Specifications
Voltage DC Accuracy1 ±(0.09% + 2)
Max. resolution 0.1 mV
Maximum 1000 V
Voltage AC Accuracy1 ±(1.0% + 3)
Max. resolution 0.1 mV
Maximum 1000 V
Current DC Accuracy1 ±(1.0% + 3)
Max. resolution 0.01 mA
Maximum 10 A
Current AC Accuracy1 ±(1.5% + 3)
Max. resolution 0.01 mA
Maximum 10 A
Resistance Accuracy1 ±(0.9% + 1)
Max. resolution 0.1 Ω
Maximum 50 MΩ
Capacitance Accuracy1 ±(1.2% + 2)
Max. resolution 1 nF
Maximum 10,000 µF
Frequency Accuracy1 ±(0.1% + 1)
Max. resolution 0.01 Hz
Maximum 100 kHz
Temperature Accuracy1 ±(1.0% + 10)
Max. resolution 0.1°C
Range -40°C / 400°C
1. Accuracies are best accuracies for each function
Environmental Specifications
Operating temperature -10°C to +50°C
Storage temperature -30°C to +60°C
Humidity (without condensation) 0% – 90% (0°C – 35°C)
0% – 70% (35°C – 50°C)
Safety Specifications
Overvoltage category EN 61010–1 to 1000 V CAT III
EN 61010–1 to 600 V CAT IV
Agency approvals UL, CSA, TÜV listed and VDE Pending
Mechanical and General Specifications
Size 43 x 90 x 185 mm
Weight 420 g
Warranty Lifetime
Battery life Alkaline ~200 hours typical, without backlight

Description

Fluke 179/ EDA2 TRMS Multimeter Kit

I Want No Other Meter in My Toolkit

With its precision, reliability, and ease of use, the Fluke 179 True RMS Digital Multimeter is the preferred solution for professional technicians around the world. With all the features you need to troubleshoot and repair in electrical and electronic systems, the Fluke 179 also offers a digital display with analog bar graph and built-in temperature measurements.

Works When You Need It, Where You Need It

You can trust the Fluke 179 to get the job done in all of the messy, loud, high energy and high places you work. Backed by a lifetime warranty, the Fluke 179 is independently tested for safe use in CAT IV 600 V/CAT III 1000 V environments.

The Fluke 179 – Just One of Fluke's Trusted Tools

Fluke builds the most trusted tools in the world, and that means more than just the Fluke 179. If you work with the HVAC equipment, need a small meter for small spaces, or work in the electrical installer's and repairman's world, check out the full family of Fluke digital multimeters.

  • Manual and automatic ranging
  • Display Hold and Auto Hold
  • Frequency and capacitance measurements
  • Resistance, continuity and diode measurements
  • Temperature measurements (179)
  • Min-max-average recording
  • Closed case calibration through front panel
  • Ergonomic case with integrated protective holster

Rugged 1000 V CAT III Fluke-179 multimeter with industrial strength test lead probe kit in a compact lightweight soft case.

Fluke 179/EDA 2 Includes:

  • Fluke 179
  • AC220 SureGrip™
  • Alligator Clips TP220 SureGrip™
  • Test Probes, TL224 SureGrip™
  • Silicone Test Leads
  • ToolPak magnetic meter-hanger.
  • Limited lifetime warranty on the multimeter, 1-year on all accessories

Features & Specification

More Information
Key Features Soft case, Test leads included, Temperature probe included
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description
Specifications
Voltage DC Accuracy1 ±(0.09% + 2)
Max. resolution 0.1 mV
Maximum 1000 V
Voltage AC Accuracy1 ±(1.0% + 3)
Max. resolution 0.1 mV
Maximum 1000 V
Current DC Accuracy1 ±(1.0% + 3)
Max. resolution 0.01 mA
Maximum 10 A
Current AC Accuracy1 ±(1.5% + 3)
Max. resolution 0.01 mA
Maximum 10 A
Resistance Accuracy1 ±(0.9% + 1)
Max. resolution 0.1 Ω
Maximum 50 MΩ
Capacitance Accuracy1 ±(1.2% + 2)
Max. resolution 1 nF
Maximum 10,000 µF
Frequency Accuracy1 ±(0.1% + 1)
Max. resolution 0.01 Hz
Maximum 100 kHz
Temperature Accuracy1 ±(1.0% + 10)
Max. resolution 0.1°C
Range -40°C / 400°C
1. Accuracies are best accuracies for each function
Environmental Specifications
Operating temperature -10°C to +50°C
Storage temperature -30°C to +60°C
Humidity (without condensation) 0% – 90% (0°C – 35°C)
0% – 70% (35°C – 50°C)
Safety Specifications
Overvoltage category EN 61010–1 to 1000 V CAT III
EN 61010–1 to 600 V CAT IV
Agency approvals UL, CSA, TÜV listed and VDE Pending
Mechanical and General Specifications
Size 43 x 90 x 185 mm
Weight 420 g
Warranty Lifetime
Battery life Alkaline ~200 hours typical, without backlight

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA