Dilog DL9130EVKIT 18th Edition Advanced EV Testing Kit

Special Price £838.80 Regular Price £1,798.80

Voltage

 

 

DL9110

DL9118

DL9120

DL9130EV

Display Range

0V to 440V

0V to 480V

Measuring Range

0V to 440V

0V to 480V

Resolution

1V

1V

Voltage Accuracy

+/- 5% +/- 2digits

+/- 5% +/- 2digits

Frequency Range

45Hz – 65HzV

45.0Hz – 65.0HzV

Frequency Accuracy

+/- 1Hz

+/- 1.0Hz

                                                                            

Continuity

 

 

DL9110

DL9118

DL9120

DL9130EV

Display Range (200mA)

0.01Ω to 200Ω

0.01Ω to 2000Ω

Measuring Range (200mA)

0.10Ω to 200Ω

0.10Ω to 2000Ω

Accuracy

+/- 2% +/- 5 digits

Resolution

0.01Ω to 1.99Ω

2.0Ω to 19.9Ω

20Ω to 200Ω

0.01Ω to 19.99Ω

20.0Ω to 199.9Ω

200Ω to 2000Ω

Test Voltage

>4Vdc >25Vdc Open Circuit

Test Current

>200mA

Display Range (15mA)

 

 

 

0.01Ω to 200Ω

Accuracy

 

 

 

+/- 2% +/- 5 digits

Resolution

 

 

 

0.01Ω to 19.99Ω

20.0Ω to 199.9Ω

 

 

 

 

>4Vdc >25Vdc Open Circuit

 

 

 

 

>15mA

Compliance

IEC61557-4 and IEC61557-10

 

Insulation

 

 

 

 

DL9110

DL9118

DL9120

DL9130EV

Display Range

0.01MΩ to 200MΩ

Display Range

0.05MΩ to 200MΩ

Accuracy

+/-5% +/-5 digits

Resolution

0.01MΩ to 1.99MΩ

2.0MΩ to 19.9MΩ

20MΩ to 200MΩ

Alarm Warning

<1MΩ Audible

<1MΩ Screen & Audible

Test Voltage

250/500

250/500/1000V

Test Voltage Specification

-0% +20% (open circuit)

Test Current

1mA into UN (1000Ω/V)

Compliance

IEC61557-2 and IEC61557-10

               

 

No Trip Loop Impedance

 

 

DL9110

DL9118

DL9120

DL9130EV

Supply voltage

195-253V, 45Hz – 65Hz

Display Range

0.01Ω to 2000Ω

Measuring Range

1.00 to 1999Ω (non-trip)

Accuracy

+/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)

Resolution

0.01Ω to 1.99Ω

2.0Ω to 19.9Ω

20Ω to 2000Ω

0.01Ω to 9.99Ω

10.0Ω to 99.9Ω

100Ω to 2000Ω

Test Current

<15mA RMS

 

High Current Loop Impedance

 

 

DL9110

DL9118

DL9120

DL9130EV

Supply voltage

195-253V, 45Hz – 65Hz

Display Range

0.01Ω to 2000Ω

Measuring Range

0.10Ω to 1999Ω (high current)

Accuracy

+/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)

Resolution

0.01Ω to 1.99Ω

2.0Ω to 19.9Ω

20Ω to 2000Ω

0.01Ω to 9.99Ω

10.0Ω to 99.9Ω

100Ω to 2000Ω

Test Current

3A RMS

 

Loop Test PFC Measurement

 

 

DL9110

DL9118

DL9120

DL9130EV

Display Range

1A to 26kA

0.1A to 26.0kA

Accuracy

+/-5%  +/-5 digits

+/-5%  +/-5 digits

Resolution

1A to 999A

1kA to 26kA

0.1A to 999.9A

1.0kA to 26.0kA

 

High Current Line Impedance

 

 

 

DL9110

DL9118

DL9120

DL9130EV

Display Range

0.01Ω to 2000Ω

0.01Ω to 2000Ω

Measuring Range

0.10Ω to 2000Ω

0.10Ω to 2000Ω

Accuracy

+/-5% +/-5 digits

+/-5% +/-5 digits

Resolution

0.01Ω to 1.99Ω

2.0Ω to 19.9Ω

20Ω to 2000Ω

0.01Ω to 9.99Ω

10.0Ω to 99.9Ω

100Ω to 2000Ω

Supply Voltages

195V – 253V

 

195V – 253V

328V – 440V

195V – 253V

328V – 480V

Test Current

3A RMS Peak

           

 

Line Test PSC Measurement

 

 

DL9110

DL9118

DL9120

DL9130EV

Range

1A to 26kA

0.1A to 26.0kA

Accuracy

+/-5%  +/-5 digits

+/-5%  +/-5 digits

Resolution

1A to 999A

1kA to 26kA

0.1A to 999.9A

1.0kA to 26.0kA

 

RCD Trip Time Test

 

 

DL9110

DL9118

DL9120

DL9130EV

Supply Voltages

195-253V, 45Hz – 65Hz

RCD Types

AC, A & Selective

AC, A, B & Selective

Nominal Test Current

10mA/30mA/100mA ( ½ , 1, 5 I∆n)

300mA/500mA ( ½, 1 I∆n)

10mA/30mA/100mA ( ½ , 1, 5 I∆n)

300mA/500mA ( ½, 1 I∆n)

Variable Mode

Variable RCD Test

 

1mA – 500mA

Test Current Accuracy

-0% +10% at I∆n and 5I∆n

-0% +10% at ½ I∆n

Trip Time Ranges

0 to 2000ms ½ I∆n

0ms - 300ms I∆n general

0ms - 500ms I∆n selective

0 to 40ms 5 I∆n

Trip Time Accuracy

+/- 5% +/- 2 digits

Nominal Test Current

10mA/30mA/100mA ( ½ , 1, 5 I∆n)

300mA/500mA ( ½, 1 I∆n)

Compliance

IEC61557-6 and IEC61557-10

 

RDC-DD Trip Time Test

 

 

DL9110

DL9118

DL9120

DL9130EV

Supply Voltages

 

195-253V, 45Hz – 65Hz

Current Type

 

DC

Nominal Test Current

 

6mA

Test Current Accuracy

 

-0% +10%

Trip Time Ranges

 

0 to 10000 I∆n

Trip Time Accuracy

 

+/- 5% +/- 2 digits

Ramp Test Current Range

 

2mA – 10mA

Compliance

IEC61557-6 and IEC61557-10

 

RCD (Ramp) Trip Current Test

 

Range

0.5 I∆n to 1.1 I∆n

Range (6mA DC)

 

0.1mA to 10mA

(over 30 seconds)

Accuracy

+/-5% of the expected current

Step Size

0.1*∆n

Step duration

300ms

Compliance

IEC61557-6 and IEC61557-10

 

Additional Date

 

 

 

DL9110

DL9118

DL9120

DL9130EV

Weight

1360g

Dimensions 

Width 236mm

Depth 130mm

Height 91mm

DL911x Boxed

3045g

3075g

3045g

3075g

DL911x Boxed Dimensions

Width 380mm

Depth 195mm

Height 250mm

EAN Barcode

5060082543463

5060082543449

5060082544156

5060082544163

             

 

Box Contents

 

 

DL9110

DL9118

DL9120

DL9130EV

Multifunction Tester

Multifunction Tester

Padded neck strap

Padded neck strap

Professional toolbox style carry case

Professional toolbox style carry case

Mains lead

Mains lead

1.2M black test lead

1.2M Blue test lead

1.2M red test lead

1.2M red test lead

1.2M green test lead

1.2M green test lead

Black crocodile clip

Blue crocodile clip

Red crocodile clip

Red crocodile clip

Green crocodile clip

Green crocodile clip

MN1500 (AA) 1.5v Batteries x 6

MN1500 (AA) 1.5v Batteries x 6

Operating Instruction Manual

Operating Instruction Manual

Calibration certificate

Calibration certificate

(Optional)

Remote Test Probe

(Optional)

Remote Test Probe

         

 

DL9100 Series Spares and Accessories

 

 

DL9110

DL9118

DL9120

DL9130EV

LS3W9073 – Red/Black/Green 3 wire lead set c/w croc clips and probes

LS3W9100 – Red/Blue/Green 3 wire lead set c/w croc clips and probes

ML9073 – Red/Black/Green 13A to 4mm mains lead

ML9100 – Red/Blue/Green 13A to 4mm mains lead

RP9100 – Remote Test Probe (suitable for DL9100 Series testers)

CCDL9100 – Toolbox Style Carry Case

AF27B – 1.6A 1000V HRC FF Fuse

????? – 200mA …………

 

 

 

 

 

 

 

 

         

 

Environmental Conditions

The DL9120 / DL9130EV has been designed to perform tests and measurements in a dry indoor environment.

  • Operating Altitude 0 to 2000 metres.
  • Overvoltage category IEC 60664/IEC 61010, 300V Category III.
  • Pollution degree 2 according to IEC 61010-1.
  • Protective system IP40 according to IEC 60529.
  • Electromagnetic compatibility (EMC). Interference immunity and emitted interference conforming to IEC 61326-1.
  • Operating temperature range of 0°C to 40°C.
  • Operating humidity up to 75% without condensation.

The DL9120 / DL9130EV can be stored at any temperature in the range -25°C to +65° The batteries should be taken out of the instrument for storage.
For help or advice on Service and Calibration contact:

Service Department

Di-Log Test Equipment

28 Wheel Forge Way

Trafford Park

Manchester

M17 1EH

UK

Tel: 0161 877 0322

Fax: 0161 877 1614

email: support@dilog.co.uk

web: www.dilog.co.uk

UKAS Cal Cert Included

Description

Dilog DL9130EVKIT Complete 18th Edition Advanced EV Testing Kit

*Important Calibration Information:

This instrument comes complete with a manufacturer’s UKAS calibration certificate.
Please be aware that these certificates are generic and may also be time lapsed.

If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.

 

18th Edition Complete EV Kit with DLEV1 EVSE Charge Station Adaptor

The Di-LOG DL9130EVKIT Complete Test Kit has been explicitly designed for service engineers that offer EV installation as part of their testing portfolio. The DL9130EVKIT Complete kit includes Di-LOG’s latest EV Multifunction Tester, the DL9130EV, along with the DLEV1 EVSE Charge Station Adaptor.

The DL9130EV has several exciting new features critical to the safe verification of EVSE Charge Station Installations.  Including a 6mA pure DC test for RDC-DD verification which can be combined with a full Auto EV testing sequence.  The Auto EV sequence feature simply varifies the DC protection provided by the EV charger, along with the Type A RCD protection provided by the sub-distribution board.


 

Kit Key Features:

  • 6ma RDC-DD Pure DC Test
  • Auto EV Test Sequence
  • Auto Start Loop & Continuity tests
  • Type AC, A, B & Selective (S) RCD Testing
  • Rmax & Zmax
  • Variable RCD Test
  • Colour LCD display with colour change feature
  • Proximity Pilot (PP) State 13, 20, 32 & 63A
  • Control Pilot (CP) State A, B, C & D
  • Error including – PE Pre-Test, CP Error “E” & PE Error
  • Type 1 & Type 2 Charge Plugs supplied
  • Supplied with a UKAS Calibration Certificate fully traceable to national standards (DL9130EV)


Additional Features:

  • 6mA pure DC test for RDC-DD verification and a full Auto EV testing sequence for verifying the DC protection provided by the EV charger, along with the Type A RCD protection
  • Loop Impedance/PSCC – Unique auto start RCD-LOC XLT loop test principle will not trip any RCD or RCBO
  • 2/3 wire high current loop with intelligent detection identifying if the user is conducting a 2 wire or 3 wire Loop/PSCC measurement without the need for selection
  • RGB colour changing screen visually indicating potential pass/fail conditions
  • Phase to Phase Loop with Phase Rotation Test – will indicate the correct phase sequence
  • Continuity test – with auto start & null facility to zero out lead resistance
  • Auto RCD testing – Trip time, trip current, auto test and ramp current
  • Type AC, A, B & Time Delayed RCDs (S)
  • Insulation measurement – with 250, 500 & 1000V test voltages
  • Phase Rotation Test – will indicate the correct phase sequence
  • Integrated socket polarity test
  • Fully protected against damage when accidentally connected across phases
  • Proximity Pilot (PP) State to simulate the charge lead resistances related to charging lead current limits
  • Control Pilot (CP) State to simulate the communication signal emitted from an Electric Vehicle to indicate its readiness to receive a charge.


Brand New Features

A brand-new feature explicitly added to the DL9130EV is Rmax.  This brand-new concept will automatically capture the maximum R1+R2/R2 continuity test reading which will register the result on the secondary display for recording once testing is complete. In addition, Di-LOG has added the Zmax feature.

Type B RCD Testing

Type B RCDs are becoming more frequent in PV and EV installations, so it is vital that when needed, your multifunction tester can perform a Pure DC RCD test.  A variable RCD feature has also been added to the DL9120 & DL9130EV enabling the user to dial in bespoke mA values when the need arises.

Intelligent User Features at the press of a button

With a brand new RGB colour-changing screen that visually indicates potential pass/fail conditions, the DL9130EV offers intelligent user features. One of our intelligent features is Zmax, this will record the maximum Zs test recorded during a recording session. A fully automated Continuity & Earth Loop Auto Start with a secondary display to capture the recorded results. Never seen before on a multifunction tester, is the high current loop with intelligent detection identifying if the user is conducting a 2 wire or 3 wire Loop/PSCC measurement without the need for selection.


EVSE Test Adaptor Kit

The DLEV1 is a universal EVSE Charge Station Adaptor Kit that will simulate the Proximity Pilot (PP) States and Control Pilot (CP) States required to energise a free-standing or wall-mounted EV charger. Supplied with a type 1 and type 2 connector plug specifically designed for testing, the DLEV1 kit will also simulate PE Pre-test, CP Error “E” and PE Error with the added feature of CP signal output and load connection.

The DLEV1 has a 13A socket for MFT mains lead or can be used for inline load connection. In addition to this, there are also 4mm input terminals for single or 3-phase connections.

The DL9130EVKIT MFT Test Kit offers incredible value for a feature-packed MFT meeting all the safety and performance requirements of BS EN 61557.


About Di-Log

Di-Log Test Equipment offers a comprehensive range of test equipment from a voltage indicator to 18th Edition and Thermal Imaging to portable  appliance testing kits.  All Di-Log instruments are designed and manufactured to the highest quality specification and you can be assured that all manufacturing processes adhere to internationally recognised standards. Di-Log instruments are accurate, safe and rugged – you won’t find a better balance between cost and functionality.

Features & Specification

More Information
Key Features Comes with UKAS calibration certificate, 6ma RDC-DD Pure DC Test, Auto EV Test Sequence, Auto Start Loop & Continuity tests, Rmax & Zmax, Error including – PE Pre-Test CP Error “E” & PE Error, Type 1 & Type 2 Charge Plugs supplied
Product Stock Status Next Day Delivery (subject to availability)
Manufacturer Dilog
Short Description

Voltage

 

 

DL9110

DL9118

DL9120

DL9130EV

Display Range

0V to 440V

0V to 480V

Measuring Range

0V to 440V

0V to 480V

Resolution

1V

1V

Voltage Accuracy

+/- 5% +/- 2digits

+/- 5% +/- 2digits

Frequency Range

45Hz – 65HzV

45.0Hz – 65.0HzV

Frequency Accuracy

+/- 1Hz

+/- 1.0Hz

                                                                            

Continuity

 

 

DL9110

DL9118

DL9120

DL9130EV

Display Range (200mA)

0.01Ω to 200Ω

0.01Ω to 2000Ω

Measuring Range (200mA)

0.10Ω to 200Ω

0.10Ω to 2000Ω

Accuracy

+/- 2% +/- 5 digits

Resolution

0.01Ω to 1.99Ω

2.0Ω to 19.9Ω

20Ω to 200Ω

0.01Ω to 19.99Ω

20.0Ω to 199.9Ω

200Ω to 2000Ω

Test Voltage

>4Vdc >25Vdc Open Circuit

Test Current

>200mA

Display Range (15mA)

 

 

 

0.01Ω to 200Ω

Accuracy

 

 

 

+/- 2% +/- 5 digits

Resolution

 

 

 

0.01Ω to 19.99Ω

20.0Ω to 199.9Ω

 

 

 

 

>4Vdc >25Vdc Open Circuit

 

 

 

 

>15mA

Compliance

IEC61557-4 and IEC61557-10

 

Insulation

 

 

 

 

DL9110

DL9118

DL9120

DL9130EV

Display Range

0.01MΩ to 200MΩ

Display Range

0.05MΩ to 200MΩ

Accuracy

+/-5% +/-5 digits

Resolution

0.01MΩ to 1.99MΩ

2.0MΩ to 19.9MΩ

20MΩ to 200MΩ

Alarm Warning

<1MΩ Audible

<1MΩ Screen & Audible

Test Voltage

250/500

250/500/1000V

Test Voltage Specification

-0% +20% (open circuit)

Test Current

1mA into UN (1000Ω/V)

Compliance

IEC61557-2 and IEC61557-10

               

 

No Trip Loop Impedance

 

 

DL9110

DL9118

DL9120

DL9130EV

Supply voltage

195-253V, 45Hz – 65Hz

Display Range

0.01Ω to 2000Ω

Measuring Range

1.00 to 1999Ω (non-trip)

Accuracy

+/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)

Resolution

0.01Ω to 1.99Ω

2.0Ω to 19.9Ω

20Ω to 2000Ω

0.01Ω to 9.99Ω

10.0Ω to 99.9Ω

100Ω to 2000Ω

Test Current

<15mA RMS

 

High Current Loop Impedance

 

 

DL9110

DL9118

DL9120

DL9130EV

Supply voltage

195-253V, 45Hz – 65Hz

Display Range

0.01Ω to 2000Ω

Measuring Range

0.10Ω to 1999Ω (high current)

Accuracy

+/-5% +/-12 digits (to 20Ω) +/-5% +/-5 digits (to 2000Ω)

Resolution

0.01Ω to 1.99Ω

2.0Ω to 19.9Ω

20Ω to 2000Ω

0.01Ω to 9.99Ω

10.0Ω to 99.9Ω

100Ω to 2000Ω

Test Current

3A RMS

 

Loop Test PFC Measurement

 

 

DL9110

DL9118

DL9120

DL9130EV

Display Range

1A to 26kA

0.1A to 26.0kA

Accuracy

+/-5%  +/-5 digits

+/-5%  +/-5 digits

Resolution

1A to 999A

1kA to 26kA

0.1A to 999.9A

1.0kA to 26.0kA

 

High Current Line Impedance

 

 

 

DL9110

DL9118

DL9120

DL9130EV

Display Range

0.01Ω to 2000Ω

0.01Ω to 2000Ω

Measuring Range

0.10Ω to 2000Ω

0.10Ω to 2000Ω

Accuracy

+/-5% +/-5 digits

+/-5% +/-5 digits

Resolution

0.01Ω to 1.99Ω

2.0Ω to 19.9Ω

20Ω to 2000Ω

0.01Ω to 9.99Ω

10.0Ω to 99.9Ω

100Ω to 2000Ω

Supply Voltages

195V – 253V

 

195V – 253V

328V – 440V

195V – 253V

328V – 480V

Test Current

3A RMS Peak

           

 

Line Test PSC Measurement

 

 

DL9110

DL9118

DL9120

DL9130EV

Range

1A to 26kA

0.1A to 26.0kA

Accuracy

+/-5%  +/-5 digits

+/-5%  +/-5 digits

Resolution

1A to 999A

1kA to 26kA

0.1A to 999.9A

1.0kA to 26.0kA

 

RCD Trip Time Test

 

 

DL9110

DL9118

DL9120

DL9130EV

Supply Voltages

195-253V, 45Hz – 65Hz

RCD Types

AC, A & Selective

AC, A, B & Selective

Nominal Test Current

10mA/30mA/100mA ( ½ , 1, 5 I∆n)

300mA/500mA ( ½, 1 I∆n)

10mA/30mA/100mA ( ½ , 1, 5 I∆n)

300mA/500mA ( ½, 1 I∆n)

Variable Mode

Variable RCD Test

 

1mA – 500mA

Test Current Accuracy

-0% +10% at I∆n and 5I∆n

-0% +10% at ½ I∆n

Trip Time Ranges

0 to 2000ms ½ I∆n

0ms - 300ms I∆n general

0ms - 500ms I∆n selective

0 to 40ms 5 I∆n

Trip Time Accuracy

+/- 5% +/- 2 digits

Nominal Test Current

10mA/30mA/100mA ( ½ , 1, 5 I∆n)

300mA/500mA ( ½, 1 I∆n)

Compliance

IEC61557-6 and IEC61557-10

 

RDC-DD Trip Time Test

 

 

DL9110

DL9118

DL9120

DL9130EV

Supply Voltages

 

195-253V, 45Hz – 65Hz

Current Type

 

DC

Nominal Test Current

 

6mA

Test Current Accuracy

 

-0% +10%

Trip Time Ranges

 

0 to 10000 I∆n

Trip Time Accuracy

 

+/- 5% +/- 2 digits

Ramp Test Current Range

 

2mA – 10mA

Compliance

IEC61557-6 and IEC61557-10

 

RCD (Ramp) Trip Current Test

 

Range

0.5 I∆n to 1.1 I∆n

Range (6mA DC)

 

0.1mA to 10mA

(over 30 seconds)

Accuracy

+/-5% of the expected current

Step Size

0.1*∆n

Step duration

300ms

Compliance

IEC61557-6 and IEC61557-10

 

Additional Date

 

 

 

DL9110

DL9118

DL9120

DL9130EV

Weight

1360g

Dimensions 

Width 236mm

Depth 130mm

Height 91mm

DL911x Boxed

3045g

3075g

3045g

3075g

DL911x Boxed Dimensions

Width 380mm

Depth 195mm

Height 250mm

EAN Barcode

5060082543463

5060082543449

5060082544156

5060082544163

             

 

Box Contents

 

 

DL9110

DL9118

DL9120

DL9130EV

Multifunction Tester

Multifunction Tester

Padded neck strap

Padded neck strap

Professional toolbox style carry case

Professional toolbox style carry case

Mains lead

Mains lead

1.2M black test lead

1.2M Blue test lead

1.2M red test lead

1.2M red test lead

1.2M green test lead

1.2M green test lead

Black crocodile clip

Blue crocodile clip

Red crocodile clip

Red crocodile clip

Green crocodile clip

Green crocodile clip

MN1500 (AA) 1.5v Batteries x 6

MN1500 (AA) 1.5v Batteries x 6

Operating Instruction Manual

Operating Instruction Manual

Calibration certificate

Calibration certificate

(Optional)

Remote Test Probe

(Optional)

Remote Test Probe

         

 

DL9100 Series Spares and Accessories

 

 

DL9110

DL9118

DL9120

DL9130EV

LS3W9073 – Red/Black/Green 3 wire lead set c/w croc clips and probes

LS3W9100 – Red/Blue/Green 3 wire lead set c/w croc clips and probes

ML9073 – Red/Black/Green 13A to 4mm mains lead

ML9100 – Red/Blue/Green 13A to 4mm mains lead

RP9100 – Remote Test Probe (suitable for DL9100 Series testers)

CCDL9100 – Toolbox Style Carry Case

AF27B – 1.6A 1000V HRC FF Fuse

????? – 200mA …………

 

 

 

 

 

 

 

 

         

 

Environmental Conditions

The DL9120 / DL9130EV has been designed to perform tests and measurements in a dry indoor environment.

  • Operating Altitude 0 to 2000 metres.
  • Overvoltage category IEC 60664/IEC 61010, 300V Category III.
  • Pollution degree 2 according to IEC 61010-1.
  • Protective system IP40 according to IEC 60529.
  • Electromagnetic compatibility (EMC). Interference immunity and emitted interference conforming to IEC 61326-1.
  • Operating temperature range of 0°C to 40°C.
  • Operating humidity up to 75% without condensation.

The DL9120 / DL9130EV can be stored at any temperature in the range -25°C to +65° The batteries should be taken out of the instrument for storage.
For help or advice on Service and Calibration contact:

Service Department

Di-Log Test Equipment

28 Wheel Forge Way

Trafford Park

Manchester

M17 1EH

UK

Tel: 0161 877 0322

Fax: 0161 877 1614

email: support@dilog.co.uk

web: www.dilog.co.uk

Delivery

Updated January 2024

Please note, our cut-off time is 2:00pm

Orders requiring calibration 

Whilst we take the greatest care to get all orders dispatched and delivered to you in the stated time frame, orders received PM and requiring calibration may on occasion miss dispatch that day, according to the complexity of the calibration.
Be assured they will ship on the next dispatch this in most cases should not add more than 24 hours to your delivery.

Bank/Public Holidays

Predicted delivery times are based on regular trading days Monday to Friday. Public holidays, bank holidays and weekends are outside the usual scope
of our dispatch and subject to activities/holidays of our carriers and therefore may incur additional days lead time to your order.

*UK Mainland (Revised March 2021)

Service Price
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value OVER £75.00 ex VAT FREE
Standard FREE 2-3 Day Courier Delivery – UK Mainland only - Zones A & B - Order value UNDER £75.00 ex VAT £4.95
Next WORKING Day (excludes Saturdays, Sundays and public holidays)  – UK Mainland only - Zones A & B  - ANY order value - Order by 2:00pm £7.75
Saturday ANYTIME Delivery - Order by 2:00pm £9.95
 

 

 

 

 

Delivery Surcharges

Because of the high cost of carriage, we regretfully need to apply a surcharge on all deliveries made in the following regions:

  • Zones A & B  - Mainland delivery rates apply. 
  • Zone C - Scottish Highlands (Charges are calculated at the checkout).
  • Zone D - Outer Hebrides, Orkney Isles, Shetland Isles, Isle of Man, Scilly Isles, and Channel Islands (Charges are calculated at the checkout).
  • Zone E - Northern Ireland (Charges are calculated at the checkout).
  • Zone F - Republic of Ireland (Charges are calculated at the checkout).

Offshore Services

All offshore deliveries are a 3-4 day service as standard. This includes Channel Islands, Northern & Southern Ireland, Scottish Islands, Isle of Man and the Scilly Isles.

International delivery

International delivery charges are automatically added to your order at the checkout. For any questions regarding international deliveries please contact us at sales@isswww.co.uk

Export 

All export inquiries should be directed to the export division before placement of order.

If no shipping option is available to your selected country please call us FREE on 0800 0224 060 to discuss your requirements.
All stated prices are subject to VAT at the current rate where applicable.
E&OA