Fluke Zeroing Adapter for 1650 and 1660 Series Multifunction Testers

£51.54

Fluke 1650 Series

AC Voltage Measurement Range:  500 V
Resolution:  0.1 V
Accuracy (50 - 60 Hz)  ± (0.8% + 3 digits)
Input Impedance  3.3 MΩ
Overload Protection  660 Vrms
Continuity Testing Range (autoranging):  20 Ω, 200 Ω, 2000 Ω
Resolution:  0.01 Ω, 0.1 Ω, 1 Ω
Test Current:  > 200 mA
Open Circuit Voltage:  > 4 V
Accuracy:  ± (1.5%+3 digits)
Insulation Resistance Measurement Test Voltage:  
Fluke 1652C:  250 - 500 - 1000 V
Fluke 1653B + 1654B:  50 - 100 - 250 - 500 - 1000 V
 
   
Test Voltage:  50 V
Test Current:  1 mA @ 50 kΩ
Insulation Range:  10 kΩ - 50 мΩ
Resolution:  0.01 мΩ
Accuracy:  ± (3% + 3 digits)
   
Test Voltage:  100 V
Test Current:  1 mA @ 100 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  100 MΩ/0.1 MΩ
Accuracy:  ± (3% + 3 digits)
   
Test Voltage:  250 V
Test Current:  1 mA @ 250 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
   
Test Voltage:  500 V
Test Current:  1 mA @ 500 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
Range/Resolution:  500 MΩ/1 MΩ
Accuracy:  10%
   
Test Voltage:  1000 V
Test Current:  1 mA @ 1 MΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
Range/Resolution:  500 MΩ/1 MΩ
Accuracy:  10%
   
Auto Discharge:  Discharge time constant, 0.5 second for C = 1 µF or less
Live Circuit Detection:  Inhibits test if terminal voltage > 30 V prior to initiation of test
Maximum Capacitive Load:  Operable with the 5 µF load
Loop Impedance Measurement (High Current Mode and Non-Trip Mode) Range:  100 - 500 VAC (50/60 Hz)
Input connection:  Soft Key selection
Loop impedance:  Phase to earth
Line impedance:  Phase to neutral
Limit on consecutive tests:  Automatic thermal shutdown after 50 consecutive tests at 10 second intervals (typical)
 
Max. Test Current High Current Mode:  
Non-Trip Mode:  
 
Range/Resolution (High Current):  20 Ω/0.001Ω (1mΩ) (Fluke 1654B)
Range/Resolution:  20 Ω/0.01 Ω
Range/Resolution:  200 Ω/0.1 Ω
Range/Resolution:  2000 Ω/1 Ω
 
Accuracy (no Trip mode):  ± (3% + 6 digits)
Accuracy (Hi Current mode):  ± (2% + 4 digits)
Accuracy (Hi Current mode 1mΩ):  ± (2% + 15 digits) (Fluke 1654B)
PFC, PSC Test
Computation:  PFC or PSC determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance
Range:  0 - 25 kA
Resolution (Ik < 1000 A):  1 A
Resolution (Ik >= 1000 A):  0.1 kA
Accuracy:  Determined by accuracy of loop resistance and mains voltage measurements.
RCD Testing ¹
Fluke 1654B:  A, AC, B, B+, F, G/R, S
Fluke 1652C:  A, AC, F, G/R, S
Fluke 1653B:  A, AC, F, G/R, S
Tripping Time Test (ΔT) Trip Time Accuracy  ±(1% Reading + 1 digit)
 
Multiplier:  x ½
Current Settings:  10, 30, 100, 300, 500, 1000 mA
Current Accuracy:  +0% - 10%
RCD Type ¹:  G
Measurement Range:  310 ms (Europe), 2000 ms (UK)
RCD Type ¹:  S
Measurement Range:  510 ms (Europe), 2000 ms (UK)
 
Multiplier  x 1
Current Settings:  10, 30, 100, 300, 500, 1000 mA
Current Accuracy:  +10% - 0%
RCD Type ¹:  G
Measurement Range:  310 ms
RCD Type ¹:  S
Measurement Range:  510 ms
 
Multiplier:  x 5
Current Settings:  10, 30 mA
Current Accuracy:  ±10%
RCD Type ¹:  G
Measurement Range:  50 ms
RCD Type ¹:  S
Tripping Current (ramp) Current Range:  50% - 110% of RCD's rated current
Step Size:  10% of IΔN
Dwell time (Type G): ¹  300 ms / step
Dwell time (Type S): ¹  500 ms / step
Trip Current Measurement Accuracy: ±5%
Earth Resistance Test (RE) - Fluke 1653B + 1654B  
Range/Resolution:  200 Ω/0.1 Ω
Accuracy:  ±(2% + 5 digits)
Range/Resolution:  2000 Ω/1 Ω
Accuracy:  ±(3.5% + 10 digits)
Frequency:  128 Hz
Compliance Voltage:  +25 V
Phase Sequence Indication Icon:  Icon Phase Sequence indicator is active
Display of Phase Sequence:  
 Displays ‘1-2-3’ in digital display field for correct sequence.
 Displays ‘3-2-1’ for incorrect phase.
 Dashes in place of a number indicate a valid determination could not be 
¹ RCD Types  G  General, no delay
S  Time delay
A  Responds to pulsed signal
AC  Responds to AC
B   1654B 
Environmental Specifications
Operating Temperature -10 °C to 40 °C
Humidity (Without Condensation) 10 to 30 °C:  95%
30 to 40 °C:  75%
Safety Specifications
Safety Rating EN 61010-I CAT III 500V, CAT IV 300V
Mechanical & General Specifications
Size  (L x W x H):  10 x 25 x 12.5 cm
Weight 1.3 kg
Batteries Type AA: 6
Warranty 3 years
Battery Type Alkaline supplied, usable with 1.2V NiCD or NiMH rechargeable batteries

Description

Fluke Zeroing Adapter for 1650 and 1660 Series Multifunction Testers

This Zero Adapter is designed for use with the Fluke 165xB and 166xB installation tester and allows easy compensation for test leads and mains cords.

This product is suitable for use with all mains plugs and can also be used in combination with test probes, alligator clips and other test equipment accessories.

For use with Fluke Multifunction Tester range 1651, 1652, 1653, 1654, 1662, 1663 and 1664. This adapter can be used for all different kind of mains plugs as well as test accessories like probes, alligator clips etc

ISSWWW and Fluke Instruments

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software.

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Fluke are a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. Our sales staff and our technicians are Fluke trained and we hold perhaps the largest stock of their products in the country. Our customers know that when it comes to Fluke products, we have not only the best prices but the best advice and support services, reassuring when you need to make that all important purchase.

Features & Specification

More Information
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description

Fluke 1650 Series

AC Voltage Measurement Range:  500 V
Resolution:  0.1 V
Accuracy (50 - 60 Hz)  ± (0.8% + 3 digits)
Input Impedance  3.3 MΩ
Overload Protection  660 Vrms
Continuity Testing Range (autoranging):  20 Ω, 200 Ω, 2000 Ω
Resolution:  0.01 Ω, 0.1 Ω, 1 Ω
Test Current:  > 200 mA
Open Circuit Voltage:  > 4 V
Accuracy:  ± (1.5%+3 digits)
Insulation Resistance Measurement Test Voltage:  
Fluke 1652C:  250 - 500 - 1000 V
Fluke 1653B + 1654B:  50 - 100 - 250 - 500 - 1000 V
 
   
Test Voltage:  50 V
Test Current:  1 mA @ 50 kΩ
Insulation Range:  10 kΩ - 50 мΩ
Resolution:  0.01 мΩ
Accuracy:  ± (3% + 3 digits)
   
Test Voltage:  100 V
Test Current:  1 mA @ 100 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  100 MΩ/0.1 MΩ
Accuracy:  ± (3% + 3 digits)
   
Test Voltage:  250 V
Test Current:  1 mA @ 250 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
   
Test Voltage:  500 V
Test Current:  1 mA @ 500 kΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
Range/Resolution:  500 MΩ/1 MΩ
Accuracy:  10%
   
Test Voltage:  1000 V
Test Current:  1 mA @ 1 MΩ
Range/Resolution:  20 MΩ/0.01 MΩ
Range/Resolution:  200 MΩ/0.1 MΩ
Accuracy:  ± (1.5% + 3 digits)
Range/Resolution:  500 MΩ/1 MΩ
Accuracy:  10%
   
Auto Discharge:  Discharge time constant, 0.5 second for C = 1 µF or less
Live Circuit Detection:  Inhibits test if terminal voltage > 30 V prior to initiation of test
Maximum Capacitive Load:  Operable with the 5 µF load
Loop Impedance Measurement (High Current Mode and Non-Trip Mode) Range:  100 - 500 VAC (50/60 Hz)
Input connection:  Soft Key selection
Loop impedance:  Phase to earth
Line impedance:  Phase to neutral
Limit on consecutive tests:  Automatic thermal shutdown after 50 consecutive tests at 10 second intervals (typical)
 
Max. Test Current High Current Mode:  
Non-Trip Mode:  
 
Range/Resolution (High Current):  20 Ω/0.001Ω (1mΩ) (Fluke 1654B)
Range/Resolution:  20 Ω/0.01 Ω
Range/Resolution:  200 Ω/0.1 Ω
Range/Resolution:  2000 Ω/1 Ω
 
Accuracy (no Trip mode):  ± (3% + 6 digits)
Accuracy (Hi Current mode):  ± (2% + 4 digits)
Accuracy (Hi Current mode 1mΩ):  ± (2% + 15 digits) (Fluke 1654B)
PFC, PSC Test
Computation:  PFC or PSC determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance
Range:  0 - 25 kA
Resolution (Ik < 1000 A):  1 A
Resolution (Ik >= 1000 A):  0.1 kA
Accuracy:  Determined by accuracy of loop resistance and mains voltage measurements.
RCD Testing ¹
Fluke 1654B:  A, AC, B, B+, F, G/R, S
Fluke 1652C:  A, AC, F, G/R, S
Fluke 1653B:  A, AC, F, G/R, S
Tripping Time Test (ΔT) Trip Time Accuracy  ±(1% Reading + 1 digit)
 
Multiplier:  x ½
Current Settings:  10, 30, 100, 300, 500, 1000 mA
Current Accuracy:  +0% - 10%
RCD Type ¹:  G
Measurement Range:  310 ms (Europe), 2000 ms (UK)
RCD Type ¹:  S
Measurement Range:  510 ms (Europe), 2000 ms (UK)
 
Multiplier  x 1
Current Settings:  10, 30, 100, 300, 500, 1000 mA
Current Accuracy:  +10% - 0%
RCD Type ¹:  G
Measurement Range:  310 ms
RCD Type ¹:  S
Measurement Range:  510 ms
 
Multiplier:  x 5
Current Settings:  10, 30 mA
Current Accuracy:  ±10%
RCD Type ¹:  G
Measurement Range:  50 ms
RCD Type ¹:  S
Tripping Current (ramp) Current Range:  50% - 110% of RCD's rated current
Step Size:  10% of IΔN
Dwell time (Type G): ¹  300 ms / step
Dwell time (Type S): ¹  500 ms / step
Trip Current Measurement Accuracy: ±5%
Earth Resistance Test (RE) - Fluke 1653B + 1654B  
Range/Resolution:  200 Ω/0.1 Ω
Accuracy:  ±(2% + 5 digits)
Range/Resolution:  2000 Ω/1 Ω
Accuracy:  ±(3.5% + 10 digits)
Frequency:  128 Hz
Compliance Voltage:  +25 V
Phase Sequence Indication Icon:  Icon Phase Sequence indicator is active
Display of Phase Sequence:  
 Displays ‘1-2-3’ in digital display field for correct sequence.
 Displays ‘3-2-1’ for incorrect phase.
 Dashes in place of a number indicate a valid determination could not be 
¹ RCD Types  G  General, no delay
S  Time delay
A  Responds to pulsed signal
AC  Responds to AC
B   1654B 
Environmental Specifications
Operating Temperature -10 °C to 40 °C
Humidity (Without Condensation) 10 to 30 °C:  95%
30 to 40 °C:  75%
Safety Specifications
Safety Rating EN 61010-I CAT III 500V, CAT IV 300V
Mechanical & General Specifications
Size  (L x W x H):  10 x 25 x 12.5 cm
Weight 1.3 kg
Batteries Type AA: 6
Warranty 3 years
Battery Type Alkaline supplied, usable with 1.2V NiCD or NiMH rechargeable batteries

Key Features Plug Adapter, Official Fluke Product, Fits A Range Of Devices, Test Accessories Like Probes And Croc Clips, Work With Fluke 1650 and 1660 Range

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA