KANE International INF165C Infrared Thermometer
KANE INF165C Infrared Thermometer | |
Measurement range | -76 ~ 1022˚F (-60 ~ 550˚C) |
Operating range | 32˚ ~ 122˚F (0 ~ 50˚C) |
Accuracy (Tobj= 15~35˚C, Tamb=25˚C) | ±2.7% (1.5˚C) |
Accuracy (Tamb=23 ± 3˚C) | Tobj=0~550˚C: ±2% of reading or 2˚C (4˚F) whichever is greater Tobj=-60~0˚C: ±(2˚C+0.05/degree C) |
Emissivity | Fixed 0.95 |
Resolution | 0.1˚F/0.1˚C at -76 to 999.9 (˚F/ ˚C), otherwise 1˚F/1˚C |
Response Time (90%) | 1 second |
Distance: Spot | 12:1 |
Battery life | Typ. 14 hours 18 minutes continuous use |
Dimensions | 6.12” X 1.57” X 4.45” (155.5 X 40 X 113mm) |
Weight | 6.1 oz (173g) including batteries (AAA x 2pcs) |
Auto shut off | 15 Seconds |
Description
KANE International INF165C Infrared Thermometer
Kane INF165C lightweight infra-red thermometer with circular laser targeting and backlit display. Non-contact temperature measurement, ideal for HVAC and industrial applications.
Infrared Thermometers measure the amount of thermal radiation emitted from an objects surface. To take a measurement, the object must be within the field of view of the infrared thermometer, or the reading may include objects surrounding your target. This target size is determined in the distance to spot ratio stated on the instruments specifications. At a ratio of 10:1, a distance from your target of ten feet will give you a circle with one foot diameter. At 20:1 ratio gives the same one foot target now at 20 feet, so you can see that higher is better, but typically more expensive due to the cost of the optics involved.
The other common question is regarding emissivity. In simple terms emissivity is a percentage of energy emitted from a surface compared to the energy emitted from a black body source. If a surface emits one half (1/2 or 0.5) the amount of energy at a given temperature & wavelength as a black body, it is said to have an emissivity of 0.5.
Surfaces closest to the black body level would be flat black, & those farthest from it would be mirror or chrome surfaces. With a set emissivity level some surfaces may measure lower than actual, because their surface is emitting less thermal radiation at a given temperature. Although you may have a fixed emissivity of 0.95, most items measured will provide a reasonably accurate result. Having a fully adjustable emissivity will give you the ability to fine tune your instrument to a specific application.
Key Features:
- Temperature Range 76 ~ 1022 ̊F (-60 ~ 550 ̊C)
- Circular laser targeting
- Distance to Spot ratio: 12:1
- Fixed Emissivity 0.95
- Max value capture
- Auto off
ISSWWW and KANE International
Since 1963, Kane International Ltd has been in Welwyn Garden City, Hertfordshire, and has a long history and broad experience designing and manufacturing portable test equipment.
Kane International is the UK’s foremost manufacturer and supplier of hand-held exhaust emissions testers and portable test equipment. Kane’s design, engineering and manufacturing skills have created a range of highly sought-after portable equipment meeting the highest standards of testing and conformity. Their customers range across Commercial and Domestic Heating Engineers, Automotive Technicians to Electrical Engineers.
Specialist Instrument Services bring you the complete range of KANE products and services and also offer both industry standard traceable and UKAS calibration if required.
Features & Specification
Key Features | Auto Power Off, Backlit LCD Display, Circular Laser Targeting, Distance to Spot ratio: 12:1, Max Value Capture, Range -60 to 550 ̊C | ||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||||||||||||||
Manufacturer | Kane International | ||||||||||||||||||||||||||||||||||||
Short Description |
DeliveryUpdated January 2024
Please note, our cut-off time is 2:00pmOrders requiring calibrationWhilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery. Bank/Public HolidaysPredicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order. *UK Mainland (Revised March 2021)
Delivery SurchargesBecause of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
Offshore ServicesAll offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles. International deliveryInternational delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk ExportAll export inquiries should be directed to the export division before placement of order. If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
|