Infrared temperature range -40°C to 800°C (-40°F to 1472°F)
Infrared accuracy < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple type-k input temperature range -270°C to 1372°C (-454°F to 2501°F)
Thermocouple type-k input accuracy < -40°C: ±(1°C + 0.2°/1°C)
≥ -40°C: ±1% or 1°C, whichever is greater < -40°F: ±(2°F + 0.2°/1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
D:S (distance to measurement spot size) 50:1
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable celsius and fahrenheit Yes
Power 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
Battery life 4 hours with laser and backlight on; 
100 hours with laser and backlight off, at 100% duty cycle
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-40°F to 140°F)
Bead thermocouple type-k range -40°C to 260°C (-40°F to 500°F)
Bead thermocouple type-k accuracy ±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F), 
typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)

Description

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in hazardous environments anywhere in the world

 

The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.

 

Fluke 568 Ex Comes Supplied With:

  • K-type thermocouple bead probe
  • Conductive IS hard carrying case
  • User’s manual

With a straight-forward user interface and soft-key menus, the Fluke 568 Ex makes even complex measurements easy. Quickly navigate and adjust emissivity, save data or turn on and off alarms, with just a few pushes of a button. All in a single intrinsically safe tool certified by major rating bodies from around the world.

 

With a rugged, easy-to-use, ergonomic design, the Fluke 568 can stand up to tough industrial, electrical, and mechanical environments.

  • Meets intrinsically safe certifications in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments from recognized safety agencies around the world
  • Measure -40 °C to 800 °C /-40 °F to 1472 °F
  • Conductive Case for carrying the IR thermometer safely into hazardous area
  • Easily access advanced features with the soft-key buttons and graphical display
  • Measure small objects from further away, with a distance-to-spot ratio of 50:1
  • Compatible with mini-connector K-type thermocouple (KTC) probe
  • Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table
  • Capture up to 99 points of data
  • Confidently troubleshoot equipment with ± 1 % measurement accuracy
  • Versatile interface with five languages from which to choose
  • Two-year warranty

About Intrinsically Safe Products

Products that appear on this website that are listed as or relate to a classification of intrinsic safety are titled and described according to our best understanding and/or interpretation of the complex and sometimes changing criteria governing such classification as set out by the Health and Safety Executive.

Please note that due to the volatile nature of the intended use of products in this category,  neither UK Test Instruments or Instrument Sales and Service can be held responsible for any incident that arises from the purchase or use of any product described within this web site. For more information please visit the health and Safety Executive website with specific regard to Hazardous Area Classification and Control of Ignition Sources.

Features & Specification

More Information
Key Features Includes Software, Measures -40 °C to 800 °C, Type K input , Probe included, Data transfer via USB, Emissivity adjustment, Intrinsically Safe
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description

 

Infrared temperature range -40°C to 800°C (-40°F to 1472°F)
Infrared accuracy < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple type-k input temperature range -270°C to 1372°C (-454°F to 2501°F)
Thermocouple type-k input accuracy < -40°C: ±(1°C + 0.2°/1°C)
≥ -40°C: ±1% or 1°C, whichever is greater < -40°F: ±(2°F + 0.2°/1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
D:S (distance to measurement spot size) 50:1
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable celsius and fahrenheit Yes
Power 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
Battery life 4 hours with laser and backlight on; 
100 hours with laser and backlight off, at 100% duty cycle
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-40°F to 140°F)
Bead thermocouple type-k range -40°C to 260°C (-40°F to 500°F)
Bead thermocouple type-k accuracy ±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F), 
typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA