Type J | -148 to 2102°F (-100 to 1150°C) |
Type K | -148 to 2372°F (-100 to 1300°C) |
Type T | -58 to 752°F (-50 to 400°C) |
Type E | -58 to 1652°F (-50 to 900°C) |
Type R | 32 to 3092°F (0 to 1700°C) |
Type S | 32 to 2732°F (0 to 1500°C) |
RTD (Pt100) | -327 to 1562°F (-200 to 850°C) |
Resolution | 0.1°/1° |
Basic Accuracy | ±0.4% rdg (+1.8°F/+1°C) Types J,K,E,T, Pt100 ±0.5% rdg (+2°F/+1°C) Types R,S |
Datalogging | 20M data records using a 2G SD card |
Dimensions | 7.2 x 2.9 x 1.9" (182 x 73 x 47.5mm) |
Weight | 17.6oz (500g) |
Description
Extech SDL200 4-Channel Datalogging Thermometer
A comprehensive solution for measuring temperature, the Extech SDL200 is capable of carrying out up to four temperature measurements with 6 Thermocouple types (J, K, E, T, R,S) and 2-Channel datalogging with RTD (Pt100Ohm) probes and storeS this information directly onto an SD card for future reference.
It's a tool that's suitable for use either performing standalone single measurements of can alternatively be used to accurately track temperature over a time period by allowing the user to choose between different sampling rate times between a range of 1 to 3600 seconds. The built-in memory of this unit allows it to store up to 99 individual testing records. It also ships as standard with a 2GB SD card which can be used to expand the overall memory of the unit to 20 million records
The Extech SDL200 Comes Supplied With:
- Extech SDL200 4 Channel Datalogging Thermometer
- 6 x AA Batteries
- 4 x General Purpose Type K Bead Wire Temperature Probes
- SD Card
- Hard Carrying Case
Key Features
- 4 channel measurements - allows measurements of four points at the same time
- Displays T1, T2, T3, T4 or differential T1-T2 readings
- Offset adjustment function allows zero function to be used during relative measurements
- 2GB SD card expands memory range up to 20M
- Readings are stamped with time and date for easy reference
- User programmable sampling rate between 1 and 3600 seconds
- MIN/MAX functions
- Data hold function
- Auto power off with disable function
- Built in PC interface
- Compatible with six different thermocouple types (J, K, E, T, R and S)
- Type J measurement range: -148 to 2102°F (-100 to 1150°C)
- Type K measurement range: -148 to 2372°F (-100 to 1300°C)
- Type T measurement range: -58 to 752°F (-50 to 400°C)
- Type E measurement range: -58 to 1652°F (-50 to 900°C)
- Type R measurement range: 32 to 3092°F (0 to 1700°C)
- Type S measurement range: 32 to 2732°F (0 to 1500°C)
ISSWWW and Extech
Since 1971, Extech Instruments has focused on Test and Measurement tools built for the professionals, tradesperson and DIY’ers. Our single source strategy has made us the brand to turn to when it comes to tools that help prevent, identify and troubleshoot problems in a plethora of applications; whether it’s electrical, mechanical, maintenance, safety or environmental applications, our products are trusted by the professionals and are put to the test every day.
Features & Specification
Key Features | Data Logging, ±0.4% rdg (+1.8°F/+1°C) Types J,K,E,T, Pt100, ±0.5% rdg (+2°F/+1°C) Types R,S, 20M data records using a 2G SD card, 6 Thermocouple types, User programmable sampling rate, Displays [T1, T2, T3, T4] or differential [T1-T2] reading | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Stock Status | Next Day Delivery (subject to availability) | ||||||||||||||||||||||||
Manufacturer | Extech | ||||||||||||||||||||||||
Short Description |
|
Delivery
Updated January 2024
Please note, our cut-off time is 2:00pm
Orders requiring calibration
Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.
Bank/Public Holidays
Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scopeof our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.
*UK Mainland (Revised March 2021)
Service | Price |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT | FREE |
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT | £4.95 |
Next WORKING Day (excludes Saturdays, Sundays and public holidays) – UK Mainland only - Zones A & B - ANY order value - Order by 2:00pm | £7.75 |
Saturday ANYTIME Delivery - Order by 2:00pm | £9.95 |
Delivery Surcharges
Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:
- Zones A & B - Mainland delivery rates apply.
- Zone C - Scottish Highlands (Charges are calculated at the checkout).
- Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
- Zone E - Northern Ireland (Charges are calculated at the checkout).
- Zone F - Republic of Ireland (Charges are calculated at the checkout).
Offshore Services
All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.
International delivery
International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk
Export
All export inquiries should be directed to the export division before placement of order.
If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA