FLUKE PVA-1500T2 Solmetric PV Analyzer IV Curve Tracer 5600022

£12,024.00

Specifications: PVA-1500 Series PV Analyzer, I-V Curve Tracer

 
 
PVA-1500 Specifications    
  PVA-1500T2 PVA-1500HE2
Voltage Range (Voc) 20 to 1500V DC
Maximum Current Range (Isc)
Module Efficiency <19% 0 to 30A DC
Module Efficiency ≥19% 0 to 10A DC 0 to 30A DC
Voltage Accuracy (0 °C to 45 °C) ±(0.5% ±0.25V)
Current Accuracy (0 °C to 45 °C) ±(0.5% ±0.04A)
Power Accuracy (0 °C to 45 °C) ±(1.7 % + 1.0 W) (current ≥3 A, module efficiency <19 %)
Voltage Resolution 25 mV
Current Resolution 2 mA
Measurement Throughput
Sweep-to-sweep delay (@VOC ≤ 1350V) <9 seconds
Max number of I-V sweeps per hour (@VOC ≤ 1350V) 400 sweeps/hr
Max megawatts measured per hour 3.5 MW/hr
Thermal Capacity
# sweeps at 18 s sweep-to-sweep delay unlimited (25 °C, 77 °F ambient)
550 (45 °C, 113 °F ambient)
# sweeps at 9s sweep-to-sweep delay unlimited (25 °C, 77 °F ambient)
330 (45 °C, 113 °F ambient)
I-V Trace Points 100 or 500 (selectable)
I-V Sweep Duration 0.05 to 2 seconds (typically 0.2 seconds for PV strings)
Operating Temperature Range 0 °C to 45 °C, 32 °F to 113 °F
Storage Temperature Range -20 °C to 65 °C, -4 °F to 149 °F
Operating Humidity <90 % RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used.
Altitude 2000 m max
Battery Charging Time 6 hr
Battery Run Time Approx. 8 hr Approx. 7 hr
Safety and Regulatory CAT III 1500V
IEC 61010-1: Pollution Degree 2
Warning Features Over-voltage, over-current, over-temperature, reverse
polarity
PV Connector Staubli MC4-EVO2 Banana Jacks
Charging/Charged LED Yes
In-the-field firmware update-ready Yes
Interface to Tablet/Laptop Wi-Fi interface between user tablet or laptop, I-V unit and
SolSensor™
Weight 6.6 kg, 14.55 lb 7.3 kg, 16.09 lb
Height 43.2 cm, 1.41 ft (including test lead and strain reliefs) 53.3 cm, 1.74 ft
Width 21.6 cm, 8.50 in
Depth 15.2 cm, 5.98 in

PVA-1500 Test Lead and Clip Specifications
Voltage Range 0 to 1500V DC
Current Range 0 to 30A DC
Temperature 0 °C to 45 °C, 32 °F to 113 °F
Humidity Maximum relative humidity of 80% for temperatures up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F)
Pollution Degree 2
Altitude 2000 m, 6561 ft maximum
Lead Length 152 cm, 59.84 in
Lead Colors Positive=red, negative=black
Manufacturer (Test Leads and Alligator Clips) Staubli
Note: Use only test leads and clips provided by Fluke for the PVA-1500.
   
SolSensor™ Specifications  
Irradiance 
Sensor Type Silicon photodiode with corrections for temperature, spectral, and angular effects
Measurement Range 100 W/m² to 1500 W/m²
Accuracy ±2 % when used to predict the performance of well characterized poly- and monocrystalline PV modules with direct irradiance >600W/m²
Resolution 1 W/m²
Measurement Interval Typically, 3.5 s
Temperature
Sensor Type Type K thermocouple, two inputs
Measurement Range 0 °C to 100 °C, 32 °F to 212 °F
Accuracy ±2 °C, 35.6 °F (not including limits of error of thermocouple)
Resolution 0.1 °C, 32.18 °F
Measurement Interval Typically, 3.5 s
Tilt
Sensor Type Electronic
Measurement Range 0 to 90° from horizontal
Accuracy ±2° typical (0 to 45°)
General
Measurement Cynchronization with I-V Curve Typically, <1 s
Wireless Range (open line of sight) 100 m, 328 ft 
Operating Temperature Range 0 ºC to 45 ºC, 32 ºF to 113 ºF
Storage Temperature Range -20 ºC to 65 ºC, -4 ºF to 149 ºF
Operating Humidity <90% RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used.
Battery Charging Time 6 hr
Battery Run Time >16 hr typical use
NEW

Description

FLUKE-PVA-1500T2 Solmetric PV Analyzer IV Curve Tracer 5600022

Measure your solar PV system performance

The PVA-1500 is a cutting-edge I-V curve tracer kit designed to measure PV system performance. With this high precision testing equipment, you can reliably assess the health and performance of solar modules and arrays, making informed decisions to enhance their output and longevity.

The PVA-1500 kit offers an array of advanced features, including high throughput I-V curve tracing, providing quick and detailed performance data. Its intuitive user interface enables easy navigation and real-time analysis, allowing for immediate identification of potential issues. By pinpointing problems early, you can maximize your solar energy production and minimize downtime.

Fluke PVA-1500T2 Comes Supplied With:

  • PVA-1500 V unit
  • SolSensor™ and clamp
  • Alligator test leads
  • MC4 disconnect tool
  • Chargers
  • 2x thermocouples and adhesive disks
  • Sensor cleaning supplies
  • Available by free download: PVA Application and Data Analysis Tool

 

Key Features:

  • Measures and displays I-V curves up to 1500V and 30A, including on high efficiency modules (PVA-1500HE2)
  • Advanced built-in PV model provides immediate PV performance checking
  • Sweep-to-sweep delay of 9 seconds to measure 3.5MW in <1hr
  • Wireless interfaces for faster setup, safer work environment, and freedom of movement during PV troubleshooting
  • Automates data management, analysis, and reporting

Comprehensive measurements and efficient analysis

For commissioning, operations, maintenance, and troubleshooting of PV arrays, I-V curve testing is the most complete solar module performance measurement. Quick analysis of curve datasets aids in detecting outliers, and the stored data functions as a baseline for future performance inquiries.

Accurate I-V curve tracing

The PVA measures the I-V (current versus voltage) curve of a PV string or module using a capacitive load. The measurement is typically performed at the string level by connecting directly to the string or at a combiner box using the fuses to select the string under test. The number of I-V curve points can be selected at 100 or 500. Additionally, the PVA generates the P-V (power versus voltage) curve, Isc, Voc, Imp, Vmp, Pmax, fill factor, and performance factor (the ratio of measured to expected maximum power).

Time-saving interface

With a tablet or laptop (Windows only) as the user interface, perform more tests per hour and display the data in multiple, easy to read formats. Save your measurements by touching your customized array tree at the branch you are measuring. The software automatically calculates the expected I-V curve and displays the performance factor.

Advanced High Efficiency PV Testing Capabilities

Accurate measurement of high efficiency modules up to 30A: Highly efficient modules (>19% module efficiency) possess high capacitance, posing a challenge for some I-V curve tracers that may not be able to measure them. The PVA-1500HE2 is uniquely designed to measure all string types, even those with high efficiency modules, up to 30A. Rapid performance in high temperature environments: The PVA-1500HE2 operates with a swift sweep-to-sweep delay of 9 seconds (at Voc < 1350V). This results in the ability to measure 3.5 MW within an hour, even in high-temperature settings where standard curve tracers often fail due to overheating.

SolSensor™ Wireless PV Reference Sensor

The SolSensor™ provides irradiance, module temperature, and array tilt data to the PV model. The model uses this information to predict the I-V curve shape at these operating conditions and to translate the measured curve to standard test conditions. The SolSensor™ clamps to the module frame, automatically orienting the irradiance sensor to the plane-of-array.

The spectral response of the silicon photodiode sensor in the SolSensor™ is corrected for the PV technology under test. Special factors are provided for multi- and mono-crystalline cells as well as cadmium telluride (CdTe) and other thin film technologies. The sensor is temperature compensated and the angular response of each unit is calibrated for rotation and elevation. As a result, the SolSensor™ is accurate over a broad range of technologies, sky conditions, and sun angles, allowing I-V curve measurements earlier and later in the day.

The SolSensor™ provides two external thermocouple inputs for measuring module backside temperatures. Effective cell temperature can also be calculated directly from the measured I-V curve per IEC 60904-5. The PVA’s SmartTemp™ feature, optionally, blends these two methods for best accuracy.

The PVA and SolSensor™ communicate wirelessly with your PC via WiFi with a line-of-sight wireless range of 100m. That means no wires underfoot, quick setup, the ability to move around while troubleshooting strings, and flexibility to measure multiple combiner boxes with a single SolSensor™ setup.

Turn PVA data into key insights, visualizations, and customizable reports

Capture data in the field with the PVA Application and validate the results with the Data Analysis Tool (DAT), a Microsoft Excel™-based solution streamlining the analysis of PVA I-V curve data. It presents analysis results in multiple formats. It compiles key PV parameters in a string table, flags non-conforming strings, and delivers a statistical overview of the entire array. Additionally, it visually combines string I-V curves at the combiner box level, offering a clear depiction of consistency and identifying atypical strings. The tool also generates histograms for PV parameters across the string population, and this data can be added to a customizable report exported as a PDF. The Data Analysis Tool (DAT) can be downloaded for free use with any PVA. Supported languages: English, French, Spanish, German, Italian, Traditional Chinese, Simplified Chinese, and Brazilian Portuguese.

Download the PVA Application and Data Analysis Tool

Kit Options:

What’s Included?

Kit Option

Standard

560002

High-Efficiency

5600010

Thermography Kit

 

Clamp & Multimeter Kit Insulation, Clamp, & Multimeter Kit Insulation Testing Kit
Fluke PVA-1500T2           
Fluke PVA-1500HE2  
Fluke TiS75+ Thermal Imager          
Fluke 393 FC Clamp Meter        
Fluke 87V TRMS Multimeter        
Fluke 1587 FC Insulation Tester & Multimeter          
Fluke 1537 Insulation Resistance Tester & Megohmmeter          
Alligator Test Leads
MC4 Disconnector Tool
Chargers
2x Thermocouples & Adhesive Discs
Sensor Cleaning Supplies
PVA Application for Windows 
Data Analysis Tool

Also Available:

isswww and Fluke Instruments

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software.  

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.  

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, meteorologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.  

Fluke are a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. We have Fluke trained staff on site and we hold an extensive range of their products. Our customers know that when it comes to Fluke products, we have great prices and exceptional advice and support services, reassuring when you need to make that all-important purchase. 

Features & Specification

More Information
Key Features Cutting-edge PV measurement technology, Measures I-V curves up to 1500V and 30A, Immediate PV performance checking, Sweep-to-sweep delay 9 sec - 3.5MW in 70000 module database with automatic updates
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description

Specifications: PVA-1500 Series PV Analyzer, I-V Curve Tracer

 
 
PVA-1500 Specifications    
  PVA-1500T2 PVA-1500HE2
Voltage Range (Voc) 20 to 1500V DC
Maximum Current Range (Isc)
Module Efficiency <19% 0 to 30A DC
Module Efficiency ≥19% 0 to 10A DC 0 to 30A DC
Voltage Accuracy (0 °C to 45 °C) ±(0.5% ±0.25V)
Current Accuracy (0 °C to 45 °C) ±(0.5% ±0.04A)
Power Accuracy (0 °C to 45 °C) ±(1.7 % + 1.0 W) (current ≥3 A, module efficiency <19 %)
Voltage Resolution 25 mV
Current Resolution 2 mA
Measurement Throughput
Sweep-to-sweep delay (@VOC ≤ 1350V) <9 seconds
Max number of I-V sweeps per hour (@VOC ≤ 1350V) 400 sweeps/hr
Max megawatts measured per hour 3.5 MW/hr
Thermal Capacity
# sweeps at 18 s sweep-to-sweep delay unlimited (25 °C, 77 °F ambient)
550 (45 °C, 113 °F ambient)
# sweeps at 9s sweep-to-sweep delay unlimited (25 °C, 77 °F ambient)
330 (45 °C, 113 °F ambient)
I-V Trace Points 100 or 500 (selectable)
I-V Sweep Duration 0.05 to 2 seconds (typically 0.2 seconds for PV strings)
Operating Temperature Range 0 °C to 45 °C, 32 °F to 113 °F
Storage Temperature Range -20 °C to 65 °C, -4 °F to 149 °F
Operating Humidity <90 % RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used.
Altitude 2000 m max
Battery Charging Time 6 hr
Battery Run Time Approx. 8 hr Approx. 7 hr
Safety and Regulatory CAT III 1500V
IEC 61010-1: Pollution Degree 2
Warning Features Over-voltage, over-current, over-temperature, reverse
polarity
PV Connector Staubli MC4-EVO2 Banana Jacks
Charging/Charged LED Yes
In-the-field firmware update-ready Yes
Interface to Tablet/Laptop Wi-Fi interface between user tablet or laptop, I-V unit and
SolSensor™
Weight 6.6 kg, 14.55 lb 7.3 kg, 16.09 lb
Height 43.2 cm, 1.41 ft (including test lead and strain reliefs) 53.3 cm, 1.74 ft
Width 21.6 cm, 8.50 in
Depth 15.2 cm, 5.98 in

PVA-1500 Test Lead and Clip Specifications
Voltage Range 0 to 1500V DC
Current Range 0 to 30A DC
Temperature 0 °C to 45 °C, 32 °F to 113 °F
Humidity Maximum relative humidity of 80% for temperatures up to 31 °C (87.8 °F) decreasing linearly to 50% relative humidity at 40 °C (104 °F)
Pollution Degree 2
Altitude 2000 m, 6561 ft maximum
Lead Length 152 cm, 59.84 in
Lead Colors Positive=red, negative=black
Manufacturer (Test Leads and Alligator Clips) Staubli
Note: Use only test leads and clips provided by Fluke for the PVA-1500.
   
SolSensor™ Specifications  
Irradiance 
Sensor Type Silicon photodiode with corrections for temperature, spectral, and angular effects
Measurement Range 100 W/m² to 1500 W/m²
Accuracy ±2 % when used to predict the performance of well characterized poly- and monocrystalline PV modules with direct irradiance >600W/m²
Resolution 1 W/m²
Measurement Interval Typically, 3.5 s
Temperature
Sensor Type Type K thermocouple, two inputs
Measurement Range 0 °C to 100 °C, 32 °F to 212 °F
Accuracy ±2 °C, 35.6 °F (not including limits of error of thermocouple)
Resolution 0.1 °C, 32.18 °F
Measurement Interval Typically, 3.5 s
Tilt
Sensor Type Electronic
Measurement Range 0 to 90° from horizontal
Accuracy ±2° typical (0 to 45°)
General
Measurement Cynchronization with I-V Curve Typically, <1 s
Wireless Range (open line of sight) 100 m, 328 ft 
Operating Temperature Range 0 ºC to 45 ºC, 32 ºF to 113 ºF
Storage Temperature Range -20 ºC to 65 ºC, -4 ºF to 149 ºF
Operating Humidity <90% RH, non-condensing. Avoid exposing a cold instrument to warm and humid air as condensation will result. Store the instrument in the same conditions in which the instrument will be used.
Battery Charging Time 6 hr
Battery Run Time >16 hr typical use

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA