Fluke T5-600-62 Max + 1AC
Fluke T5-600 Voltage, Continuity and Current Tester
Specifications | |
Jaw opening | 12.9 mm (0.5 in) |
Max wire size | 1/0 THHN Cable |
Current range ac rms | 0 to 100.0 A |
Accuracy ac current (50/60 Hz) | 3 % ± 3 counts |
AC Response | Averaging |
Voltage range ac | 0 to 600 V |
Accuracy ac voltage | 1.5 % ± 2 counts |
Voltage range dc | 0 to 600 V |
Accuracy dc voltage | 1 % ± 1 count |
Resistance range | 0 to 1000 Ω |
Continuity beeper threshold | On at <25 Ω, off at >400 Ω |
Volts indicator LED threshold | Guaranteed on by 30 V ac |
Environmental Specifications | |
Operating Temperature | -10 °C to 50 °C |
Storage Temperature | -30 °C to 60 °C |
Humidity (Without Condensation) | 0 % to 95 % (5 °C to 30 °C); 0 % to 75 % (30 °C to 40 °C); 0 % to 45 % (40 °C to 50 °C) |
Dust/water resistance | Yes |
Operating Altitude | 2000 meters max |
Temperature Coefficient | 0.1 x (specified accuracy)/°C (<18 °C or >28 °C) |
Safety Specifications | |
Overvoltage category | CAT III 600 V ac/dc (EN61010-1) |
Agency Approvals | UL, CSA, and VDE |
Maximum voltage | Between any terminal and earth ground |
Mechanical and General Specifications | ||
Size | 30.5 mm x 51 mm x 203 mm | |
Weight | 300g | |
Warranty | Two-years | |
Battery Life | 200 hour zinc chloride, 400 hour alkaline | |
Battery type | 2 x AA | |
Low battery indicator | Yes | |
Current sensor opening | 12.9 mm | |
Calibration cycle | 1 year | |
Test leads | Type: | Heavy duty, flexible leads rated for 1000V use. Field replaceable leads terminate in male shrouded banana plugs |
Probes: | One red, one black. Detachable Slim-Reach™ probe tips |
|
Styles: | TP1 Slim Reach™ Test Probes |
Safety Specifications | |
Safety | CAT IV 600 V, CAT III, 1000 V |
Maximum voltage | 1000 V AC rms from earth to ground, in compliance with EN61010 |
Fluke 62 MAX+ Infrared Thermometer
Specifications | ||
Temperature Range |
-30 °C to 650 °C (-22 °F to 1202 °F) | |
Accuracy | ±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 |
|
Response Time (95%) | Fluke 62 MAX+ | <300 ms (95% of reading) |
Spectral Response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical Resolution |
12:1 (calculated at 90% energy) | |
Display Resolution | 0.1 °C (0.2 °F) | |
Repeatability of Readings | ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater | |
Power | AA battery | |
Battery Life | 8 hours with laser and backlight on | |
Physical Specifications | Weight | 255 g (8.99 oz) |
Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches | |
Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) | |
Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F), (without battery) | |
Operating Humidity | 10 % to 90 % RH non-condensing at 30 °C (86 °F) | |
Operating Altitude | 2000 meters above mean sea level | |
Storage Altitude | 12,000 meters above mean sea level | |
IP Rating | IP 54 per IEC 60529 | |
Drop Test | 3 meters | |
Vibration and Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 | |
Standards and Agency Approval |
Compliance | EN/IEC 61010-1: 2001 |
Laser Safety | FDA and EN 60825-1 Class II |
Description
This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem.
Fluke T5 Voltage, Continuity and Current Testers.
- Automatically measures volts ac and volts dc with precise digital resolution.
- Displays resistance to 1000Ω.
- Easy and accurate OpenJaw™ current measurement.
- Continuity beeper.
- Rugged enough to withstand a 10-foot (3m) drop.
- 600V model.
- Auto off mode to conserve battery life.
- AC current.
- Display hold.
- All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.
Fluke 62 MAX+. Small in size. Big on toughness.
- Dust and water-resistant: IP54 rated.
- Rugged: 3-meter (9.8-foot) drop tested.
- Ergonomically designed: Completely redesigned for a more natural hand fit.
- Distance to spot: 12:1.
- Dual lasers: Identifies area to be measured.
- Large, backlit display: Makes data easier to read, even in dark areas.
- C115 Deluxe Soft Carrying Case with Shoulder Strap.
Fluke 1AC Features:
- Voltbeat™ technology and continuous self-test -- so you always know it's working
- Upon detection, tip glows and beeper sounds
- CAT IV 1000 V for added protection
- Expanded range: 90 V to 1000 V AC or 200 V to 1000 V AC depending on model
- 20 V to 90 V AC control circuit model also available
Features & Specification
Key Features | LCD Display, GS38 Compliant, Detachable Probes, Current Test, Hold Function | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Fluke Testers | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description | Fluke T5-600 Voltage, Continuity and Current Tester
Fluke 62 MAX+ Infrared Thermometer
|
Delivery
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA