Fluke 116 Multimeter 62 Max+ IR Thermometer HVAC Kit

£382.50

 

Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 °C to + 50 °C
Storage Temperature -40 °C to + 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight

 

Accuracy Specifications
DC millivolts Range 600.0 mV
Resolution 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range 600.0 V
Resolution 0.1 V
Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms Range 600.0 mV
Resolution 0.1 mV
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.0 V / 0.1 V
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range 600 Ω
Resolution 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms Range/Resolution 600.0 Ω / 0.1 Ω
Range/Resolution 6.000 kΩ / 0.001 kΩ
Range/Resolution 60.00 kΩ / 0.01 kΩ
Range/Resolution 600.0 kΩ / 0.1 kΩ
Range/Resolution 6.000 MΩ / 0.001 MΩ
Accuracy 0.9 % + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 1.5 % + 2
Diode Test Range/Resolution  2.000 V / 0.001 V
Accuracy  0.9% + 2
Capacitance Range/Resolution 1000 nF / 1 nF
Range/Resolution 10.00 μF / 0.01 μF
Range/Resolution 100.0 μF / 0.1 μF
Range/Resolution 9999 μF / 1 μF
Range/Resolution 100 μF to 1000 μF
Accuracy 1.9% + 2
Range/Resolution > 1000 μF
Accuracy 5% + 20%
LoZ capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
Temperature2 (Type-K thermocouple) Range/Resolution -40 °C to 400 °C / 0.1 °C
Accuracy 1% + 102
Range/Resolution -40 °F to 752 °F / 0.2 °F
Accuracy 1% + 182
AC μamps true-rms (45 Hz to 500 Hz) Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
DC μamps Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
Hz (V or A input)2 Range/Resolution 99.99 Hz / 0.01 Hz
Range/Resolution 999.99 Hz / 0.1 Hz
Range/Resolution 9.999 Hz / 0.001 Hz
Range/Resolution 50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

 

Mechanical & General Specifications
Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight 550 g
Warranty 3 years

 

Fluke 62 MAX+ Infrared Thermometer

 

Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62+ MAX <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability of Readings ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II

Description

Fluke 116 and 62 Max + Technician's Combo Kit

For Every HVAC professional


For the complete solution to HVAC troubleshooting the extra value-packed HVAC Technician’s Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.

 

Fluke116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.

  • Fluke 116 HVAC Multimeter with Temperature and Microamps.
  • TL175 Hard Point Test Lead Set.
  • TPak ToolPak Magnetic Meter Hanging Strap.
  • Flexible Cuff Pipe Clamp Thermocouple.
  • 80BK Integrated Temperature Probe.
  • 80AK-A Thermocouple Adapter.
  • C115 Deluxe Soft Carrying Case with Shoulder Strap.
 

Fluke 62 MAX+. Small in size. Big on toughness.

  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.

Features & Specification

More Information
Key Features Soft case, Test leads included, Temperature probe included
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Fluke Testers
Short Description

 

Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 °C to + 50 °C
Storage Temperature -40 °C to + 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight

 

Accuracy Specifications
DC millivolts Range 600.0 mV
Resolution 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range 600.0 V
Resolution 0.1 V
Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms Range 600.0 mV
Resolution 0.1 mV
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.0 V / 0.1 V
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range 600 Ω
Resolution 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms Range/Resolution 600.0 Ω / 0.1 Ω
Range/Resolution 6.000 kΩ / 0.001 kΩ
Range/Resolution 60.00 kΩ / 0.01 kΩ
Range/Resolution 600.0 kΩ / 0.1 kΩ
Range/Resolution 6.000 MΩ / 0.001 MΩ
Accuracy 0.9 % + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 1.5 % + 2
Diode Test Range/Resolution  2.000 V / 0.001 V
Accuracy  0.9% + 2
Capacitance Range/Resolution 1000 nF / 1 nF
Range/Resolution 10.00 μF / 0.01 μF
Range/Resolution 100.0 μF / 0.1 μF
Range/Resolution 9999 μF / 1 μF
Range/Resolution 100 μF to 1000 μF
Accuracy 1.9% + 2
Range/Resolution > 1000 μF
Accuracy 5% + 20%
LoZ capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
Temperature2 (Type-K thermocouple) Range/Resolution -40 °C to 400 °C / 0.1 °C
Accuracy 1% + 102
Range/Resolution -40 °F to 752 °F / 0.2 °F
Accuracy 1% + 182
AC μamps true-rms (45 Hz to 500 Hz) Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
DC μamps Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
Hz (V or A input)2 Range/Resolution 99.99 Hz / 0.01 Hz
Range/Resolution 999.99 Hz / 0.1 Hz
Range/Resolution 9.999 Hz / 0.001 Hz
Range/Resolution 50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F

 

Mechanical & General Specifications
Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight 550 g
Warranty 3 years

 

Fluke 62 MAX+ Infrared Thermometer

 

Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62+ MAX <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability of Readings ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA