Fluke Connect 3000 FC Wireless Multimeter
Detailed Specifications | |||
AC Voltage | |||
Range 1 | Resolution | Accuracy 2 3 4 | |
45 Hz to 500 Hz | 500 Hz to 1 kHz | ||
600.0 mV | 0.1 mV | 1.0 % + 3 | 2.0 % + 3 |
6.000 V | 0.001 V | ||
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V | ||
1 All AC voltage ranges are specified from 1 % of range to 100 % of range. 2 Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3. 4 Do not exceed 107 V-Hz. |
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | |||
Function | Range | Resolution | Accuracy |
mV | 600.0 mV | 0.1 mV | 0.09 % + 2 |
V | 6.000 V | 0.001 V | 0.09 % + 2 |
60.00 V | 0.01 V | ||
600.0 V | 0.1 V | ||
1000 V | 1 V | 0.15 % + 2 | |
Ω | 600 Ω | 1 Ω | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. |
Ω | 600.0 Ω | 0.1 Ω | 0.5 % + 2 |
6.000 kΩ | 0.001 kΩ | 0.5 % + 1 | |
60.00 kΩ | 0.01 kΩ | ||
60.00 kΩ | 0.1 kΩ | ||
600.0 kΩ | 0.001 MΩ | ||
50.00 MΩ | 0.01 MΩ | 1.5 % + 3 | |
Diode test | 2.000 V | 0.001 V | 1 % + 2 |
µF | 1000 nF | 1 nF | 1.2 % + 2 |
10.00 μF | 0.01 μF | ||
100.0 μF | 0.1 μF | ||
9999 μF1 | 1 μF | 10 % typical | |
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2. |
AC and DC Current | |||
Function | Range 1 | Resolution | Accuracy |
mA AC (45 Hz to 1 kHz) |
60.00 mA | 0.01 mA | 1.5 % + 3 |
400.0 mA 3 | 0.1 mA | ||
mA DC 2 | 60.00 mA | 0.01 mA | 0.5 % + 3 |
400.0 mA 3 | 0.1 mA | ||
1 All AC current ranges are specified from 5 % of range to 100 % of range. 2 Input burden voltage (typical): 400 mA input 2 mV/mA. 3 400.0 mA accuracy specified up to 600 mA overload. |
Frequency | |||
Range | Resolution | Accuracy 1 | |
99.99 Hz | 0.01 Hz | 0.1 % + 1 | |
999.9 Hz | 0.1 Hz | ||
9.999 kHz | 0.001 kHz | ||
99.99 kHz | 0.01 kHz | ||
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. |
Input Characteristics | ||||||
Function | Overload protection |
Input impedance (nominal) |
Common mode rejection ratio (1 kΩ unbalance) | Normal mode rejection | ||
1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |||
1100 V RMS | > 10 MΩ < 100 pF | > 60 dB, DC to 60 Hz | ||||
1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |||
Open circuit test voltage | Full scale voltage | Typical short circuit current | ||||
To 6 MΩ | 50 MΩ | |||||
1100 V RMS | < 2.7 V DC | < 0.7 V DC | < 0.9 V DC | < 350 mA | ||
1100 V RMS | < 2.7 V DC | 2.000 V DC | < 1.1 mA |
mA Function | |
Overload Protection | Fused, 44/100 A, 1000 V FAST Fuse |
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum |
MIN/MAX Recording Accuracy | |
DC functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. |
AC functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. |
General Specifications | |
Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS |
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
Display (LCD) | Update rate: 4/sec Volts, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 |
Battery life | 250 hours minimum |
RF communications | 2.4 GHZ ISM Band |
RF communication range | Open air, unobstructed: Up to 20m Obstructed, sheetrock wall: Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m |
Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C |
Temperature coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Relative humidity | 0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C) |
Altitude | Operating: 2,000 m Storage: 12,000 m |
Electromagnetic compatibility EMI, RFI, EMC, RF |
EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
Certifications | CSA, FCC, CE |
Ingress Protection (IP) rating | IP54 |
Pollution degree | 2 |
Size (H x W x L) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) |
Weight | 340 g (12 oz) |
Warranty | Three years |
Note: Not compatible with Fluke CNX test tools
Description
Fluke Connect 3000 Wireless Multimeter
With its precision, reliability and ease of use, the Fluke 3000 FC Wireless Multimeter is the ideal solution for professional technicians. Independently tested for safe use in CAT IV 600V/ CAT III 1000 V environments, the Fluke 3000 FC has all the features you need to troubleshoot and repair many problems in electrical and electronic systems.
The Fluke 3000 FC gives you true-RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging and provide frequency, capacitance, resistance, continuity and diode measurements. In addition, the Fluke 3000 FC provides higher 0.09% basic accuracy, a digital display showing up to three secondary measurements from remote modules, and a bright white backlight.
The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting.
- AC and DC voltage measurements to 1000V
- AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX Recording
- CAT III 1000 V, Cat IV 600 V; IP54
- True-RMS Wireless Multimeter
- TL175 Test Leads
- AC175 Alligator Clips
Work safely near electrical panels while wearing less PPE
The Fluke 3000 FC True-RMS Wireless Multimeter and Fluke Connect wireless test tools put tools, not your body, near live electrical panels. It's simple. Just de-energize the cabinet, open the panel while wearing PPE and connect the remote modules, whether they are voltage modules, current clamps, flexible current loops or thermometers. Then read the results on the 3000 FC Wireless Multimeter from a safe distance. You can display the meter measurement, plus readings from up to 3 wireless modules, while reducing the risk of arc flash by separating yourself from hazardous measurement situations.
Better still, the Fluke 3000 FC Series Wireless Multimeter can send measurement data to your smartphone, so you can save and share measurements from the field with your team anytime, from anywhere.
Don't get bogged down while chasing interrelated events
Timing is everything when trying to find the cause of a complex problem. Often you need to make a measurement in one place and see activity on a different part of the system at the same time. We've solved that problem with Fluke Connect - connect your remote modules in one location, then take your measurements up to 20 meters away with the Fluke 3000 FC multimeter. You'll be able to see the interaction between your remote test points on one single screen, in real time. You can even download the data to a PC for further analysis.
Other capabilities of Fluke Connect and the FC 3000 Multimeter
- Add your laptop and go from logging to analysis and diagnosis.
- Record over time using the Fluke Connect wireless modules and monitor circuit load changes for an hour, a shift or a week.
- Use the Fluke Connect wireless USB adapter to collect logged data from remote modules by walking past a working module and downloading logged data.
- Perform for analysis with your PC and share the results using Fluke Cloud™ storage and ShareLive™ video call. View data or graphs to get input from team members.
Features & Specification
Key Features | Test leads included, Cutting edge technology, Tough, durable material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Manufacturer | Fluke Testers | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Short Description |
Note: Not compatible with Fluke CNX test tools DeliveryUpdated January 2024
Please note, our cut-off time is 2:00pmOrders requiring calibrationWhilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery. Bank/Public HolidaysPredicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order. *UK Mainland (Revised March 2021)
Delivery SurchargesBecause of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
Offshore ServicesAll offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles. International deliveryInternational delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk ExportAll export inquiries should be directed to the export division before placement of order. If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
|