Fluke T5-600-62 Max + 1AC

£275.94

Fluke T5-600 Voltage, Continuity and Current Tester

 

Specifications
Jaw opening 12.9 mm (0.5 in)
Max wire size 1/0 THHN Cable
Current range ac rms 0 to 100.0 A
Accuracy ac current (50/60 Hz) 3 % ± 3 counts
AC Response Averaging
Voltage range ac 0 to 600 V
Accuracy ac voltage 1.5 % ± 2 counts
Voltage range dc 0 to 600 V
Accuracy dc voltage 1 % ± 1 count
Resistance range 0 to 1000 Ω
Continuity beeper threshold On at <25 Ω, off at >400 Ω
Volts indicator LED threshold Guaranteed on by 30 V ac

 

Environmental Specifications
Operating Temperature -10 °C to 50 °C
Storage Temperature -30 °C to 60 °C
Humidity (Without Condensation) 0 % to 95 % (5 °C to 30 °C); 0 % to 75 % (30 °C to 40 °C);
0 % to 45 % (40 °C to 50 °C)
Dust/water resistance Yes
Operating Altitude 2000 meters max
Temperature Coefficient 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)

 

Safety Specifications
Overvoltage category CAT III 600 V ac/dc (EN61010-1)
Agency Approvals UL, CSA, and VDE
Maximum voltage Between any terminal and earth ground

 

Mechanical and General Specifications
Size 30.5 mm x 51 mm x 203 mm
Weight 300g
Warranty Two-years
Battery Life 200 hour zinc chloride, 400 hour alkaline
Battery type 2 x AA
Low battery indicator Yes
Current sensor opening 12.9 mm
Calibration cycle 1 year
Test leads Type: Heavy duty, flexible leads rated for 1000V use.
Field replaceable leads terminate in male shrouded banana plugs
Probes: One red, one black.
Detachable Slim-Reach™ probe tips
Styles: TP1 Slim Reach™ Test Probes

 

Safety Specifications
Safety CAT IV 600 V, CAT III, 1000 V
Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010

 

Fluke 62 MAX+ Infrared Thermometer

 

Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62 MAX+ <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability of Readings ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II

Description

This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem.

Fluke T5 Voltage, Continuity and Current Testers.

  • Automatically measures volts ac and volts dc with precise digital resolution.
  • Displays resistance to 1000Ω.
  • Easy and accurate OpenJaw™ current measurement.
  • Continuity beeper.
  • Rugged enough to withstand a 10-foot (3m) drop.
  • 600V model.
  • Auto off mode to conserve battery life.
  • AC current.
  • Display hold.
  • All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.

Fluke 62 MAX+. Small in size. Big on toughness.

  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.
  • C115 Deluxe Soft Carrying Case with Shoulder Strap.

Fluke 1AC Features:

  • Voltbeat™ technology and continuous self-test -- so you always know it's working
  • Upon detection, tip glows and beeper sounds
  • CAT IV 1000 V for added protection
  • Expanded range: 90 V to 1000 V AC or 200 V to 1000 V AC depending on model
  • 20 V to 90 V AC control circuit model also available

Features & Specification

More Information
Key Features LCD Display, GS38 Compliant, Detachable Probes, Current Test, Hold Function
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description

Fluke T5-600 Voltage, Continuity and Current Tester

 

Specifications
Jaw opening 12.9 mm (0.5 in)
Max wire size 1/0 THHN Cable
Current range ac rms 0 to 100.0 A
Accuracy ac current (50/60 Hz) 3 % ± 3 counts
AC Response Averaging
Voltage range ac 0 to 600 V
Accuracy ac voltage 1.5 % ± 2 counts
Voltage range dc 0 to 600 V
Accuracy dc voltage 1 % ± 1 count
Resistance range 0 to 1000 Ω
Continuity beeper threshold On at <25 Ω, off at >400 Ω
Volts indicator LED threshold Guaranteed on by 30 V ac

 

Environmental Specifications
Operating Temperature -10 °C to 50 °C
Storage Temperature -30 °C to 60 °C
Humidity (Without Condensation) 0 % to 95 % (5 °C to 30 °C); 0 % to 75 % (30 °C to 40 °C);
0 % to 45 % (40 °C to 50 °C)
Dust/water resistance Yes
Operating Altitude 2000 meters max
Temperature Coefficient 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)

 

Safety Specifications
Overvoltage category CAT III 600 V ac/dc (EN61010-1)
Agency Approvals UL, CSA, and VDE
Maximum voltage Between any terminal and earth ground

 

Mechanical and General Specifications
Size 30.5 mm x 51 mm x 203 mm
Weight 300g
Warranty Two-years
Battery Life 200 hour zinc chloride, 400 hour alkaline
Battery type 2 x AA
Low battery indicator Yes
Current sensor opening 12.9 mm
Calibration cycle 1 year
Test leads Type: Heavy duty, flexible leads rated for 1000V use.
Field replaceable leads terminate in male shrouded banana plugs
Probes: One red, one black.
Detachable Slim-Reach™ probe tips
Styles: TP1 Slim Reach™ Test Probes

 

Safety Specifications
Safety CAT IV 600 V, CAT III, 1000 V
Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010

 

Fluke 62 MAX+ Infrared Thermometer

 

Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62 MAX+ <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability of Readings ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA