Specifications
Output voltage 240 V ac rms or dc ±10 % ≥1 MΩ
LoZ >3 kΩ load 60 V ac typical
50 V ac rms minimum
LED power indicator Turns on when output voltage is present
Battery 4 x AA Alkaline batteries NEDA 24 A IEC LR03
Battery life 5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load
Operating temperature -10 °C to +50 °C
Operating humidity 0 % to 90 % (0 °C to 35 °C) 0 % to 70 % (35 °C to 55 °C)
Operating altitude 2000 m
Dimensions 11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2
Weight 0.23 kg (8 oz) includes batteries
Safety IEC61010-1, IEC61010-2-030
Certification CSA-CUS, CE
Warranty One Year
Electromagnetic Compatibility (EMC) IEC 61326-1 Portable EM environment; CISPR 11, Group 1, Class A
US (FCC) 47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes
 

Description

Fluke PRV240 Proving Unit

Unique, compact, convenient

The Fluke PRV240 Proving Unit is a portable, pocket-sized, battery-powered voltage source. It is unique in that it sources stable ac and dc voltages for both LoZ and HiZ instruments.

Fluke PRV240 Proving Unit Includes:

  • TPAK hanging strap
  • Four AA batteries
  • Instruction sheet

Designed for safety and compliance
The Fluke PRV240 proving unit provides a safe and easy method for verifying proper operation of your test tool before attempting to test for either an energized source or a de-energized source without the need for cumbersome PPE, or in cases where no known voltage source is available. Your environment may still require minimal PPE such as hard, safety glasses or earplugs when using a proving unit.

The PRV240 reduces the risk of shock and arc flash by removing unnecessary exposure to a potentially hazardous electrical environment while verifying the functionality of test tools before and after absence or presence of voltage is checked.

The PRV240 reduces the risk of shock and arc flash by validating the functionality of test tools without placing yourself in a potentially hazardous electrical environment

  • Sources both ac and dc steady-state voltage - supplies 240 V dc/ac
  • A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
  • Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
  • Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
  • Includes Magnetic Hanging Strap
  • Long battery life - 5,000 tests per set of four AA batteries

Features & Specification

More Information
Key Features LED Indication, Batteries Included, 240V Proving Unit
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description
Specifications
Output voltage 240 V ac rms or dc ±10 % ≥1 MΩ
LoZ >3 kΩ load 60 V ac typical
50 V ac rms minimum
LED power indicator Turns on when output voltage is present
Battery 4 x AA Alkaline batteries NEDA 24 A IEC LR03
Battery life 5000 (5-second duration) test cycles with >1 MΩ load, 300 tests minimum with >3 kΩ load
Operating temperature -10 °C to +50 °C
Operating humidity 0 % to 90 % (0 °C to 35 °C) 0 % to 70 % (35 °C to 55 °C)
Operating altitude 2000 m
Dimensions 11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2
Weight 0.23 kg (8 oz) includes batteries
Safety IEC61010-1, IEC61010-2-030
Certification CSA-CUS, CE
Warranty One Year
Electromagnetic Compatibility (EMC) IEC 61326-1 Portable EM environment; CISPR 11, Group 1, Class A
US (FCC) 47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes
 

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA