Fluke 2052 Advanced Wire Tracer Technical Specifications
  2052R Receiver 2000T Transmitter i400 AC Current Clamp
General
Measurement category CAT IV 600 V CAT IV 600 V CAT IV 600 V, CAT III 1000 V
Operating voltage 600 V AC/DC 600 V AC/DC 1000 V AC
Operating frequency Energized: 6.25 kHz
De-Energized: 32.768 kHz
Energized/Loop: 6.25 kHz
De-Energized: 32.768 kHz
N/A
Signal indications Numeric, bar graph display and audible beep LEDs and audible beep N/A
Response time Tip Sensor (Energized/ De-Energized): 500 ms
NCV: 500 ms
Battery monitoring: 5 s
Line voltage monitoring: 1 s Battery voltage monitoring: 5 s N/A
Current output
of signal (typical)
N/A Energized circuit:
High mode: 60 mA rms Low mode: 30 mA rms
De-energized circuit:
High mode: 110 mA rms Low mode: 40 mA rms
Loop mode with test leads: 160 mA rms
Loop mode with i400 AC Current Clamp: 385 mA rms
N/A
Signal voltage output (nominal) N/A Energized circuit:
High mode: 14 W @ 230 V ac/50 Hz,
3.33 kΩ @ 230 V ac
Low mode: 4.6 W @ 230 V ac/50 Hz,
11.5 kΩ @ 230 V ac
De-energized circuit:
High mode: 31 V RMS, 140 Vp-p,
0.86 W @ 1 kΩ load
Low mode: 27.5 V RMS, 120 Vp-p,
0.1 W @ 1 kΩ load
Loop mode with test leads: 32 V RMS, 140 Vp-p, 0.87 W @ 1 kΩ load
Loop mode with i400 AC Current Clamp: 31 mV, 0.89 W @ 1 Ω load
N/A
Range detection (open air) Tip Sensor: Energized
Max distance via air: up to 6.1 m (20 ft) Pinpointing: approx. 5 cm (1.97 in)
Tip Sensor: De-Energized
Max distance via air: up to 4.5 m (14.7 ft) Pinpointing: approx. 5 cm (1.97 in)
NCV (40 Hz to 400 Hz)
Max. sensitivity: 90 V up to 2 m Min. sensitivity: 600 V up to 1 cm
N/A N/A
Current range N/A N/A 400 A
Basic accuracy N/A N/A 2 % + 0.06 A
(45 Hz to 400 Hz)
  2052R Receiver 2000T Transmitter i400 AC Current Clamp
Display
Display size LCD 63 mm (2.5 in) LEDs N/A
Display dimensions (W x H) 37 mm x 49 mm (1.45 x 1.93 in) N/A N/A
Display Resolution 240 px x 320 px N/A N/A
Display type TFT LCD LEDs N/A
Display color 16-bit Operating mode LEDs: red
Battery status LEDs: green, yellow, red
N/A
Backlight Yes N/A N/A
Environmental
Operating temperature -20 °C to 50 °C
(-4 °F to 122 °F)
-20 °C to 50 °C
(-4 °F to 122 °F)
-20 °C to 50 °C
(-4 °F to 122 °F)
Operating humidity 45%: -20 °C to <10 °C or 40 °C to 50 °C
(-4 °F to <50 °F or 104 °F to 122 °F)
95% (non-condensing): 10 °C to <30 °C
(50 °F to 86 °F)
75%: 30 °C to <40 °C (86 °F to <104 °F)
45%: -20 °C to <10 °C or 40 °C to 50 °C
(-4 °F to <50 °F or 104 °F to 122 °F)
95% (non-condensing): 10 °C to <30 °C
(50 °F to 86 °F)
75%: 30 °C to <40 °C (86 °F to <104 °F)
10 °C to <30 °C
(95%: 50 °F to <86 °F)
30 °C to <40 °C
(75%: 86 °F to <104 °F)
40 °C to <50 °C
(45%: 104 °F to <122 °F)
Operating altitude 2000 m (6561 ft) 2000 m (6561 ft) 2000 m (6561 ft)
Transient protection N/A 8.00 kV (1.2/50μS surge) N/A
Pollution degree 2 2 2
IP rating IP 40 IP 40 IP 40
Drop test 1 m (3.28 ft) 1 m (3.28 ft) 1 m (3.28 ft)
Mechanical
Power supply 4 x AA (alkaline) 8 x AA (alkaline) N/A
Power consumption (typical) 110 mA High/low mode: 70 mA
Loop mode with Clamp: 90 mA
Consumption without signal transmission: 10 mA
N/A
Battery life Approx. 16 h High/low mode: approx. 25 h Loop mode: approx. 18 h N/A
Low battery indication Yes Yes N/A
Fuse N/A 1.6 A, 700 V, fast-acting,
Ø 6 x 32 mm, 50 kA interrupt
N/A
Maximum conductor size N/A N/A 32 mm (1.26 in)
Dimensions (L x W x H) Approx. 183 x 75 x 43 mm
(7.2 x 2.95 x 1.69 in)
Approx. 183 x 93 x 50 mm
(7.2 x 3.66 x 1.97 in)
Approx. 150 x 70 x 30 mm
(5.9 x 2.75 x 1.18 in)
Weight Approx.  0.27 kg (0.6 lb) Approx.  0.57 kg (1.25 lb) Approx.  0.114 kg (0.25 lb)
General
Includes 2x 1 m Test leads (red, black), 1x 7 m Test lead (green) 2x Test probes (black), 2x Alligator clips (red, black)
2x Outlet blade adapters (red, black), 2x Outlet round adapters (red, black)
Measurement category CAT IV 600 V (test leads), CAT II 1000 V (test probes), CAT IV 600 V (alligator clips), CAT II 300 V (outlet adapters)
Operating voltage and current 600 V, 10 A max. (red/black leads), 600 V, 10 A max. (green lead), 1000 V, 8 A max. (black probe) 600 V, 10 A max. (alligator clips), 300 V, 10 A max. (outlet adapters)
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Operating humidity 10 °C to <30 °C (95 %: 50 °F to <86 °F), 30 °C to <40 °C (75 %: 86 °F to <104 °F),
40 °C to <50 °C (45 %: 104 °F to <122 °F)
Storage temperature and humidity 0 °C to 60 °C (32 °F to 140 °F), <95 % (non-condensing)
Operating altitude 2000 m (6561 ft)
Pollution degree 2
Water and dust resistance IP 20
Drop proof 1 m (3.28 ft)
Dimensions Red/black leads: 1 m (3.28 ft), Green lead: 7 m (22.97 ft), Alligator clips: approx. 95 x 45 x 24 mm (3.74 x 1.77 x 0.94 in),
Outlet adapters: 72 x 18 x 18 mm (2.83 x 0.71 x 0.71 in)
Weight Approx. 0.4 kg (0.88 lb)
NEW

Description

Fluke 2052 Advanced Wire Tracer Kit 5353853

The 2052 and 2062 Advanced Wire Tracers are the newest product introductions from Fluke.
These wire tracers are designed for troubleshooting and locating wires behind walls, ceilings and floors in residential, commercial, and industrial environments.
The patented Smart Sensor technology on the Fluke 2062 and CAT IV 600 V safety rating on both models are features that differentiate these products from competitors.

Fluke 2052 Kit Comes Supplied With:

• Fluke 2052R Advanced Wire Tracer Receiver
• Fluke 2000T Advanced Wire Tracer Transmitter
• i400 AC Current Clamp
• Fluke 2000ACC Test Lead Accessory Kit for 2052/2062
• Premium hard carrying case
• Batteries
• Quick reference guide

Faster, Easier, Safer Troubleshooting

• Locate energized and de-energized wires quickly and accurately
• Find breaks or opens and shorts
• Identify breakers and fuses
• CAT IV 600 V

Built to keep you safe

The Fluke 2052 Advanced Wire Tracer accurately and safely troubleshoots energized and de-energized wires in residential, commercial, and industrial environments up to CAT IV 600 V. This CAT rating offers the highest protection available on any wire tracer. It’s designed to protect you from the most dangerous
levels of transient overvoltage, spikes up to 8,000 V, that can occur in industrial and utility environments. This is especially important for scenarios you may encounter in environments like industrial plants, factories, and hospitals where critical equipment cannot be taken offline.


Wire tracing customized for your application

Whether troubleshooting electrical wiring and equipment in residential homes, commercial buildings, or high-voltage utility plants, the Fluke 2052 can find breaks or opens and shorts.
Its different modes and functions give you the flexibility to troubleshoot a wide range of electrical wiring and circuitry problems you may encounter on the job.


Four receiver tracing modes

The 2052 Receiver detects the signal in wires and cables using two methods: passive tracing without the transmitter for non- contact voltage detection and active tracing with the transmitter for all other modes. The receiver’s tip sensor can trace wires in corners, tight spaces, and junction boxes.
• Quick Scan mode for quick signal identification
• Precision mode for more precise detection of a wire
• Breaker mode for easy breaker and fuse identification based on the highest recorded signal detected from the transmitter
• Non-contact voltage detection mode to trace energized wires without the use of the transmitter

Three transmitter power modes

The 2000T Transmitter works on energized and de-energized circuits up to CAT IV 600 V and features high, low, and loop modes. These modes change the strength of the induced signal and can help provide more accurate results, depending on the circuit you’re tracing.
• High mode for normal energized and de- energized circuits
• Low mode for precision tracing with a low signal to reduce coupling to nearby wires and metal objects
• Loop mode for closed loop de-energized circuits
Two transmitter output frequencies
The 2000T automatically senses whether the system is energized or de-energized and selects a 6 kHz or 33 kHz output frequency.
Eight receiver sensitivity levels More sensitivity levels mean more flexibility and accuracy when tracing.

Complete kit

The Fluke 2052 Advanced Wire Tracer Kit conveniently comes with everything required to start tracing wires and circuits. The accessory kit includes test leads, test probes, blade and round outlet adapters, and alligator clips to connect the transmitter to electrical systems. Connecting the transmitter to a bare conductor with the included alligator clips and test leads will always provide the most accurate results. However, in situations where a direct connection to a bare conductor is not available, the included i400 AC Current Clamp can be used with the “Loop” mode to induce a boosted 6 kHz signal through the insulation. The kit also includes batteries and a hard carrying case.

 

isswww and Fluke Instruments 

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software. 

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products. 

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, meteorologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities. 

Fluke are a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. We have Fluke trained staff on site and we hold an extensive range of their products. Our customers know that when it comes to Fluke products, we have not only the best prices but the best advice and support services, reassuring when you need to make that all-important purchase.  

 

 

Features & Specification

More Information
Key Features CAT IV 600V, Supplied With Case, Leads And Accessories, Trace circuits, MCB's and faults quickly, Test Lead Accessory Kit, Advanced wire tracer kit, Locate energized and de-energized wires, Non-contact voltage detection, Smart Sensor™ technology
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description
Fluke 2052 Advanced Wire Tracer Technical Specifications
  2052R Receiver 2000T Transmitter i400 AC Current Clamp
General
Measurement category CAT IV 600 V CAT IV 600 V CAT IV 600 V, CAT III 1000 V
Operating voltage 600 V AC/DC 600 V AC/DC 1000 V AC
Operating frequency Energized: 6.25 kHz
De-Energized: 32.768 kHz
Energized/Loop: 6.25 kHz
De-Energized: 32.768 kHz
N/A
Signal indications Numeric, bar graph display and audible beep LEDs and audible beep N/A
Response time Tip Sensor (Energized/ De-Energized): 500 ms
NCV: 500 ms
Battery monitoring: 5 s
Line voltage monitoring: 1 s Battery voltage monitoring: 5 s N/A
Current output
of signal (typical)
N/A Energized circuit:
High mode: 60 mA rms Low mode: 30 mA rms
De-energized circuit:
High mode: 110 mA rms Low mode: 40 mA rms
Loop mode with test leads: 160 mA rms
Loop mode with i400 AC Current Clamp: 385 mA rms
N/A
Signal voltage output (nominal) N/A Energized circuit:
High mode: 14 W @ 230 V ac/50 Hz,
3.33 kΩ @ 230 V ac
Low mode: 4.6 W @ 230 V ac/50 Hz,
11.5 kΩ @ 230 V ac
De-energized circuit:
High mode: 31 V RMS, 140 Vp-p,
0.86 W @ 1 kΩ load
Low mode: 27.5 V RMS, 120 Vp-p,
0.1 W @ 1 kΩ load
Loop mode with test leads: 32 V RMS, 140 Vp-p, 0.87 W @ 1 kΩ load
Loop mode with i400 AC Current Clamp: 31 mV, 0.89 W @ 1 Ω load
N/A
Range detection (open air) Tip Sensor: Energized
Max distance via air: up to 6.1 m (20 ft) Pinpointing: approx. 5 cm (1.97 in)
Tip Sensor: De-Energized
Max distance via air: up to 4.5 m (14.7 ft) Pinpointing: approx. 5 cm (1.97 in)
NCV (40 Hz to 400 Hz)
Max. sensitivity: 90 V up to 2 m Min. sensitivity: 600 V up to 1 cm
N/A N/A
Current range N/A N/A 400 A
Basic accuracy N/A N/A 2 % + 0.06 A
(45 Hz to 400 Hz)
  2052R Receiver 2000T Transmitter i400 AC Current Clamp
Display
Display size LCD 63 mm (2.5 in) LEDs N/A
Display dimensions (W x H) 37 mm x 49 mm (1.45 x 1.93 in) N/A N/A
Display Resolution 240 px x 320 px N/A N/A
Display type TFT LCD LEDs N/A
Display color 16-bit Operating mode LEDs: red
Battery status LEDs: green, yellow, red
N/A
Backlight Yes N/A N/A
Environmental
Operating temperature -20 °C to 50 °C
(-4 °F to 122 °F)
-20 °C to 50 °C
(-4 °F to 122 °F)
-20 °C to 50 °C
(-4 °F to 122 °F)
Operating humidity 45%: -20 °C to <10 °C or 40 °C to 50 °C
(-4 °F to <50 °F or 104 °F to 122 °F)
95% (non-condensing): 10 °C to <30 °C
(50 °F to 86 °F)
75%: 30 °C to <40 °C (86 °F to <104 °F)
45%: -20 °C to <10 °C or 40 °C to 50 °C
(-4 °F to <50 °F or 104 °F to 122 °F)
95% (non-condensing): 10 °C to <30 °C
(50 °F to 86 °F)
75%: 30 °C to <40 °C (86 °F to <104 °F)
10 °C to <30 °C
(95%: 50 °F to <86 °F)
30 °C to <40 °C
(75%: 86 °F to <104 °F)
40 °C to <50 °C
(45%: 104 °F to <122 °F)
Operating altitude 2000 m (6561 ft) 2000 m (6561 ft) 2000 m (6561 ft)
Transient protection N/A 8.00 kV (1.2/50μS surge) N/A
Pollution degree 2 2 2
IP rating IP 40 IP 40 IP 40
Drop test 1 m (3.28 ft) 1 m (3.28 ft) 1 m (3.28 ft)
Mechanical
Power supply 4 x AA (alkaline) 8 x AA (alkaline) N/A
Power consumption (typical) 110 mA High/low mode: 70 mA
Loop mode with Clamp: 90 mA
Consumption without signal transmission: 10 mA
N/A
Battery life Approx. 16 h High/low mode: approx. 25 h Loop mode: approx. 18 h N/A
Low battery indication Yes Yes N/A
Fuse N/A 1.6 A, 700 V, fast-acting,
Ø 6 x 32 mm, 50 kA interrupt
N/A
Maximum conductor size N/A N/A 32 mm (1.26 in)
Dimensions (L x W x H) Approx. 183 x 75 x 43 mm
(7.2 x 2.95 x 1.69 in)
Approx. 183 x 93 x 50 mm
(7.2 x 3.66 x 1.97 in)
Approx. 150 x 70 x 30 mm
(5.9 x 2.75 x 1.18 in)
Weight Approx.  0.27 kg (0.6 lb) Approx.  0.57 kg (1.25 lb) Approx.  0.114 kg (0.25 lb)
General
Includes 2x 1 m Test leads (red, black), 1x 7 m Test lead (green) 2x Test probes (black), 2x Alligator clips (red, black)
2x Outlet blade adapters (red, black), 2x Outlet round adapters (red, black)
Measurement category CAT IV 600 V (test leads), CAT II 1000 V (test probes), CAT IV 600 V (alligator clips), CAT II 300 V (outlet adapters)
Operating voltage and current 600 V, 10 A max. (red/black leads), 600 V, 10 A max. (green lead), 1000 V, 8 A max. (black probe) 600 V, 10 A max. (alligator clips), 300 V, 10 A max. (outlet adapters)
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Operating humidity 10 °C to <30 °C (95 %: 50 °F to <86 °F), 30 °C to <40 °C (75 %: 86 °F to <104 °F),
40 °C to <50 °C (45 %: 104 °F to <122 °F)
Storage temperature and humidity 0 °C to 60 °C (32 °F to 140 °F), <95 % (non-condensing)
Operating altitude 2000 m (6561 ft)
Pollution degree 2
Water and dust resistance IP 20
Drop proof 1 m (3.28 ft)
Dimensions Red/black leads: 1 m (3.28 ft), Green lead: 7 m (22.97 ft), Alligator clips: approx. 95 x 45 x 24 mm (3.74 x 1.77 x 0.94 in),
Outlet adapters: 72 x 18 x 18 mm (2.83 x 0.71 x 0.71 in)
Weight Approx. 0.4 kg (0.88 lb)

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA