Fluke 381 Remote Display TRMS Clamp Meter

£694.80
Electrical Specifications
AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 999.9 A / 2500 A (45 Hz – 500 Hz)
Resolution 0.1 A / 1 A
Accuracy 3% ± 5 digits
Crest Factor (50/60 Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Distance from Optimum
  i2500-10 Flex i2500-18 Flex Error
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 600 V /1000 V
Resolution 0.1 V / 1 V
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 600.0 V /1000 V
Resolution 0.1 V / 1 V
Accuracy 1% ± 5 digits
Frequency – Via Jaw
Range 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥ 10 A
10 – 100 Hz, ≥ 5 A
100 – 500 Hz, ≥ 10 A
Frequency via Flexible Current Probe
Range 5.0 to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 to 20 Hz, ≥ 25 A
20 to 100 Hz, ≥ 20 A
100 to 500 Hz, ≥ 25 A
Resistance
Range 600 Ω/6 kΩ/60 kΩ
Resolution 0.1 Ω/1 Ω/10 Ω
Accuracy 1% ± 5 digits
Mechanical Specifications
Size (L x W x H) 277 x 88 x 43 mm (55 mm for remote unit)
Weight 350 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature -10°C to +50°C
Storage Temperature -40°C to +60°C
Operating Humidity Non condensing (< 10°C)
≤ 90% RH (at 10°C to 30°C)
≤ 75% RH (at 30°C to 40°C)
≤ 45% RH (at 40°C to 50°C)
(Without Condensation)
Operating Altitude 2,000 meters
Storage Altitude 12,000 meters
EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006
ETSI EN 300 489 V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID: T68-F381
RSS-210 IC: 6627A-F381
Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C
Wireless Frequency 2.4 GHz ISM Band 10 meter range
Safety Compliance ANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV.
Double Insulation Clearance Per IEC 61010-2-032
Double Insulation Creepage Per IEC 61010-1
Agency Approvals

Description

Fluke 381 Remote Display TRMS Clamp Meter

All the bells and whistles. Be ready for anything


The Fluke 381 does everything you would expect from a clamp meter, and then lets you remove the display for even more flexibility. Now one technician can do jobs that used to require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.

 

Fluke 381 Comes Supplied With:

  • 18-inch iFlex™ flexible current probe
  • Coated instruction card
  • Safety information sheet
  • Soft carrying case
  • TL75 test leads
  • Five AA Alkaline batteries

The iFlex flexible current probe (included) expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.

 

Key Features:

  • Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement for added flexibility without interference with measurement accuracy
  • The removable magnetic display can be conveniently mounted where it is easily seen
  • iFlex flexible current probe expands the measurement range to 2500 A ac
  • CAT IV 600 V, CAT III 1000 V
  • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty
  • Soft carrying case
 
  Fluke-365 Fluke-373 Fluke-374 Fluke-375 Fluke-376 Fluke-381
Measure ac current 200.0 A 600.0 A 600.0 A 600.0 A 999.9 A 999.9 A
Measure ac current via iFlex     2500 A 2500 A 2500 A 2500 A
Measure ac voltage 600.0 V 600.0 V 600.0 V 600.0 V 1000.0 V 1000.0 V
Measure continuity ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω
Measure dccurrent 200.0 A   600.0 A 600.0 A 999.9 A 999.9 A
Measure dc voltage 600.0 V   600.0 V 600.0 V 1000.0 V 1000.0 V
Measure resistance 6,000 Ω 6,000 Ω 6,000 Ω 60k Ω 60k Ω 60k Ω
Measure frequency       500 Hz 500 Hz 500 Hz
Measure inrush     100 mS 100 mS 100 mS 100 mS
Work in poorly lit areas Backlight Backlight Backlight Backlight Backlight Backlight
Measure non-linear loads True-rms True-rms True-rms True-rms True-rms True-rms

Features & Specification

More Information
Key Features Current AC/DC, TRMS, Backlit LED Screen, Data Hold, Resistance Measurement, Continuity Measurement, Tests Above 1000A, Frequency Measurement, Flexi Clamp Included
Manufacturer Fluke Testers
Short Description
Electrical Specifications
AC Current via Jaw
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 999.9 A / 2500 A (45 Hz – 500 Hz)
Resolution 0.1 A / 1 A
Accuracy 3% ± 5 digits
Crest Factor (50/60 Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Distance from Optimum
  i2500-10 Flex i2500-18 Flex Error
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 999.9 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 600 V /1000 V
Resolution 0.1 V / 1 V
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 600.0 V /1000 V
Resolution 0.1 V / 1 V
Accuracy 1% ± 5 digits
Frequency – Via Jaw
Range 5.0 – 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥ 10 A
10 – 100 Hz, ≥ 5 A
100 – 500 Hz, ≥ 10 A
Frequency via Flexible Current Probe
Range 5.0 to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 to 20 Hz, ≥ 25 A
20 to 100 Hz, ≥ 20 A
100 to 500 Hz, ≥ 25 A
Resistance
Range 600 Ω/6 kΩ/60 kΩ
Resolution 0.1 Ω/1 Ω/10 Ω
Accuracy 1% ± 5 digits
Mechanical Specifications
Size (L x W x H) 277 x 88 x 43 mm (55 mm for remote unit)
Weight 350 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature -10°C to +50°C
Storage Temperature -40°C to +60°C
Operating Humidity Non condensing (< 10°C)
≤ 90% RH (at 10°C to 30°C)
≤ 75% RH (at 30°C to 40°C)
≤ 45% RH (at 40°C to 50°C)
(Without Condensation)
Operating Altitude 2,000 meters
Storage Altitude 12,000 meters
EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006
ETSI EN 300 489 V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID: T68-F381
RSS-210 IC: 6627A-F381
Temperature Coefficients Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C
Wireless Frequency 2.4 GHz ISM Band 10 meter range
Safety Compliance ANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV.
Double Insulation Clearance Per IEC 61010-2-032
Double Insulation Creepage Per IEC 61010-1
Agency Approvals
Product Stock Status Next Day Delivery (subject to availability)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.