Fluke SMFT1000/PRO Technical Specifications

Protective conductor resistance (RLO)

Display range

Measuring range

Resolution

Accuracy

0.00 Ω - 19.99 Ω

0.20 Ω - 19.99 Ω

0.01 Ω

± (2 % + 2 Digit)

20.0 Ω- 199.9 Ω

20.0 Ω - 199.9 Ω

0.1 Ω

± (2 % + 2 Digit)

200 Ω - 2000 Ω

200 Ω - 2000 Ω

1 Ω

± (5 % + 2 Digit)

       

Test current

≥ 200 mA (≤ 2Ω + Rcomp)

   

Test voltage

4 V DC … 10 V DC

   

Polarity reversing

Yes

   

Test lead zero (Rcomp)

Up to 3 Ω

   
       

PV module/PV string, open-circuit voltage (Voc)

Display range

Measuring range

Resolution

Accuracy

0.0 V - 99.9 V

5.0 V - 99.9 V

0.1 V

± (0.5 % + 2 Digit)

100 V - 1000 V

100 V - 1000 V

1 V

       

Polarity test

Yes

   
       

PV module/PV string, short-circuit current (Is/c)

Display range

Measuring range

Resolution

Accuracy

0.0 A - 20.0 A

0.2 A - 20.0 A

0.1 A

± (1 % + 2 Digit)

       

Insulation resistance (RINS)

Display range

Measuring range

Resolution

Accuracy

0.00 MΩ - 99.99 MΩ

0.20 MΩ - 99.99 MΩ

0.01 MΩ

± (5 % + 5 Digit)

100.0 MΩ - 199.9 MΩ

100.0 MΩ - 199.9 MΩ

0.1 MΩ

± (10 % + 5 Digit)

200 MΩ - 999 MΩ

200 MΩ - 999 MΩ

1 MΩ

± (20 % + 5 Digit)

       

 

Measuring range

Resolution

Accuracy

Test voltage @ no load

50 V / 100 V / 250 V up to 199.9 MΩ
500 V / 1000 V up to 999 MΩ

1 V

0 % to + 20 %

Test voltage @ ≥ 1 mA

250 V @ 250 kΩ
500 V @ 500 kΩ
1000 V @ 1 MΩ

1 V

0 % to + 10 %

Testing current

Min. 1 mA (@ 250 kΩ / 500 kΩ / 1 MΩ)
Max. 1.5 mA (short circuit)

 

 

 

 

     

Blocking diode checking (Vbd)

Display range

Measuring range

Resolution

Accuracy

0.00 V DC - 6.00 V DC

0.50 V DC - 6.00 V DC

0.01 V DC

± (5 %  + 10 Digit)

       

Overvoltage protective devices (BV)

Display range

Measuring range

Resolution

Accuracy

0 V DC - 1000 V DC

50 V DC - 1000 V DC

1 V DC

± (10 % + 5 Digit)

       

AC/DC voltage measurement via 4 mm test sockets

Display range

Measuring range

Resolution

Accuracy

0.0 V AC - 99.9 V AC

5.0 V AC - 99.9 V AC

0.1 V

± (2.5 % + 2 Digit)

100 V AC - 700 V AC

100 V AC - 700 V AC

1 V

0.0 V DC - 99.9 V DC

5.0 V DC - 99.9 V DC

0.1 V

100 V DC - 1000 V DC

100 V DC - 1000 V DC

1 V

       

Detection AC/DC

Yes (Automatic)

   

+ / - polarity check

Yes

   
       

AC/DC current with i100 clamp adapter

Display range

Measuring range

Resolution

Accuracy (DC, AC 50 Hz/60 Hz)

0.0 A DC – 100 A DC

1.0 A DC – 100 A DC

0.1 A

± (5 % + 2 Digit), i100 clamp tolerances not inclusive

0.0 A AC – 100 A AC TRMS

1.0 A AC – 100 A AC TRMS

       

I100 Clamp adapter Tolerances

Display range

Measuring range

Output signal

Accuracy (DC, AC 50 Hz/60 Hz)

N/A

1 A - 100 A DC or AC < 1 kHz

10 mV/A AC/DC

± (1.5 % + 0.1 A)

       

AC/DC Power measurement (with i100 clamp adapter)

Display range

Measuring range

Resolution

Accuracy (DC, AC 50 Hz/60 Hz)

0.0 V AC - 700 V AC
0.0 V DC - 1000 V DC

5.0 V AC - 700 V AC
5.0 V DC - 1000 V DC

0.1 V

± (2.5 % + 2 Digit)

0 A AC/DC - 100 A AC/DC

1 A AC/DC- 100 A AC/DC

0.1 A

± (6.5 % + 3 Digit)

0 kW/kVA – 100 kW/kVA

5 kW/kVA – 100 kW/kVA

1 kW/kVA

± (10 % + 4 Digit)

 

General Specifications

SMFT-1000 size

10 cm x 25.0 cm x 12.5 cm (3.8 in x 9.8 in x 4.9 in)

SMFT-1000 weight

1.4 kg (3.09 lb)

Battery

6 AA IEC LR6

Operating temperature

0 °C to 50 °C (32 °F to 122 °F)

Storage temperature

-30 °C to 60 °C (-22 °F to 140 °F) batteries removed

Operating altitude

up to 2000 m

Storage altitude

up to 2000 m

Safety

SMFT-1000 PV Analyzer

IEC 61010-1 Pollution Degree 2
IEC 61010-2-034 CAT III 1000 V DC, CAT III 700 V AC

i100 Current Clamp Adapter

IEC 61010-2-032, Type D (for insulated conductors), 1000 V

Accessories

IEC 61010-031

TL1000-MC4

CAT III 1500 V, 20 A

TP1000 Remote Probe (with cap)

CAT IV 600 V, CAT III 1000 V, 10 A

TP1000 Remote Probe (without cap)

CAT II 1000 V, 10 A

TL1000 Test Leads

CAT III 1000 V, 10 A

TL1000/30M Test Leads

CAT III 1000 V, CAT IV 600 V, 5 A (on reel) 10 A (fully extended)

TP74 Test Probes (with cap)

CAT III 1000 V, 10 A

TP74 Test Probes (without cap)

CAT II 1000 V, 10 A

AC285 Alligator Clip

CAT III 1000 V, 10 A

Performance

IEC 61557-1, IEC 61557-2, IEC 61557-4, IEC 61557-10

   

Electromagnetic Compatibility (EMC)

International

IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency
energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other
environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide
adequate protection to radio reception in such environments.

   

Wireless Radio Module

Frequency Range

2.402 GHz to 2.480 GHz

Output Power

8 dBm

Description

Fluke SMFT-1000/KIT Multifunction PV Analyzer 5280005

All-in-one test solution to verify PV system performance and safety, expedite client reporting

Test that PV systems are performing to their optimal power output as well as operating safely with the Fluke SMFT-1000 multifunction tester with I-V curve traci
ng (Figure 1).  Designed for PV professionals that provide installation, commissioning and maintenance services to systems that operate at 1000 V DC or under, the SMFT-1000 provides a complete PV testing solution that conforms to IEC/EN 62446-1 standards. Through Fluke’s TruTest™ Software, measurement data from solar site installation and commissioning testing can be easily imported, organized, and analyzed for effortless reporting without having to bring a laptop on-site.

Fluke SMFT-1000 KIT Contents:

  • Fluke SMFT-1000-BP Professional Tool Backpack
  • SMFT-1000 Multifunction PV Analyzer
  • Carry strap
  • Fuse pack
  • Adapter Cable IRDA Optical-to-USB
  • Zero adapter
  • IRR2-BT Wireless Solar Irradiance Meter Pro
  • 80PR-IRR External Temperature Probe
  • Mounting Bracket for solar module
  • Carry Case
  • i100 AC/DC Current Clamp 100 A
  • TPAK Magnet Set
  • TP1000 Test Probe with Remote Test Button
  • TL1000 Test Lead Set
  • TL1000-MC4 Test Lead Set
  • TL1000/30M Test Lead on Reel
  • Coupler set
  • (6) AA Batteries

 


 

Features and Functions:

Critical testing features for initial and periodic inspection of PV systems

  • Full sequence safety testing – IEC/EN 62446-1 Category 1:
    • Protective conductor resistance (RLO)
    • Voltage on open circuit, including polarity (VOC)
    • Short circuit current (ISC) or operational current with clamp adapter
    • Insulation resistance (RINS)
  • ROI and system performance testing (solar module string I-V curve test) – IEC 62446-1 Category 2:
    • Solar PV I-V curve tracing and associated software for analysis, reporting and certification and includes I-V curve analysis and reporting features
    • Computer software - download, upload, review, analyze and print test results
    • Communication with IRR2-BT (solar irradiation, inclination, temperature)
    • Communication with computer
  • Visual inspection
  • Protective conductor resistance (RLO) measurement with a testing current ≥200 mA
  • Polarity check with automatic display of the voltage polarity with acoustic/visual warning for wrong polarity
  • Open-circuit voltage (VOC) measurement at the PV module/string with up to 1000 V DC
  • Short-circuit (ISC) current measurement at the PV module/string with up to 20 A DC or operational current with clamp adapter up to 100 A DC
  • Insulating resistance (RINS) measurement with a testing voltage of 50 V, 100 V, 250 V, 500 V and 1000 V
  • Blocking diode measurement (VBD)
  • Surge protection device testing
  • AC/DC voltage measurement with 4 mm test sockets - Functional test by means of voltage measurement up to 700 V TRMS (for sinusoidal voltage up to 60 Hz) and 1000 V DC. The AC voltage and AC current measurement refers to frequency 50 Hz or 60 Hz, sinusoidal voltage.
  • AC/DC current measurement - functional test by means of current measurement with a current clamp adapter up to 100 A AC/DC
  • Bypass diode measurement of module when covered or in darkness

Recommended tools for use with the SMFT-1000:

  • 393 FC CAT III 1500 V Solar Clamp Meter
  • 87V MAX True-rms Digital Multimeter
  • 1587 FC Insulation Multimeter
  • Ti480 PRO Infrared Camera
  • 1625-2 GEO Earth Ground Tester
  • 500 Series Battery Analyzers
  • Pomona PVLEAD3 MC4 Solar Clamp Test Lead Set


TruTest™ Solar Data Management Software (Not Included):

Spend less time processing test results and compiling reports.
The reporting necessary to close out projects can be challenging and time-consuming.
Cover all your certification and documentation needs through the modern, fast and
reliable software platform of TruTest™. TruTest™ allows for solar asset management,
data storage and reporting on a single platform. Whether you are analyzing panel
efficiency through I-V curves, or safety testing the system through the Category 1
test regime in conformance to IEC 62446-1, proper data management is critical for
producing easy-to-understand reports for clients.

Compatible with the Fluke SMFT1000 Multifunction PV Tester and Performance Analyzer, TruTest™ software allows you to quickly and easily import measurement results directly from your solar multifunction tester to computer, organize and analyze the data, compare individual asset data against previous measurements imported and provide a comprehensive and visual client report.


• Easily manage measurement data from solar site installation and commissioning testing
• Quickly create inspections and reports compliant with IEC 62446-1 and other directives
• I-V curve analysis with easy pass/fail visuals; see changes in I-V curve over multiple site visits
• Easily manage measurement data from solar site installation and commissioning testing
• Compare site data to previous site data to see changes over time
• A free 60-day demo version of TruTest™ is available for download on fluke.com. Purchase a software key to unlock the Lite or Advanced version.






Function Demo Lite Advanced
Maximum addable clients 1 10 Unlimited
Maximum addable site/client 2 5 Unlimited
Maximum addable strings 5 50 Unlimited
Maximum addable modules (per string) 50 50 Unlimited
Edit distribution board information No Yes Yes
Edit circuit information No Yes Yes
Edit inverter information No Yes Yes
Edit combiner box information No Yes Yes
Edit string information No Yes Yes
Edit module information No Yes Yes

 

isswww and Fluke Instruments 

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software. 

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products. 

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, meteorologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities. 

Fluke are a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. Our sales staff and our technicians are Fluke trained and we hold perhaps the largest stock of their products in the country. Our customers know that when it comes to Fluke products, we have not only the best prices but the best advice and support services, reassuring when you need to make that all-important purchase.  

 

Features & Specification

More Information
Key Features IEC 62446-1 Category 1&2 Testing, Protective resistance earth RLO, Voltage on open circuit including polarity VOC, Short circuit current ISC, Insulation resistance RINS, I-V Curve tracing and software analysis with TruTest™, Irradiance temperature tilt cardinal direction
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description

Fluke SMFT1000/PRO Technical Specifications

Protective conductor resistance (RLO)

Display range

Measuring range

Resolution

Accuracy

0.00 Ω - 19.99 Ω

0.20 Ω - 19.99 Ω

0.01 Ω

± (2 % + 2 Digit)

20.0 Ω- 199.9 Ω

20.0 Ω - 199.9 Ω

0.1 Ω

± (2 % + 2 Digit)

200 Ω - 2000 Ω

200 Ω - 2000 Ω

1 Ω

± (5 % + 2 Digit)

       

Test current

≥ 200 mA (≤ 2Ω + Rcomp)

   

Test voltage

4 V DC … 10 V DC

   

Polarity reversing

Yes

   

Test lead zero (Rcomp)

Up to 3 Ω

   
       

PV module/PV string, open-circuit voltage (Voc)

Display range

Measuring range

Resolution

Accuracy

0.0 V - 99.9 V

5.0 V - 99.9 V

0.1 V

± (0.5 % + 2 Digit)

100 V - 1000 V

100 V - 1000 V

1 V

       

Polarity test

Yes

   
       

PV module/PV string, short-circuit current (Is/c)

Display range

Measuring range

Resolution

Accuracy

0.0 A - 20.0 A

0.2 A - 20.0 A

0.1 A

± (1 % + 2 Digit)

       

Insulation resistance (RINS)

Display range

Measuring range

Resolution

Accuracy

0.00 MΩ - 99.99 MΩ

0.20 MΩ - 99.99 MΩ

0.01 MΩ

± (5 % + 5 Digit)

100.0 MΩ - 199.9 MΩ

100.0 MΩ - 199.9 MΩ

0.1 MΩ

± (10 % + 5 Digit)

200 MΩ - 999 MΩ

200 MΩ - 999 MΩ

1 MΩ

± (20 % + 5 Digit)

       

 

Measuring range

Resolution

Accuracy

Test voltage @ no load

50 V / 100 V / 250 V up to 199.9 MΩ
500 V / 1000 V up to 999 MΩ

1 V

0 % to + 20 %

Test voltage @ ≥ 1 mA

250 V @ 250 kΩ
500 V @ 500 kΩ
1000 V @ 1 MΩ

1 V

0 % to + 10 %

Testing current

Min. 1 mA (@ 250 kΩ / 500 kΩ / 1 MΩ)
Max. 1.5 mA (short circuit)

 

 

 

 

     

Blocking diode checking (Vbd)

Display range

Measuring range

Resolution

Accuracy

0.00 V DC - 6.00 V DC

0.50 V DC - 6.00 V DC

0.01 V DC

± (5 %  + 10 Digit)

       

Overvoltage protective devices (BV)

Display range

Measuring range

Resolution

Accuracy

0 V DC - 1000 V DC

50 V DC - 1000 V DC

1 V DC

± (10 % + 5 Digit)

       

AC/DC voltage measurement via 4 mm test sockets

Display range

Measuring range

Resolution

Accuracy

0.0 V AC - 99.9 V AC

5.0 V AC - 99.9 V AC

0.1 V

± (2.5 % + 2 Digit)

100 V AC - 700 V AC

100 V AC - 700 V AC

1 V

0.0 V DC - 99.9 V DC

5.0 V DC - 99.9 V DC

0.1 V

100 V DC - 1000 V DC

100 V DC - 1000 V DC

1 V

       

Detection AC/DC

Yes (Automatic)

   

+ / - polarity check

Yes

   
       

AC/DC current with i100 clamp adapter

Display range

Measuring range

Resolution

Accuracy (DC, AC 50 Hz/60 Hz)

0.0 A DC – 100 A DC

1.0 A DC – 100 A DC

0.1 A

± (5 % + 2 Digit), i100 clamp tolerances not inclusive

0.0 A AC – 100 A AC TRMS

1.0 A AC – 100 A AC TRMS

       

I100 Clamp adapter Tolerances

Display range

Measuring range

Output signal

Accuracy (DC, AC 50 Hz/60 Hz)

N/A

1 A - 100 A DC or AC < 1 kHz

10 mV/A AC/DC

± (1.5 % + 0.1 A)

       

AC/DC Power measurement (with i100 clamp adapter)

Display range

Measuring range

Resolution

Accuracy (DC, AC 50 Hz/60 Hz)

0.0 V AC - 700 V AC
0.0 V DC - 1000 V DC

5.0 V AC - 700 V AC
5.0 V DC - 1000 V DC

0.1 V

± (2.5 % + 2 Digit)

0 A AC/DC - 100 A AC/DC

1 A AC/DC- 100 A AC/DC

0.1 A

± (6.5 % + 3 Digit)

0 kW/kVA – 100 kW/kVA

5 kW/kVA – 100 kW/kVA

1 kW/kVA

± (10 % + 4 Digit)

 

General Specifications

SMFT-1000 size

10 cm x 25.0 cm x 12.5 cm (3.8 in x 9.8 in x 4.9 in)

SMFT-1000 weight

1.4 kg (3.09 lb)

Battery

6 AA IEC LR6

Operating temperature

0 °C to 50 °C (32 °F to 122 °F)

Storage temperature

-30 °C to 60 °C (-22 °F to 140 °F) batteries removed

Operating altitude

up to 2000 m

Storage altitude

up to 2000 m

Safety

SMFT-1000 PV Analyzer

IEC 61010-1 Pollution Degree 2
IEC 61010-2-034 CAT III 1000 V DC, CAT III 700 V AC

i100 Current Clamp Adapter

IEC 61010-2-032, Type D (for insulated conductors), 1000 V

Accessories

IEC 61010-031

TL1000-MC4

CAT III 1500 V, 20 A

TP1000 Remote Probe (with cap)

CAT IV 600 V, CAT III 1000 V, 10 A

TP1000 Remote Probe (without cap)

CAT II 1000 V, 10 A

TL1000 Test Leads

CAT III 1000 V, 10 A

TL1000/30M Test Leads

CAT III 1000 V, CAT IV 600 V, 5 A (on reel) 10 A (fully extended)

TP74 Test Probes (with cap)

CAT III 1000 V, 10 A

TP74 Test Probes (without cap)

CAT II 1000 V, 10 A

AC285 Alligator Clip

CAT III 1000 V, 10 A

Performance

IEC 61557-1, IEC 61557-2, IEC 61557-4, IEC 61557-10

   

Electromagnetic Compatibility (EMC)

International

IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency
energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other
environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide
adequate protection to radio reception in such environments.

   

Wireless Radio Module

Frequency Range

2.402 GHz to 2.480 GHz

Output Power

8 dBm

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA