Fluke 902 FC TRMS HVAC Clamp Meter

£304.80
Function
A ac (via Jaw)
Resolution 0.01/0.1 A
Accuracy 2.0% ±5 digit (45-65 Hz)
2.5% ±5 digit (65-400 Hz)
Range 60.00/600.0 A
Crest Factor (50Hz or 60Hz) 2.5 MIN@220 A
3.0 MIN@180 A
> 1.4 MIN@600 A
Add 2% for CF>400 A
V ac
Resolution 0.1 V
Accuracy 1.5% ±5 digits
Range 600.0 V
V dc
Resolution 0.1 V
Accuracy 1.5% ±5 digits
Range 600.0 V
Ohms
Resolution 0.1/1/10
Accuracy 1% ±5 digits
Range 600/6000/60.00 kΩ
Capacitance
Resolution 0.1/1 µF
Accuracy 1% ±4 digits
Range 100.0/1000 µF
µA
Resolution 0.1 µA
Accuracy 1% ±5 digits
Range 200 µA
Contact temperature
Resolution 0.1 C/F
Accuracy 1% ±8 digits
Range -10 to 400 °C (14 °F to 752 °F)
Continuity beeper
Beeper volume 75 dBA nom. 15 cm. from case front
On threshold <=30 Ω
Mechanical and General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6
Temperature Operating: -10 °C to +50 °C (14 °F to +122 °F)
Storage: -40 °C to +60 °C (-40 °F to +140 °F)
Operating humidity Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))
Altitude Operating: 3,000 m (9,842 ft)
Storage: 12,000 m (39,370 ft)
Dimensions 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)
Weight (meter only) 419 g (15 oz)
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
IP Rating IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID:T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C

Description


Fluke 902 FC True-rms HVAC Clamp Meter

Enables HVAC technicians to create reports and collaborate with peers from the work site

 

The Fluke 902 FC True-rms HVAC Clamp Meter, a wireless Fluke Connect®-enabled meter, improves the productivity of HVAC technicians in the field. The rugged dual rated - CAT III, 600 /CAT IV, 300 V - meter performs the essential measurements of HVAC systems — microamps for testing pilot light sensors, resistance up to 60 kilohms, AC current, AC/DC voltage, capacitance and contact temperature — eliminating the need to carry multiple tools. Its small body is easy to hold and the jaw fits perfectly in tight work spaces.

 

Fluke 902 FC Comes Supplied With:

  • TL75 test leads (1 pair)
  • 80BK integrated DMM temperature probe (1)
  • AA alkaline batteries (2)
  • Soft carrying case
  • User's manual
  • Statement of calibration
 

As part of Fluke Connect — the industry’s largest system of software and more than 40 wireless test tools — the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. Those measurements can be uploaded to the cloud. Technicians can combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email and collaborate in real time with other colleagues with ShareLive™ video calls or email, increasing productivity in the field.

The clamp meter also decreases the frequency that technicians will need to wear personal protective equipment when working on high voltage/current panels. Simply turn off the panel, verify the panel is de-energized using standard safety procedures, place the clamp and sync it to a smartphone with the Fluke Connect app, close the panel, reenergize it, and take measurements from a safe distance.

 

Applications for HVAC

  • 200 µA DC current measurements to measure flame rod
  • Extended resistance range to measure thermistors up to 60kΩ
  • Capture flue gas temperature
  • Measure start and run motor capacitors
  • Measure performance of variable frequency drives
 

Fluke Connect

  • Fluke Connect connects your meter to your phone through Bluetooth to help you get more done faster and safer
  • Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
  • Troubleshoot better by instantly trending and monitoring measurements live on your phone screen
  • Create and email reports right from the field. Report not enough? Fluke Connect has ShareLive video calls that stream live video and measurements in the same screen
  • Don't stop to write down results, save them directly from your meter to your phone with the press of a button
 

Measurement capability

  • 600 A ac current measurement
  • 600 V ac and dc voltage measurement
  • Temperature measurement from -10 °C to 400 °C (14 °F to 752 °F)
  • 1000 µF capacitance measurement
  • DC Current measurement to 200 µA
  • True-rms voltage and current for accurate measurements on non-linear signals
  • Resistance measurement to 60 kΩ
  • Min and max recording to capture variations automatically
 

Other features

  • CAT III 600V, CAT IV 300V safety rating
  • TPAK magnetic strap (optional) allows you to conveniently hang the meter while using the probes
  • Ergonomic design fits in your hand and can be used while wearing personal protective equipment
  • Large, easy-to-read backlit display
  • Three-year warranty
  • Soft carrying case

Features & Specification

More Information
Key Features Current AC/DC, Tests Above 400A, TRMS, Backlit LED Screen, Data Hold
Manufacturer Fluke Testers
Short Description
Function
A ac (via Jaw)
Resolution 0.01/0.1 A
Accuracy 2.0% ±5 digit (45-65 Hz)
2.5% ±5 digit (65-400 Hz)
Range 60.00/600.0 A
Crest Factor (50Hz or 60Hz) 2.5 MIN@220 A
3.0 MIN@180 A
> 1.4 MIN@600 A
Add 2% for CF>400 A
V ac
Resolution 0.1 V
Accuracy 1.5% ±5 digits
Range 600.0 V
V dc
Resolution 0.1 V
Accuracy 1.5% ±5 digits
Range 600.0 V
Ohms
Resolution 0.1/1/10
Accuracy 1% ±5 digits
Range 600/6000/60.00 kΩ
Capacitance
Resolution 0.1/1 µF
Accuracy 1% ±4 digits
Range 100.0/1000 µF
µA
Resolution 0.1 µA
Accuracy 1% ±5 digits
Range 200 µA
Contact temperature
Resolution 0.1 C/F
Accuracy 1% ±8 digits
Range -10 to 400 °C (14 °F to 752 °F)
Continuity beeper
Beeper volume 75 dBA nom. 15 cm. from case front
On threshold <=30 Ω
Mechanical and General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Battery type 2 AA alkaline batteries, NEDA 15A, IEC LR6
Temperature Operating: -10 °C to +50 °C (14 °F to +122 °F)
Storage: -40 °C to +60 °C (-40 °F to +140 °F)
Operating humidity Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))
Altitude Operating: 3,000 m (9,842 ft)
Storage: 12,000 m (39,370 ft)
Dimensions 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)
Weight (meter only) 419 g (15 oz)
Safety IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
IP Rating IEC 60529: IP30, non-operating
Radio Frequency Certification FCC ID:T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC) International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficients Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C
Product Stock Status Next Day Delivery (subject to availability)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA