Fluke IRR1-SOL Solar Irradiance Meter

£326.34

Specifications: Fluke FLK-IRR1-SOL Solar Irradiance Meter

Irradiance
Measuring Range 0 to 1400 W/m²
Resolution 1 W/m²
Measuring Accuracy ± (5 % + 5 Digit)
Temperature Measurement
Measuring range (°C) -22 °F to 212 °F (-30 °C to 100 °C)
Resolution 0.2 °F (0.1 °C) / 1 °F @>100 °F
Measuring Accuracy ±2 °F (±1 °C) @ 14 °F to 167 °F (-10 °C to 75 °C),
±4 °F (±2 °C) @ -22 °F to 14 °F (-30 °C to -10 °C) and 167 °F to 212 °F (75 °C to 100 °C)
Note: Temperature measurement response time: ~30 sec.
Inclination Angle
Measuring Range -90° to +90°
Resolution 0.1°
Measuring Accuracy ± 1.5°@ -50° to +50°, ±2.5° @ -85° to -50° and +50° to +85°, ±3.5° @ -90° to -85° and +85° to +90°
Compass
Measuring Range 0° to 360°
Resolution
Measuring Accuracy ±7°
Note:
a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown "---".
b) Result is referred to magnetic north.
Temperature
Operating Temperature IRR1-SOL -20 °C to 50 °C (humidity <80%), noncondensing
Operating Temperature 80PR-IRR -30 °C to +100 °C
Storage Temperature -30 °C to 60 °C (humidity <80%)
Altitude 0 m to max. 2000 m
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Protection
IP Protection IP40
Power Supply & Battery Life
Batteries 4 AA Alkaline Batteries
Battery Life (typical) 50 hours (≤9000 readings)
Auto Power Off 30 minutes
Dimensions
L x W x H 5.90 x 3.14 x 1.37 in (150 x 80 x 35 mm)
Weight 0.5 lb (231 g)

Description

Fluke FLK-IRR1-SOL Solar Irradiance Meter

 

If you’re surveying, installing, executing maintenance or checking performance of solar panels or a photovoltaic system, the Fluke IRR1-SOL Irradiance Meter gives you the 4 critical measurements needed all in one easy-to-use tool. Make instantaneous measurements to determine the watt per square meter solar irradiation, required by IEC 62446-1 standard. Measure temperature by either placing the meter directly on the panel or by connecting the external probe. Find cardinal direction with the compass, and verify inclination of a roof or panel with the tilt function.

To find the expected production at a site, determine your solar resource while taking shading into account. The solar resource is measured in peak sun hours: the number of hours per day with 1,000 watts generated per square meter of solar array. Location, time of day, season, and weather conditions all influence peak sun hours. Use the Fluke IRR1-SOL to determine the actual solar irradiance (Watts/m²) and shading at the site to develop a baseline. Once your system is installed, make sure it is operating as designed by measuring its electrical characteristics and the actual power output of the array.

The performance of a photovoltaic array is based on its current-voltage (IV) curve. Use the IRR1-SOL to obtain the amount of solar irradiance necessary to calculate the IV curve of the power output. Even when installed correctly, a photovoltaic system may not be producing the expected electrical output. In order to produce the expected output the system needs to receive the correct amount of irradiance energy to generate the DC voltage that is fed into the inverter.

Whether working on a roof-mounted system or on a large field installation, the IRR1-SOL is the single-handed solution that every solar installer and technician needs in their tool bag.


Fluke IRR1SOL Comes Supplied With:

  • FLK-IRR1-SOL Solar Irradiance Meter
  • FLK80PR-IRR External Temperature Probe with Suction Cup
  • C250 Carrying Case with Shoulder Strap
  • (4) AA Alkaline Batteries (installed)
  • User Manual


Make the critical measurements needed for installing, testing, maintaining, and reporting on
solar panels or photovoltaic systems with one, easy-to-use tool.


The Fluke IRR1-SOL Irradiance Meter has been designed from the
ground up to simplify the installation, commissioning, and troubleshooting of photovoltaic arrays, measuring irradiance, temperature, inclination and direction of the solar array in a single handheld tool. With a rugged, compact design, a protective carrying case, and an easy-to-read, high-contrast LCD screen to read measurements in direct sunlight, the IRR1-SOL can go where you go.
The simple user interface, instantaneous solar irradiation measurements and built-in temperature sensor make it easy to meet the IEC 62446-1 requirements for testing, documenting, and maintaining photovoltaic systems. Additionally, the integrated compass and inclination sensor allow you to quickly measure and document roof and site orientation, pitch, and panel tilt while surveying, installing, or adjusting an installation.
Whether working on a roof-mounted system or on a large field installation, the IRR1-SOL is the single-handed solution that every solar installer and technician needs in their tool bag.

Use the IRR1-SOL for:
Photovoltaic system design and surveying to find the expected production at a site, determine your solar
resource while taking shading into account. The solar resource is measured in peak sun hours: the number of hours per day with 1,000 watts generated per square meter of solar array.
Location, time of day, season, and weather conditions all influence peak sun hours. Use the Fluke IRR1-SOL to determine the actual solar irradiance (Watts/m²) and shading at the site to develop a baseline.

Measuring:
Once your system is installed, make sure it is operating as designed by measuring its electrical characteristics and the actual power output of the array. The performance of a photovoltaic array is based on its current-voltage (IV) curve.
Use the IRR1-SOL to obtain the amount of solar irradiance necessary to calculate the IV curve of the power output.
Comparing and diagnosing Even when installed correctly, a photovoltaic system may not be producing the expected electrical output. In order to produce the expected output the system needs to receive the correct amount
of irradiance energy to generate the DC voltage that is fed into the
inverter.

 

isswww and Fluke Instruments 

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software. 

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products. 

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, meteorologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities. 

Fluke are a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. Our sales staff and our technicians are Fluke trained and we hold perhaps the largest stock of their products in the country. Our customers know that when it comes to Fluke products, we have not only the best prices but the best advice and support services, reassuring when you need to make that all-important purchase.  

Features & Specification

More Information
Key Features Essential solar test equipment, Irradiance measurements up to 1400 W/m², Dual Option Temperature Measurement, Case Included, Integrated Compass, Inclination Sensor
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description

Specifications: Fluke FLK-IRR1-SOL Solar Irradiance Meter

Irradiance
Measuring Range 0 to 1400 W/m²
Resolution 1 W/m²
Measuring Accuracy ± (5 % + 5 Digit)
Temperature Measurement
Measuring range (°C) -22 °F to 212 °F (-30 °C to 100 °C)
Resolution 0.2 °F (0.1 °C) / 1 °F @>100 °F
Measuring Accuracy ±2 °F (±1 °C) @ 14 °F to 167 °F (-10 °C to 75 °C),
±4 °F (±2 °C) @ -22 °F to 14 °F (-30 °C to -10 °C) and 167 °F to 212 °F (75 °C to 100 °C)
Note: Temperature measurement response time: ~30 sec.
Inclination Angle
Measuring Range -90° to +90°
Resolution 0.1°
Measuring Accuracy ± 1.5°@ -50° to +50°, ±2.5° @ -85° to -50° and +50° to +85°, ±3.5° @ -90° to -85° and +85° to +90°
Compass
Measuring Range 0° to 360°
Resolution
Measuring Accuracy ±7°
Note:
a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown "---".
b) Result is referred to magnetic north.
Temperature
Operating Temperature IRR1-SOL -20 °C to 50 °C (humidity <80%), noncondensing
Operating Temperature 80PR-IRR -30 °C to +100 °C
Storage Temperature -30 °C to 60 °C (humidity <80%)
Altitude 0 m to max. 2000 m
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Protection
IP Protection IP40
Power Supply & Battery Life
Batteries 4 AA Alkaline Batteries
Battery Life (typical) 50 hours (≤9000 readings)
Auto Power Off 30 minutes
Dimensions
L x W x H 5.90 x 3.14 x 1.37 in (150 x 80 x 35 mm)
Weight 0.5 lb (231 g)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA