±3dg (340Ω/3.4/34/340kΩ)
±5.0%rdg±5dg (3.4MΩ)
±15.0%rdg±5dg (34MΩ)
600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±1.0%rdg±5dgt (600Ω/6/60/600kΩ)
±2.0%rdg±5dgt (6MΩ)
±3.0%rdg±5dgt (60MΩ)
Continuity buzzer Buzzer sounds below 30±10Ω Buzzer sounds below 35±25Ω
Diode test 2.000V ±3.0%rdg±5dgt, Open-loop voltage: approx. 2.7V
Capacitance 400.0nF/4.000/40.00μF
±2.5%rdg±10dgt
Frequency (AC A)
(AC V)
3.400/10.00kHz
±0.1%rdg±1dgt 3.400/34.00/300.0kHz
±0.1%rdg±1dgt
  (AC A)
(AC V)
99.99/400.0Hz
±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (400Hz) 99.99/999.9Hz/9.999/99.99/300.0kHz
±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10/100/300kHz)
Input sensitivity Current: more than 15A
Voltage: more than 30V
Current: more than 25A
Voltage: more than 30V
Current: more than 6A
Voltage: more than 6V [-10kHz]/more than 20V [10k - 300kHz])
Conductor size ø6 mm max. ø10 mm max. ø12 mm max.
Applicable standards IEC 61010-1 CAT300V, CAT600V Pollution degree 2, IEC 61010-2-032, IEC 61010-031, IEC 61326-1, EN 50581(RoHS)
Power source R03(AAA)(1.5V) × 2
* Continuous measuring time: approx. 45hours (Auto power save: approx. 10 minutes)
R03(AAA)(1.5V) × 2
* Continuous measuring time:
DC V: approx. 150 hours, AC A: approx. 25 hours (Auto power save: approx. 15 minutes)
Dimensions 128(L) × 87(W) × 24(D) mm 128(L) × 92(W) × 27(D) mm
Weight 210g approx. (including batteries) 220g approx. (including batteries)
Accessories R03(AAA) × 2, Instruction manual
Optional 9107 (Carrying case [Soft])

isswww and Kewtech

One of our longest-standing manufacturer partnerships and a brand that sells well day in and day out for solid dependability and innovation at the price point. 

Kewtech manufactures innovative, accurate, and reliable test equipment that enables UK electrical contractors to undertake their testing obligations quickly and efficiently.  

A product with the “Kewtech” brand has been specifically designed for the UK market by a team with many years of industry experience. We pride ourselves on developing and manufacturing products that have real benefits to the industry. 

Kewtech has consistently introduced industry firsts, like our Lightmate testing adaptors, the Pat Adaptor, the MFT with PAT testing plus download, and our award-winning RB1 Replacement Lamp. Our 18th Edition multifunction testers lead the way in ease of use, loop accuracy, and repeatability of reading. 

Features & Specification

More Information
Key Features AC/DC clamp sensor, TRMS Measurements, Measures up to 600V AC and DC, Measures up to 120A AC and DC, Measures Resistance up to 60MΩ, Continuity test buzzer, Measures Capacitance up to 40μF, Diode test function
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Kewtech
Short Description
Kewtech 2012RA Technical Specification
DC V 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10MΩ)
±1.0%rdg±3dgt
AC V 6.000/60.00/600.0V (Input impedance: approx.10MΩ)
±1.5%rdg±5dgt (45 - 400Hz)
DC A 60.00/120.0A
±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A)
AC A 60.00/120.0A
±2.0%rdg±5dgt (45 - 65Hz)
Ω 600.0Ω/6.000/60.00/600.0kΩ/6.000/60.00MΩ
±1.0%rdg±5dgt (600Ω/6/60/600kΩ)
±2.0%rdg±5dgt (6MΩ)
±3.0%rdg±5dgt (60MΩ)
Continuity buzzer Buzzer sounds below 35±25Ω
Diode test 2.000V±3.0%rdg±5dgt Open-loop voltage: approx. 2.7V
Capacitance 400.0nF/4.000/40.00µF
±2.5%rdg±10dgt
Frequency (AC A)
99.99/400.0Hz ±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (400Hz)
(AC V)
99.99/999.9Hz/9.999/99.99/300.0kHz ±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz)
(Input sensitivity
Current: more than 6A
Voltage: more than 6V [- 10kHz]/more than 20V [10k - 300kHz])
Conductor size Ø12mm max.
Applicable standards IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581(RoHS)
Power source R03 (AAA)(1.5V) × 2
* Continuous measuring time:
DCV: approx. 150hours, ACA: approx. 25hours
(Auto power save: approx. 15 minutes)
Dimensions 128 (L) × 92 (W) × 27 (D) mm
Weight 220g approx. (including batteries)
Included Accessories R03 (AAA) × 2, Instruction manual
Optional Accessories 9107 (Carrying case [Soft])

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.