AC voltage measurement
Range 500 V
Resolution 0.1 V
Accuracy 45 Hz – 66 Hz 0.8% + 3
Input impedance 360 kΩ
Overload protection 660 V rms
Continuity testing (RLO)
Range (autoranging) 20 Ω / 200 Ω / 2000 Ω
Resolution 0.01 Ω / 0.1 Ω / 1 Ω
Open Circuit Voltage >4 V
Insulation resistance measurement (RISO)
Test voltages 100-250-500-1000 V
Accuracy of tTest voltage (at rated test current) +10%, -0%
Test voltage 50 V
100 V
250 V
500 V
1000 V
Insulation resistance range 20 MΩ /50 MΩ
20 MΩ / 100 MΩ
20 MΩ / 200 MΩ
20 MΩ / 200 MΩ / 500 MΩ
20 MΩ / 200 MΩ / 1000 MΩ
Resolution 0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
Test current 1 mA @ 50 kΩ
1 mA @ 100 kΩ
1 mA @ 250 kΩ
1 mA @ 500 kΩ
1 mA @ 1 MΩ
Loop and line impedance (ZI)
Range 10 Ω / 0.001 Ω / High current mΩ mode
Resolution 0.01 Ω / 0.1 Ω / 1 Ω
Prospective earth fault current, PSC test
Range 1000 A / 10 kA (50 kA)
Resolution 1 A / 0.1 kA
Computation Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
RCD testing, RCD types tested
RCD Type AC¹
G²,S³
Model 1662 A4, AC¹, G²,S³
Notes ¹Responds to AC 
²General, no delay
³Time delay
4Responds to pulsed signal
5Responds to smooth DC signal
Tripping speed test (ΔT)
Current settings¹ 10-30-100-300-500-1000 mA – VAR
10-30-100 mA
Multiplier x ½, x 1
x 5
Measurement range RCD Type G 310 ms
50 ms
RCD Type S 510 ms
160 ms
Notes ¹1000 mA type AC only
700 mA maximum type A in VAR mode
VAR mode not available for type B.
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
Current range 30% to 110% of RCD rated current¹
Step size 10% of IΔN²
Dwell time Type G 300 ms/step
Type S 500 ms/step
Measurement accuracy ±5%
Specified trip current ranges (EN 61008-1) 50% to 100% for Type AC
35% to 140% for Type A (>10 mA)
35% to 200% for Type A (≤10 mA)
50% to 200% for Type B
²5% for Type B
Notes ¹30% to 150% for Type A IΔN > 10 mA
30% to 210% for Type A IΔN = 10 mA
20% to 210% for Type B
Phase Sequence Indication
Icon  Phase Sequence indicator is active.
General Specifications
Size (L x W x H) 10 x 25 x 12.5 cm
Weight (incl. batteries) 1.3 Kg
Battery size, quantity Type AA, 6 ea.
Sealing IP-40
Safety Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
Overvoltage CAT III / 500V; CAT IV 300V
Performance EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition
FREE Gift

Description

 

 

This instrument comes complete with your choice of free gift from the drop-down menu above. Choose from a calibration voucher for next 
year or a 50m R2 wander lead. How about any one of the IET Guidance Notes, or a quality two-pole tester? 
Whatever you choose you can be sure you're getting a fantastic deal at Instrument Sales & Service.

IMPORTANT
A new firmware is available for Fluke models 1663 and 1664 allowing the 6mA RCD trip test.
Please see the 6MA FW document in the Resources tab above for detailed instructions.
You are advised to read this document fully before updating your tester.

Fluke 1663 Multifunction Tester

Stock due November 2024

High Spec Multifunction Tester For Professionals

This instrument is ideal for professional users – full-featured functionality, advanced measurement capability, yet it is still easy to use. Operation is intuitive and easily mastered by all levels of field workers. The 1663 puts more power in your hands by quickly and efficiently testing to all local regulations, protecting appliances that may be inadvertently connected to the system under test, and making it easy to share test results over your smartphone.

*Calibration Options:

This instrument comes complete with a manufacturers calibration certificate. Please be aware that these certificates are generic and may also be time-lapsed. If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.

Fluke 1663 Multifunction Installation Tester Includes:

  • 6x AA (IEC LR6) cell batteries
  • C1600 hard carrying case
  • Zero adapter
  • Heavy-duty mains cord
  • STD standard test lead set
  • Padded carrying and waist strap
  • Quick reference guide
  • TP165X remote control probe and lead
  • User's manual on CD-ROM
  • FREE Traceable Calibration Certificate

 

The versatility of the Fluke Multifunction Tester

Insulation-continuity test: our installation tester does the job.
Fluke installation testers can be used to perform an insulation-continuity test, which is designed to diagnose and prevent the breakdown of the insulation in various parts of the electrical system such as wires, transformers and motors. The quality of insulation is critical to assure proper, uninterrupted and safe functioning of electrical circuits.

Checking RCD devices with a Fluke multifunction tester.
Our versatile installation testers can also check the proper functioning of residual-current devices (RCDs). RCDs are designed to disconnect quickly to mitigate the harm caused from electric shock and to avoid current leaks that may lead to fire and other dangerous situations. Our installation testers assure that RCDs can properly perform this important task.

The perfect loop testing tool: a Fluke installation tester.
Loop testing is a quick, convenient, and highly specific method of evaluating an electrical circuit for its ability to engage protective devices (circuit breakers, fuses, RCDs). A ground loop determines the effectiveness of protective devices.

Resistance measurement of grounding systems.
The electrical installation testing abilities of the Fluke installation tester also include verification tests to ensure that a system's resistance is low enough to provide protection to people, equipment and structures. A properly functioning grounding system is a critical safety feature of an electrical system.

Measurement functions

  • Continuity at L-N, N-PE inputs
  • Test smooth dc sensitive RCDs (Type B)
  • Earth resistance
  • Voltage & frequency
  • The wiring polarity checker detects broken N wires
  • Insulation resistance
  • Continuity & resistance
  • Measure motor windings with continuity test
  • Loop & line resistance
  • Prospective earth fault current (PEFC/IK)
  • Prospective short-circuit current (PSC/IK)
  • RCD switching time
  • RCD tripping level (ramp test)
  • Measures trip time & current for RCD type A & AC in one test
  • RCD variable current
  • Automatic RCD test sequence
  • Phase sequence indicator

Other features

  • On/Off switchable auto-start for RCD & loop test
  • Self-test
  • Illuminated display

Memory interface

  • Z Max Memory
  • Memory
  • Computer Interface (when used with optional FlukeView & Fluke DMS software)
  • Time and date (when used with optional FlukeView software)

Fluke 1660 Series Comparison Guide

Which is the right model for me?

The new Fluke 1660 Series Multifunction Installation Testers are the only installation testers that help prevent damage to connected appliances while allowing users to wirelessly e-mail results from the field. Auto Test does all required installation tests in one sequence, ensuring compliance with local installation regulations.

 

Measurement Function

1664 FC

1663

1662

Insulation-PreTest™ safety function New

*

 

 

Insulation at L-N, N-PE and L-PE inputs New

*

 

 

Automatic test sequence New

*

 

 

Loop and line resistance–mΩ resolution

*

 

 

Continuity at L-N, N-PE and L-PE inputs New

*

*

 

Test smooth dc sensitive RCDs (Type B)

*

*

 

Earth resistance

*

*

 

Voltage (True-rms) and frequency

*

*

*

Wiring polarity checker, detects broken PE and N wires

*

*

*

Insulation resistance Continuity and resistance

*

*

*

Measure motor windings with continuity test (@ 10 mA)

*

*

*

Loop and line resistance

*

*

*

Prospective earth fault current (PEFC/IK)

*

*

*

Prospective short-circuit current (PSC/IK

*

*

*

RCD switching time 

*

*

*

RCD trip time 

*

*

*

RCD trip current (ramp test)

*

*

*

 Measures trip time and current for RCD type A & ac in one test

*

*

*

RCD variable test current

*

*

*

Automatic RCD test sequence

*

*

*

Phase sequence test  

*

*

*

Other features

 

 

 

Fluke Connect Compatibility New     

*

 

 

ShareLive™ Calling New 

*

 

 

FlukeCloud™ Storage New

*

 

 

On/Off switchable auto-start for RCD and loop test New

*

*

*

Self-test 

*

*

*

Illuminated display       

*

*

*

Memory, interface

 

 

 

Z max memory New 

*

*

 

Memory

*

*

 

IR-USB and BLE interface (use with optional Fluke DMS and FVF software)

IR-USB/BLE

IR-USB

 

Included accessories

 

 

 

Heavy duty, single input line cord New

*

*

*

Hard case

*

*

*

Remote control probe

*

*

*

Zero adapter

*

*

*


isswww and Fluke Instruments

Fluke Corporation is the world leader in the manufacture, distribution and service of electronic test tools and software.

Since its founding in 1948, Fluke has helped define and grow a unique technology market, providing testing and troubleshooting capabilities that have grown to mission-critical status in manufacturing and service industries. Every new manufacturing plant, office, hospital, or facility built today represents another potential customer for Fluke products.

From industrial electronic installation, maintenance and service, to precision measurement and quality control, Fluke tools help keep businesses and industries around the globe up and running. Typical customers and users include technicians, engineers, meteorologists, medical-device manufacturers, and computer network professionals, people who stake their reputations on their tools, and use tools to help extend their personal power and abilities.

Fluke is a founding core supplier of ISSWWW and we enjoy a personal and professional relationship with them. Our sales staff and our technicians are Fluke trained and we hold perhaps the largest stock of their products in the country. Our customers know that when it comes to Fluke products, we have not only the best prices but the best advice and support services, reassuring when you need to make that all-important purchase.

Features & Specification

More Information
Key Features Manufacturers Calibration Certificate, Phase Rotation Service, Earth Testing, Downloadable, Auto RCD, Backlit LCD Display, Non Trip Loop Testing, Memory Function
Product Stock Status Product is currently unavailable – Click Here for related products
Manufacturer Fluke Testers
Short Description
AC voltage measurement
Range 500 V
Resolution 0.1 V
Accuracy 45 Hz – 66 Hz 0.8% + 3
Input impedance 360 kΩ
Overload protection 660 V rms
Continuity testing (RLO)
Range (autoranging) 20 Ω / 200 Ω / 2000 Ω
Resolution 0.01 Ω / 0.1 Ω / 1 Ω
Open Circuit Voltage >4 V
Insulation resistance measurement (RISO)
Test voltages 100-250-500-1000 V
Accuracy of tTest voltage (at rated test current) +10%, -0%
Test voltage 50 V
100 V
250 V
500 V
1000 V
Insulation resistance range 20 MΩ /50 MΩ
20 MΩ / 100 MΩ
20 MΩ / 200 MΩ
20 MΩ / 200 MΩ / 500 MΩ
20 MΩ / 200 MΩ / 1000 MΩ
Resolution 0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
Test current 1 mA @ 50 kΩ
1 mA @ 100 kΩ
1 mA @ 250 kΩ
1 mA @ 500 kΩ
1 mA @ 1 MΩ
Loop and line impedance (ZI)
Range 10 Ω / 0.001 Ω / High current mΩ mode
Resolution 0.01 Ω / 0.1 Ω / 1 Ω
Prospective earth fault current, PSC test
Range 1000 A / 10 kA (50 kA)
Resolution 1 A / 0.1 kA
Computation Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
RCD testing, RCD types tested
RCD Type AC¹
G²,S³
Model 1662 A4, AC¹, G²,S³
Notes ¹Responds to AC 
²General, no delay
³Time delay
4Responds to pulsed signal
5Responds to smooth DC signal
Tripping speed test (ΔT)
Current settings¹ 10-30-100-300-500-1000 mA – VAR
10-30-100 mA
Multiplier x ½, x 1
x 5
Measurement range RCD Type G 310 ms
50 ms
RCD Type S 510 ms
160 ms
Notes ¹1000 mA type AC only
700 mA maximum type A in VAR mode
VAR mode not available for type B.
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
Current range 30% to 110% of RCD rated current¹
Step size 10% of IΔN²
Dwell time Type G 300 ms/step
Type S 500 ms/step
Measurement accuracy ±5%
Specified trip current ranges (EN 61008-1) 50% to 100% for Type AC
35% to 140% for Type A (>10 mA)
35% to 200% for Type A (≤10 mA)
50% to 200% for Type B
²5% for Type B
Notes ¹30% to 150% for Type A IΔN > 10 mA
30% to 210% for Type A IΔN = 10 mA
20% to 210% for Type B
Phase Sequence Indication
Icon  Phase Sequence indicator is active.
General Specifications
Size (L x W x H) 10 x 25 x 12.5 cm
Weight (incl. batteries) 1.3 Kg
Battery size, quantity Type AA, 6 ea.
Sealing IP-40
Safety Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
Overvoltage CAT III / 500V; CAT IV 300V
Performance EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA