Fluke 62 Max Plus Infrared Thermometer

£131.94
Specifications

Temperature Range

Fluke 62 MAX  -30 °C to 500 °C (-22 °F to 932 °F)
Fluke 62 MAX+  -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
Fluke 62 MAX  ±1.5 °C or ±1.5% of reading, whichever is greater
 -10 °C to 0 °C: ±2.0
 -30 °C to -10 °C: ±3.0
Fluke 62 MAX+  ±1.0 °C or ±1.0% of reading, whichever is greater
 -10 °C to 0 °C: ±2.0
 -30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX  <500 ms (95% of reading)
Fluke 62 MAX+  <300 ms (95% of reading)
Spectral Response  8 to 14 microns
Emissivity  0.10 to 1.00

Optical Resolution

Fluke 62 MAX  10:1 (calculated at 90% energy)
Fluke 62 MAX+  12:1 (calculated at 90% energy)
Display Resolution
   0.1 °C (0.2 °F)
Repeatability of Readings
Fluke 62 MAX  ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater
Fluke 62 MAX+  ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
 AA battery
Battery Life
Fluke 62 MAX  10 hours with laser and backlight on
Fluke 62 MAX+  8 hours with laser and backlight on

Physical Specifications

Weight  255 g (8.99 oz)
Size  (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature  0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature  -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity  10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude  2000 meters above mean sea level
Storage Altitude  12,000 meters above mean sea level
IP Rating  IP 54 per IEC 60529
Drop Test  3 meters
Vibration and Shock  IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC  EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance  EN/IEC 61010-1: 2001
Laser Safety  FDA and EN 60825-1 Class II

Description

Fluke 62 Max Plus Infrared Thermometer

Small in size. Big on toughness

 

Why IR Thermometers?

Temperature is often the first indication of potential problems in electrical and mechanical applications. But how can you easily determine if an electrical panel has a hot spot, a motor is overheating or an HVAC system is inefficient? The answer is with an infrared (IR) thermometer. With handheld, non-contact IR thermometers, you can instantly measure equipment temperatures in hard-to-reach or hazardous areas. And with early detection of abnormal temperatures comes early correction of problems.

 

Fluke 62 MAX and Fluke 62 MAX Plus

Designed with your on-the-job needs in mind, the new Fluke 62 MAX and 62 MAX Plusinfrared thermometers are everything you’d expect from the experts in measurement tools. Small in size, extremely accurate and very easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop. In fact, the 62 MAX and 62 MAX+ are so tough, they’re the only IR thermometers around you can handle without care.

 

key Features:

  • Dust and water-resistant: IP54 rated for dust and water resistance.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box

 

 Additional Features:

  • Distance to spot: Precise laser technology makes for more accurate and repeatable measurements.
  • Dual lasers: The 62 MAX+ has dual rotating lasers to help you identify area to be measured. The measurement area is the spot between the dots.
  • Large, backlit display: Large screen makes data easier to read, even in dark areas.
  • Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements.
  • Alarm: Hi and Lo alarms for rapid display of measurements outside the limits.
  • Power: Both the 62 MAX and 62 MAX+ are powered by a single, standard AA battery.

Features & Specification

More Information
Key Features -30 °C to 650 °C, Adjustable Emissivity, Dual Laser, Min/Max/Avg/Dif
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description
Specifications

Temperature Range

Fluke 62 MAX  -30 °C to 500 °C (-22 °F to 932 °F)
Fluke 62 MAX+  -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy
Fluke 62 MAX  ±1.5 °C or ±1.5% of reading, whichever is greater
 -10 °C to 0 °C: ±2.0
 -30 °C to -10 °C: ±3.0
Fluke 62 MAX+  ±1.0 °C or ±1.0% of reading, whichever is greater
 -10 °C to 0 °C: ±2.0
 -30 °C to -10 °C: ±3.0
Response Time (95%)
Fluke 62 MAX  <500 ms (95% of reading)
Fluke 62 MAX+  <300 ms (95% of reading)
Spectral Response  8 to 14 microns
Emissivity  0.10 to 1.00

Optical Resolution

Fluke 62 MAX  10:1 (calculated at 90% energy)
Fluke 62 MAX+  12:1 (calculated at 90% energy)
Display Resolution
   0.1 °C (0.2 °F)
Repeatability of Readings
Fluke 62 MAX  ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater
Fluke 62 MAX+  ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power
 AA battery
Battery Life
Fluke 62 MAX  10 hours with laser and backlight on
Fluke 62 MAX+  8 hours with laser and backlight on

Physical Specifications

Weight  255 g (8.99 oz)
Size  (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature  0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature  -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity  10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude  2000 meters above mean sea level
Storage Altitude  12,000 meters above mean sea level
IP Rating  IP 54 per IEC 60529
Drop Test  3 meters
Vibration and Shock  IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC  EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance  EN/IEC 61010-1: 2001
Laser Safety  FDA and EN 60825-1 Class II

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA