General Specifications              
Specification Characteristic            
Size 26.25 cm x 14.19 cm x 11.93 cm (10.3 in x 5.6 in x 4.7 in)            
Weight (incl.batteries) 1.6 kg (3.5 lb)            
Battery size, quantity BP290, Li-ion, 10.8 V, 2500 mAh, 27 Wh            
Ingress Protection IEC 60529: IP40            
Safety Complies with IEC/EN 61010-1, IEC 61010-2-030, IEC 61010-2-034            
Safety Rating CAT III 600 V, CAT IV 300 V            
Performance IEC 61557-1 to IEC/EN 61557-8 and IEC 61557-10            
Voltage measurement AC, DC, and frequency            
Range Resolution Input Impedance Overload Protection        
600v 0.1v 320kΩ 660v        
45-66 Hz 0.1 Hz 320kΩ -        
Continuity testing (RLO)              
Range (Auto ranging) Resolution Open Circuit Voltage          
20 Ω/200 Ω/2000 Ω 0.01 Ω/0.1 Ω/1 Ω >4v          
Insulation resistance measurement (RISO)            
Test Voltages              
1672 100-250-500-1000 V            
1673FC/1674FC 50-100-250-500-1000 V            
Test Voltage Insulation Resistance Range Resolution Test Current        
50v 10 kΩ to 50 MΩ 0.01 MΩ 1 mA @ 50 kΩ        
100v 10 kΩ to 20 MΩ 0.01 MΩ 1 mA @ 100 kΩ        
20 MΩ to 100 MΩ 0.1 MΩ        
250v 10 kΩ to 20 MΩ 0.1 MΩ 1 mA @ 250 kΩ        
20 MΩ to 200 MΩ 0.1 MΩ        
500v 10 kΩ to 20 MΩ 0.1 MΩ          
20 MΩ to 200 MΩ 0.1 MΩ 1 mA @ 500 kΩ        
200 MΩ to 500 MΩ 0.1 MΩ          
1000v 100 kΩ to 200 MΩ 0.1 MΩ 1 mA @ 1 MΩ        
200 MΩ to 1000 MΩ 1 MΩ        
Insulation pretest (1674 FC ONLY)            
Insulation safety pretest Connections from the Tester to L, N, and PE are required.            
Surge Protection Device (SPD) Insulation RAMP Test (Varistor Test) IEC 61643-11          
Test Voltages Voltage Ranges Resolution Test Current Accuracy      
500v Step Ramp 0 V to 500 V 1 v 1 mA ± (1.5 % + 3 digits)      
1000v Step Ramp 0 V to 1000 V 1 v 1 mA ± (1.5 % + 3 digits)      
Insulation Monitoring Devices (IMD) IEC 61557-8            
Range Resolution Note          
1 kΩ to 10 kΩ 1 kΩ            
10 kΩ to 100 kΩ 10 kΩ 1 MΩ only availablewith voltages >100 V          
100 kΩ to 3 MΩ 100 kΩ            
Loop and line impedance (ZI No Trip and Hi Current)            
Range Setting Resolution Accuracy[1]          
10 Ω[2] 0.001 Ω Hi Current mΩ mode: ± (2 % + 35 digits)          
  No Trip (2&3 wire) mode: ± (3 % + 6 digits)          
20 Ω 0.01 Ω Hi Current mode: ± (2 % + 4 digits)          
200 Ω 0.1 Ω No Trip mode: ± (3 %)          
  Hi Current mode: ± (2 %)          
2000 Ω 1 Ω ± 6 %[3]          
[1]Valid for resistance of neutral circuit < 20 Ω and up to a system phase angle of 30°. Test leads must be zeroed before testing.
[2]Fluke Connect™ 1674 FC model only.
[3]Valid for mains voltage > 200 V.
Prospective Earth Fault Current (PEFC) Prospective Short Circuit Current (PSC)            
Range Range Resolution          
0 kA to 50 kA IK < 1000 A 1:00 AM          
IK ≥ 1000 A 0.1 kA          
Computation: Prospective Earth Fault Current (PEFC/IK) or prospective short circuit current (psc/IK) determined by dividing
measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
Voltage drop (by line impedance test)            
Range Resolution Accuracy          
0.0-99.9% 0.10% Consider accuracy of line          
impedance measurement(s)          
Note: Voltage drop reading is calculated from line impedance measurement & entered current rating
RCD tests, RCD types tested            
RCD Type[1]   1672 1673 FC 1674 FC      
AC[2] G[3]      
AC S[4]      
A[5], F[6] G      
A,F S      
B, B+[7] G        
B, B+ S        
RDC-DD, RCD A/EV, RCD B/Mi[8]        
GFCI            
[1]RCD test inhibited for V > 265 AC
[2]RCD tests permitted only if the selected current, multiplied by earthing resistance, is < 50 V.
[3]AC – Responds to AC
[4]G – General, no delay
[5]S – Time delay
[6]A – Responds to AC and pulsed signal
[7]F – responds to AC, pulsed and high frequency
[8]B, B+ – Responds to AC, pulsed, high frequency, and smooth DC
[9]RDC-DD – Responds to residual currents of 6 mA DC
RCD tripping time test (ΔT)            
Test Function RCD Current Selection
10mA 30mA 100mA[1] 300mA[1] 500mA[1] 1000mA[2] Var[3]
X 1/2, 1
X5        
Ramp
Auto        

Mains voltage 50 V – 265 V ac, 45/66 Hz
[1]Type B RCDs require mains voltage range of 195 V to 265 V
[2]Type AC RCDs only.
[3]Type A RCDs are limited to 700 mA, not available for Type B RCDs.

RCD Tripping Current (IΔN) Measurement/Ramp Test
Current Range Step Size Dwell Time Type G Dwell Time Type S Measurement Accuracy
30% to 110% of RCD-rated current[1] 10 % of IΔN [2] 300MS/STEP 500 MS/STEP ± 5 %
[1] Specified trip current ranges (IEC 61008-1):
30 % to 150 % for Type A IΔ N > 10 mA
30 % to 210 % for Type A IΔ N = 10 mA
20 % to 210 % for Type B
50 % to 100 % for Type AC
35 % to 140 % for Type A (> 10 mA)
35 % to 200 % for Type A (≤ 10 mA)
50 % to 200 % for Type B
[2] 5 % for Type B
 
Earth resistance test (RE) 1673 FC and 1674 FC only
Range Resolution Frequency Output Voltage        
200 Ω/2000 Ω 0.1 Ω/1 Ω 128 Hz 25 V        
Phase sequence indication
Icon  Range Display          
Phase Sequence indicator is active 185 V to 600 V “1-2-3”: or “3-2-1” for incorrect phase        
IMMEDIATE DISPATCH

Description

Fluke 1672 Multifunction Installation Tester 5580852

A single solution for all your installation testing needs. Simplified setup, faster testing and easier reporting.

*Important Calibration Information: 

This instrument comes complete with the manufacturer’s calibration certificate. Please be aware that these certificates are generic and may also be time-lapsed. If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply. 

 

In a hurry and just looking for the facts?

Please see our 1670 series selector at the foot of this page for all the specification comparisons at a glance.

The Fluke 1670 Series Multifunction Installation Testers will revolutionize the way you work. With an ergonomic design, seamless user interface, integrated data management capabilities, wireless connectivity (1673 FC and 1674 FC), and comprehensive reporting software, the 1670 Series sets the new standard for an integrated installation testing solution.
Reliable installation testing is essential for ensuring the safety, optimal functionality, and integrity of a facility’s electrical systems.
The 1670 Series' rugged design allows you to verify the safety of electrical installations in domestic, commercial, and industrial applications while meeting the requirements of IEC/HD 60364-6 and all relevant local installation test standards.
With the 1670 Series, you’ll be able to perform your required testing faster and reduce the time you spend on documentation, all while having the ultimate confidence in the data you’re collecting.

Intuitive user interface and setup

Streamlined user interface eliminates complex multi-level menus for easy setup with the full-colour touch screen, your smart device, or a PC, so you get the most out of your time on site.

Fast, accurate testing

Accelerate installation testing accuracy and efficiency with Auto Test and Automatic Measurement Validation functions.

Simplified reporting and results

Simplify report generation with automatic report population, Fluke Connect integration, and one-touch reporting with Fluke TruTest™ software.

 

 

Fluke 1672 Comes Supplied With:

  • Heavy duty mains cord with single input connector
  • Hard case
  • USB-C power adapter for charging
  • Remote control probe
  • Hanging strap
  • Zero adapter
  • Test leads and probes
  • Alligator clips
  • Li-Ion battery

Simplified User Interface and Testing Setup

The 1670 Series takes data management to the next level streamlining test set-up and preparation with an advanced bidirectional user interface. When setting up your project, the hierarchical tree topology for clients, sites, distribution boards, circuits, and test points can be easily customized using the high-resolution colour touchscreen, a smart device, or a PC.
Edit, add, delete, or modify information directly on the tool as you test to ensure accurate data, or transfer updates to your tester via the Fluke Connect™ mobile app or TruTest™ desktop software. Easy-to-read test tables help you quickly see that you are capturing the right measurement data at the right test point, every time. Now you can spend less time setting up your tester and organising data, giving you more time to perform valuable testing.

Perform All Required Tests up to 30% Faster

Installation testing can be a time-consuming process. It often requires repetitive, manual test setups that can be frustrating and introduce the opportunity for errors. The Fluke 1670 Series leverages a unique Auto Test function (1673 FC / 1674 FC) that enables you to run through an entire installation test sequence at the touch of a button.
An integrated help function provides a visual connection guide to help ensure measurement success. Automatic measurement validation, with user-defined limit warnings, compares test results to the relevant standards and provides you with an immediate visual pass/fail indication to quickly identify potential issues. Eliminating manual testing and automating measurement validation means you can perform your tests up to 30% faster than manual testing, giving you more time to focus on other critical tasks and increasing your productivity.

Key Features:

Reduce Documentation and Reporting Time up to 50%

The Fluke 1670 Series Multifunction Installation Testers help
you reduce documentation time by up to 50%. Link test results
to the circuit or point under test, reducing manual data entry
and recordkeeping. You can also preview inspection results in
the field via the tester, a smart device, or PC, and Fluke Connect
compatibility making it easy to store, manage, and share your
data from the field. Fluke TruTest Software lets you generate
inspection certificates on site with just a few simple steps,
so you can finalise and invoice your inspection at the time of
service. The Fluke Connect mobile app enables you to document
and input all relevant photos and inspection notes, so you can
complete your work on site, eliminating extra work at the office.
*50% faster reporting and documentation based on customer interviews.


Insulation Pre
Test™ Functionality (1674FC ONLY)

The Fluke 1674 FC includes a patented Insulation PreTest, so you
can better protect the installation and avoid costly mistakes. If
the tester detects that appliances are connected to the system
during the test, it will stop the insulation test and provide a
visual and audible warning. This helps eliminate accidental
damage to peripheral equipment and saves you both time and
money.

Optimized Software and Reporting

Fluke TruTest Software simplifies electrical system data
management and reporting, eliminating the hassle of traditional
data management with a single, integrated Fluke solution.
Proper data management and testing information is critical
for producing easy-to-understand reports for clients or your
management team. TruTest streamlines the process by allowing
you to create and transfer testing metadata between the
software and your installation tester using a USB-C interface
cable, or via the Fluke Connect mobile app, which helps you
ensure accurate results.
The user-friendly interface, intuitive workflow, and report
builder means that you can quickly format your measurement
data into printable test certificates and reports, complete with
your company logo and electronic signature. The live onscreen
dashboard allows you to see the status of all your clients instantly
and navigate to further levels of detail if desired.
Fluke TruTest Software allows you to create certificates that
are compliant with a growing list of regional reports, including
BS7671, DIN VDE 0100-600, ÖVE/ÖNORM E 8101, NIN/NIV,
NEN3140, and other European installation test standards. All
these reports are available at the touch of a button, and a
pre-configured international template ensures that no matter
your location, TruTest Software has you covered.

Additional Capabilities:

• Field updatable — you can apply any changes to regulations or enhancements to the tester in the field.
• Compact and lightweight (less than 1.6 kg), with a padded neck strap to free your hands.
• Full-color touch screen and tactile rotary knob for fast navigation, with no complex multi-level menus.
• Rechargeable 2,500 mAh Li-ion battery to cover a full day of testing.
• Standard USB-C charging Port with fast charging support for convenient on-the-go charging.
• Newly designed professional hard case for transporting and protecting your installation tester and accessories.
• Additional high current loop mode for faster measurements than loop tests with non-trip mode for RCD protected circuits.
• Voltage drop measurement function.

• Unique zero adapter for fast, reliable, and accurate test lead and mains cord compensation.
• Simultaneous readings of voltage measurements between L-N, L-PE, and N-PE using the mains cord. No need to change measurement connections.
• RCD trip current and trip time measurement in parallel (RCD type AC, A, B, F and GFCI).
• PEFC or PSC and loop impedance measurement in parallel, displays them together on the dual display.
• Ring testing lets you select the required input sockets without exchanging test leads.
• Continuity test with low test current (10 mA) to measure motor windings.
• Earth Volt Touchpad detects raised earth voltages >50 V, indicating potentially dangerous situations.

Which Fluke 1670 series tester is right for me?

Model

1662

1663FC

1664FC

1672

1673FC

1674FC

 New 167x series features

 Full-colour touch-screen

-

-

-

 Li-ion battery

-

-

-

 USB-C port supports charging & data transfer

-

-

-

 Digital rotary dial supports new feature additions

-

-

-

 Form capture

-

-

-

 Project setup

-

-

-

 Field updatable

-

-

-

 Bi-directional data

-

-

-

 660v maximum voltage, 600v operation

-

-

-

 Pass-Fail limits

-

-

-

 On-screen help

-

-

-

 Voltage drop measurement

-

-

-

 Insulation monitoring device (IMD) test

-

-

-

-

-

 Surge protection device (SPD) test

-

-

-

-

-

 Save results from other Fluke Connect tools

-

-

-

-

 User-programmable auto-test sequence

-

-

-

-

-

 Shared features between 166x and 176x

 Wiring polarity checker detects broken PE & N wires

 Insulation resistance

 Continuity and resistance

 Measure motor windings with continuity test   (@10mA)

 Loop and impedance

 Prospective earth fault current (PEFC/IK)

 Prospective short-circuit current (PSC/IK)

 RCD trip time / RCD trip current (ramp test)

 Measures trip time and current for RCD type AC, A,   and F in one test

 RCD variable test current

 Automatic RCD test sequence

 Phase sequence test

 Voltage AC, DC and frequency

 

 Insulation at L-N, L-PE, N-PE inputs

250v, 500v, 1000v

50v, 100v, 250v, 500v, 1000v

250v, 500v, 1000v

250v, 500v, 1000v

250v, 500v, 1000v

50v, 100v, 250v, 500v, 1000v

 Continuity at L-N, L-PE, N-PE inputs

-

 EV test 6mA DC (RCD A/EV, RCD B/Mi, RCD-DD)

-

-

 Earth resistance

-

-

 Standard auto-test sequence

-

-

-

 Insulation PreTest™ safety function

-

-

-

 

 Loop and line impedance – mΩ resolution

-

-

-

 

 Auto pass/fail results

-

-

-

 Fluke Connect™ App compatibility

-

-

 Fluke Cloud™ storage

-

-

 On/Off switchable Auto-start for RCD and loop test

 USB-C / BLE

IR-USB

IR-USB/BLE

IR-USB/BLE

USB-C

USB/BLE

USB/BLE

 Memory

 Z Max memory

-

-

 

Fluke Connect

Preventive Maintenance Simplified

Save time and improve the reliability of your maintenance data by
wirelessly syncing measurements using the Fluke Connect system.
• Eliminate data-entry errors by saving measurements directly from the tool and associating them with the work order, report or asset record.

• Maximize uptime and make confident maintenance decisions with data you can trust and trace.

• Move away from clipboards, notebooks and multiple spreadsheets with a wireless one-step measurement transfer.

• Access baseline, historical and current measurements by asset.
• Share your measurement data using ShareLive™ video calls and emails.

            Visit the Fluke website to learn more about the
                               Fluke Connect system

     

Reduce unplanned expenses and get the most out of your tools with Fluke Premium Care


When you invest in the best equipment in the industry, you want your money to go as far as possible.
Fluke Premium Care provides coverage above and beyond your tool’s original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair. Fluke Premium Care Standard is available with one-year or three-year plan options so you can choose the plan that is right for you.

  Standard Warranty Premium Care Standard
Repair manufacturing defects                                    •                                     •
Accidental damage and repair                                       •
Replacement of damaged accessories                                       •
Annual calibration or performance check                                       •
Expedited calibration and repair                                       •
Priority tech support                                       •
Software updates                                       •
Expedited shipping                                       •

Learn more about Fluke Premium Care support website.

isswww and Fluke Instruments 

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software.  

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.  

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep business and industry around the globe up and running. Typical customers and users include technicians, engineers, meteorologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.  

Fluke are a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. We have Fluke trained staff on site and we hold an extensive range of their products. Our customers know that when it comes to Fluke products, we have great prices and exceptional advice and support services, reassuring when you need to make that all-important purchase. 

Features & Specification

More Information
Key Features Easy to use rotary dial, The very latest multifunction tester technology, Field updatable, Remote control for passive tests, Voltage drop measurement function, RCD trip current (RCD type AC A B F and GFCI), Continuity test with low test current (10 mA), PEFC or PSC and loop impedance
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description
General Specifications              
Specification Characteristic            
Size 26.25 cm x 14.19 cm x 11.93 cm (10.3 in x 5.6 in x 4.7 in)            
Weight (incl.batteries) 1.6 kg (3.5 lb)            
Battery size, quantity BP290, Li-ion, 10.8 V, 2500 mAh, 27 Wh            
Ingress Protection IEC 60529: IP40            
Safety Complies with IEC/EN 61010-1, IEC 61010-2-030, IEC 61010-2-034            
Safety Rating CAT III 600 V, CAT IV 300 V            
Performance IEC 61557-1 to IEC/EN 61557-8 and IEC 61557-10            
Voltage measurement AC, DC, and frequency            
Range Resolution Input Impedance Overload Protection        
600v 0.1v 320kΩ 660v        
45-66 Hz 0.1 Hz 320kΩ -        
Continuity testing (RLO)              
Range (Auto ranging) Resolution Open Circuit Voltage          
20 Ω/200 Ω/2000 Ω 0.01 Ω/0.1 Ω/1 Ω >4v          
Insulation resistance measurement (RISO)            
Test Voltages              
1672 100-250-500-1000 V            
1673FC/1674FC 50-100-250-500-1000 V            
Test Voltage Insulation Resistance Range Resolution Test Current        
50v 10 kΩ to 50 MΩ 0.01 MΩ 1 mA @ 50 kΩ        
100v 10 kΩ to 20 MΩ 0.01 MΩ 1 mA @ 100 kΩ        
20 MΩ to 100 MΩ 0.1 MΩ        
250v 10 kΩ to 20 MΩ 0.1 MΩ 1 mA @ 250 kΩ        
20 MΩ to 200 MΩ 0.1 MΩ        
500v 10 kΩ to 20 MΩ 0.1 MΩ          
20 MΩ to 200 MΩ 0.1 MΩ 1 mA @ 500 kΩ        
200 MΩ to 500 MΩ 0.1 MΩ          
1000v 100 kΩ to 200 MΩ 0.1 MΩ 1 mA @ 1 MΩ        
200 MΩ to 1000 MΩ 1 MΩ        
Insulation pretest (1674 FC ONLY)            
Insulation safety pretest Connections from the Tester to L, N, and PE are required.            
Surge Protection Device (SPD) Insulation RAMP Test (Varistor Test) IEC 61643-11          
Test Voltages Voltage Ranges Resolution Test Current Accuracy      
500v Step Ramp 0 V to 500 V 1 v 1 mA ± (1.5 % + 3 digits)      
1000v Step Ramp 0 V to 1000 V 1 v 1 mA ± (1.5 % + 3 digits)      
Insulation Monitoring Devices (IMD) IEC 61557-8            
Range Resolution Note          
1 kΩ to 10 kΩ 1 kΩ            
10 kΩ to 100 kΩ 10 kΩ 1 MΩ only availablewith voltages >100 V          
100 kΩ to 3 MΩ 100 kΩ            
Loop and line impedance (ZI No Trip and Hi Current)            
Range Setting Resolution Accuracy[1]          
10 Ω[2] 0.001 Ω Hi Current mΩ mode: ± (2 % + 35 digits)          
  No Trip (2&3 wire) mode: ± (3 % + 6 digits)          
20 Ω 0.01 Ω Hi Current mode: ± (2 % + 4 digits)          
200 Ω 0.1 Ω No Trip mode: ± (3 %)          
  Hi Current mode: ± (2 %)          
2000 Ω 1 Ω ± 6 %[3]          
[1]Valid for resistance of neutral circuit < 20 Ω and up to a system phase angle of 30°. Test leads must be zeroed before testing.
[2]Fluke Connect™ 1674 FC model only.
[3]Valid for mains voltage > 200 V.
Prospective Earth Fault Current (PEFC) Prospective Short Circuit Current (PSC)            
Range Range Resolution          
0 kA to 50 kA IK < 1000 A 1:00 AM          
IK ≥ 1000 A 0.1 kA          
Computation: Prospective Earth Fault Current (PEFC/IK) or prospective short circuit current (psc/IK) determined by dividing
measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
Voltage drop (by line impedance test)            
Range Resolution Accuracy          
0.0-99.9% 0.10% Consider accuracy of line          
impedance measurement(s)          
Note: Voltage drop reading is calculated from line impedance measurement & entered current rating
RCD tests, RCD types tested            
RCD Type[1]   1672 1673 FC 1674 FC      
AC[2] G[3]      
AC S[4]      
A[5], F[6] G      
A,F S      
B, B+[7] G        
B, B+ S        
RDC-DD, RCD A/EV, RCD B/Mi[8]        
GFCI            
[1]RCD test inhibited for V > 265 AC
[2]RCD tests permitted only if the selected current, multiplied by earthing resistance, is < 50 V.
[3]AC – Responds to AC
[4]G – General, no delay
[5]S – Time delay
[6]A – Responds to AC and pulsed signal
[7]F – responds to AC, pulsed and high frequency
[8]B, B+ – Responds to AC, pulsed, high frequency, and smooth DC
[9]RDC-DD – Responds to residual currents of 6 mA DC
RCD tripping time test (ΔT)            
Test Function RCD Current Selection
10mA 30mA 100mA[1] 300mA[1] 500mA[1] 1000mA[2] Var[3]
X 1/2, 1
X5        
Ramp
Auto        

Mains voltage 50 V – 265 V ac, 45/66 Hz
[1]Type B RCDs require mains voltage range of 195 V to 265 V
[2]Type AC RCDs only.
[3]Type A RCDs are limited to 700 mA, not available for Type B RCDs.

RCD Tripping Current (IΔN) Measurement/Ramp Test
Current Range Step Size Dwell Time Type G Dwell Time Type S Measurement Accuracy
30% to 110% of RCD-rated current[1] 10 % of IΔN [2] 300MS/STEP 500 MS/STEP ± 5 %
[1] Specified trip current ranges (IEC 61008-1):
30 % to 150 % for Type A IΔ N > 10 mA
30 % to 210 % for Type A IΔ N = 10 mA
20 % to 210 % for Type B
50 % to 100 % for Type AC
35 % to 140 % for Type A (> 10 mA)
35 % to 200 % for Type A (≤ 10 mA)
50 % to 200 % for Type B
[2] 5 % for Type B
 
Earth resistance test (RE) 1673 FC and 1674 FC only
Range Resolution Frequency Output Voltage        
200 Ω/2000 Ω 0.1 Ω/1 Ω 128 Hz 25 V        
Phase sequence indication
Icon  Range Display          
Phase Sequence indicator is active 185 V to 600 V “1-2-3”: or “3-2-1” for incorrect phase        

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA