Specifications
Nominal current range:
40 A Range  0.5 A to 40 A
400 A Range  5 A to 400 A
Basic accuracy:
40 A Range  2% + 0.015 A (45-400 Hz)
400 A Range  2% + 0.04 A (45-400 Hz)
Phase Shift:
40 A Range  
0.5 to 1 A  Unspecified
1 A to 5 A  4°
5 A to 10 A  3°
10 A to 20 A  3°
20 A to 40 A  2°
40 A to 400 A  NA
400 A Range  
0.5 to 1 A  NA
1 A to 5 A  NA
5 A to 10 A  Unspecified
10 A to 20 A  2°
20 A to 40 A  2°
40 A to 400 A  1.5°
Typical Bandwidth:
40 A Range  5 Hz - 10 kHz
400 A Range  5 Hz - 10 kHz
Output level(s):
40 A Range  10 mV/A
400 A Range  1 mV/A
Crest Factor:
40 A Range  ≤ 3
400 A Range  ≤ 3 to 300 A
   ≤ 2.5 to 400 A

 

Safety Specifications
Safety
   CAT IV 600 V, CAT III, 1000 V
Maximum Non-Destructive Current
   1000 V AC

 

Mechanical & General Specifications
Warranty
   1 year
Maximum conductor size
   32 mm (1.25 inches)
Output cable length
   2.5 m (8.2 ft)
BNC Adapter
   Yes
Dimensions
   150 x 70 x 30 mm
Weight
   114 g

Description

Fluke i400s CAT IV AC current clamp for DMM's

 

Fluke current clamps extend the current ranges of digital multimeters, power quality analyzers, and portable oscilloscopes and are available for both AC and AC/DC environments. The Fluke i400s is specially designed to offer maximum utility in a compact shape and is the only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating.


Key Features:

  • Companion to your scope or power quality meter to measure up to 400 A AC
  • Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating
  • Specially designed to offer maximum utility in a compact shape
  • Take accurate current readings without breaking the circuit
  • Soft non-slippery overmold handle
  • Optional PM9081/001 BNC/Banana adapter for DMM's
  • Two ranges: 40 A and 400 A, 10 and 1 mV/Amp output
  • Max. conductor Ø 32 mm
 

ISSWWW and Fluke Instruments

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software.

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, metrologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Fluke are a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. Our sales staff and our technicians are Fluke trained and we hold perhaps the largest stock of their products in the country. Our customers know that when it comes to Fluke products, we have not only the best prices but the best advice and support services, reassuring when you need to make that all important purchase.
 
 


Features & Specification

More Information
Key Features Measures 1A to 400A, AC Current Clamp, BNC Adaptor
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description
Specifications
Nominal current range:
40 A Range  0.5 A to 40 A
400 A Range  5 A to 400 A
Basic accuracy:
40 A Range  2% + 0.015 A (45-400 Hz)
400 A Range  2% + 0.04 A (45-400 Hz)
Phase Shift:
40 A Range  
0.5 to 1 A  Unspecified
1 A to 5 A  4°
5 A to 10 A  3°
10 A to 20 A  3°
20 A to 40 A  2°
40 A to 400 A  NA
400 A Range  
0.5 to 1 A  NA
1 A to 5 A  NA
5 A to 10 A  Unspecified
10 A to 20 A  2°
20 A to 40 A  2°
40 A to 400 A  1.5°
Typical Bandwidth:
40 A Range  5 Hz - 10 kHz
400 A Range  5 Hz - 10 kHz
Output level(s):
40 A Range  10 mV/A
400 A Range  1 mV/A
Crest Factor:
40 A Range  ≤ 3
400 A Range  ≤ 3 to 300 A
   ≤ 2.5 to 400 A

 

Safety Specifications
Safety
   CAT IV 600 V, CAT III, 1000 V
Maximum Non-Destructive Current
   1000 V AC

 

Mechanical & General Specifications
Warranty
   1 year
Maximum conductor size
   32 mm (1.25 inches)
Output cable length
   2.5 m (8.2 ft)
BNC Adapter
   Yes
Dimensions
   150 x 70 x 30 mm
Weight
   114 g

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA