Fluke 393FC CATIII 1500V TRMS Solar Clamp Irradiance Meter Kit 5337401

£884.40
Fluke 393FC Clamp Meter technical Specification
General
Maximum voltage between any Terminal and Earth Ground
AC 1000 V
DC 1500 V
Batteries 2 AA IEC LR6 alkaline
Display Dual display with backlight
Automatic Power Off 20 minutes
Electrical 
Accuracy Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature Coefficients Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC Current: Jaw  
Range 999.9 A
Resolution 0.1 A
Accuracy 2 % + 5 digits (10 Hz to 100 Hz)
2.5 % + 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz) 2.5 @600.0 A
3.0 @500.0 A
1.42 @999.9 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range 999.9 A
  2500 A
Resolution 0.1 A (≤999.9 A)
1 A (≤2500 A)
Accuracy 3 % RD + 5 digits (10 Hz to 500 Hz)
Crest Factor (50/60Hz) 2.5 @1400 A
3.0 @1100 A
1.42@2500 A
Add 2 % for C.F. >2
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2 % RD + 5 digits[1]
Note [1] When using the ZERO (B) function to compensate for offsets.
AC Voltage 
Range 600.0 V
1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1 % RD + 5 digits (20 Hz to 500 Hz)
DC Voltage 
Range 600.0 V
1500 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1500 V)
Accuracy 1 % RD + 5 digits
mV DC
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1 % RD + 5 digits
Amps Frequency: Jaw 
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger Level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Amps Frequency: Flexible Current Probe
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger Level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage Frequency
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger Level 5 Hz to 20 Hz, ≥5 V
20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC Power 
Range 600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
Resolution 0.1 kVA
1 kVA
Accuracy 2 % RD + 2.0 kVA
2 % RD + 20 kVA
Resistance 
Range 600.0 Ω
6000 Ω
60.00 kΩ
Resolution 0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
0.01 kΩ (≤60.00 kΩ)
Accuracy 1 % RD + 5 digits
Capacitance
Range 100.0 μF
1000 μF
Resolution 0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy 1 % RD + 5 digits
Inrush Trigger Level 5 A
Mechanical
Size (L x W x H) 281 mm x 84 mm x 49 mm
Weight (with batteries) 520 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length (head to electronics connector) 1.8 m
Environmental 
Operating Temperature -10 °C to 50 °C
Storage Temperature -40 °C to 60 °C
Operating Humidity Non condensing (<10°C)
≤90 % RH (at 10 °C to 30 °C)
≤75 % RH (at 30 °C to 40 °C)
≤45 % RH (at 40 °C to 50 °C)
Operating Altitude 2000 m
Storage Altitude 12 000 m
Ingress Protection (IP) Rating IEC 60529: IP54 non-operating
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety 
General IEC 61010-1, Pollution Degree 2
Measurement IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless Radio
Radiofrequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless Radio Frequency Range 2400 MHz to 2483.5 MHz
Output Power <100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
NEW

Description

Fluke 393 FC CATIII 1500V TRMS Solar Clamp & Irradiance Meter Kit 5337401

 

Fluke 393IRRFC Comes Supplied With:

• Fluke 393 FC CAT III 1500 V TRMS clamp meter
• Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
• iFlex 18-inch flexible current probe
• TPAK magnetic hanging strap
• Premium carrying case
• 3-year warranty
• Pomona PVLEAD1 MC4 to 4 mm Test Lead Set
• Pomona PVLEAD3 MC4 Solar Clamp Test Lead Set


Additionally:

• FLK-IRR1-SOL Solar Irradiance Meter
• FLK80PR-IRR External Temperature Probe with Suction Cup
• C250 Carrying Case with Shoulder Strap


The 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is an industrial clamp meter is designed for solar photovoltaic (PV) installation technicians and maintenance professionals who work in high voltage dc environments. Safely connect the MC4 test leads to the clamp meter to validate voltage and current from individual panels or a series of panels in a PV array.
The PVLEAD1 solar MC4 test leads connect measuring devices to PV power plants, for use in regular tests, measurements, and troubleshooting on solar PV panels. The inline capabilities of the PVLEAD3 solar MC4 test leads allow the system to remain online and generating power while testing without needing to pierce the line. Use the IRR1-SOL to obtain the amount of solar irradiance necessary to calculate the IV curve of the power output. Validate that the panel or string of panels are outputting the correct voltage.

 

Take measurements on your
1500 V dc systems, safely.
 
1500 V dc systems are here. Now you can test these new installations with the only clamp meter designed for the task – the Fluke 393 FC CAT III 1500 V true-rms clamp meter. The world’s only CAT III 1500 V current clamp the 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is designed for technicians who work in dc environments up to 1500 V: solar arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies.
The clamp will measure up to 1500 V dc, 1000 V ac, and up to 999.9 A dc or ac
through the clamp jaw. The included iFlex flexible current probe extended ac current measurements up to 2500 amps. This clamp has a thin jaw, giving you access to cables in crowded combiner boxes.
Test leads are designed with your work in mind, and are also rated to CAT III 1500 V.

 

Key Features:

  • The world’s first and only clamp meter with a CAT III 1500 V safety rating.
  • 1500 V CAT III insulated test leads specifically designed for use in 1500 V dc environments.
  • Visual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
  • Plus more. A thin jaw to work in crowded combiner boxes. IP54 rating for use outdoors. Fluke Connect™ software to record, analyze and share results.
  • DC power measurement, showing readings in kVA
  • Audio Polarity indicator helps prevent accidental miswires
  • Logging and reporting of test results via Fluke Connect software
  • When measuring ac current the included iFlex flexible current
    probe gives you unparalleled access to cable is tight spaces.
    The iFlex probe can be twisted through extremely small spaces
    and provide accurate current measurements.


Fluke Connect:


MEASURE SAFELY
CAT III 1500 V rated clamp meter
VERSATILE CLAMP JAW
Thin jaw for access to cables in crowded combiner
boxes, able to clamp around multiple cables
IP54 RATED
Work outdoors in dusty or damp conditions
MORE FUNCTIONS, AUTOMATIC SAFEGUARDS
Work efficiently with dc power measurement,
audio polarity and visual continuity

 

isswww and Fluke Instruments

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software.

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, meteorologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Fluke are a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. Our sales staff and our technicians are Fluke trained and we hold perhaps the largest stock of their products in the country. Our customers know that when it comes to Fluke products, we have not only the best prices but the best advice and support services, reassuring when you need to make that all-important purchase.

Features & Specification

More Information
Key Features Essential solar test equipment, 1500V TRMS, CATIII Rated, iFlex 18 inch flexible current probe included, TPAK magnetic hanging strap included, Premium carrying case included, Pomona MC4 test leads included, Additional irradiance meter and temperature probe
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description
Fluke 393FC Clamp Meter technical Specification
General
Maximum voltage between any Terminal and Earth Ground
AC 1000 V
DC 1500 V
Batteries 2 AA IEC LR6 alkaline
Display Dual display with backlight
Automatic Power Off 20 minutes
Electrical 
Accuracy Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature Coefficients Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC Current: Jaw  
Range 999.9 A
Resolution 0.1 A
Accuracy 2 % + 5 digits (10 Hz to 100 Hz)
2.5 % + 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz) 2.5 @600.0 A
3.0 @500.0 A
1.42 @999.9 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range 999.9 A
  2500 A
Resolution 0.1 A (≤999.9 A)
1 A (≤2500 A)
Accuracy 3 % RD + 5 digits (10 Hz to 500 Hz)
Crest Factor (50/60Hz) 2.5 @1400 A
3.0 @1100 A
1.42@2500 A
Add 2 % for C.F. >2
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2 % RD + 5 digits[1]
Note [1] When using the ZERO (B) function to compensate for offsets.
AC Voltage 
Range 600.0 V
1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1 % RD + 5 digits (20 Hz to 500 Hz)
DC Voltage 
Range 600.0 V
1500 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1500 V)
Accuracy 1 % RD + 5 digits
mV DC
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1 % RD + 5 digits
Amps Frequency: Jaw 
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger Level 5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Amps Frequency: Flexible Current Probe
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger Level 5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage Frequency
Range 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % RD + 5 digits
Trigger Level 5 Hz to 20 Hz, ≥5 V
20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC Power 
Range 600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
Resolution 0.1 kVA
1 kVA
Accuracy 2 % RD + 2.0 kVA
2 % RD + 20 kVA
Resistance 
Range 600.0 Ω
6000 Ω
60.00 kΩ
Resolution 0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
0.01 kΩ (≤60.00 kΩ)
Accuracy 1 % RD + 5 digits
Capacitance
Range 100.0 μF
1000 μF
Resolution 0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy 1 % RD + 5 digits
Inrush Trigger Level 5 A
Mechanical
Size (L x W x H) 281 mm x 84 mm x 49 mm
Weight (with batteries) 520 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length (head to electronics connector) 1.8 m
Environmental 
Operating Temperature -10 °C to 50 °C
Storage Temperature -40 °C to 60 °C
Operating Humidity Non condensing (<10°C)
≤90 % RH (at 10 °C to 30 °C)
≤75 % RH (at 30 °C to 40 °C)
≤45 % RH (at 40 °C to 50 °C)
Operating Altitude 2000 m
Storage Altitude 12 000 m
Ingress Protection (IP) Rating IEC 60529: IP54 non-operating
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety 
General IEC 61010-1, Pollution Degree 2
Measurement IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless Radio
Radiofrequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless Radio Frequency Range 2400 MHz to 2483.5 MHz
Output Power <100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA